HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

GB/T 22901-2008 English PDF

US$209.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 22901-2008: Paper and board -- Determination of air permeance (medium range) -- General method
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 22901-2008English209 Add to Cart 3 days [Need to translate] Paper and board -- Determination of air permeance (medium range) -- General method Valid GB/T 22901-2008

PDF similar to GB/T 22901-2008


Standard similar to GB/T 22901-2008

GB/T 24328.3   GB/T 27741   GB/T 31905   GB/T 22904   GB/T 22894   GB/T 22893   

Basic data

Standard ID GB/T 22901-2008 (GB/T22901-2008)
Description (Translated English) Paper and board -- Determination of air permeance (medium range) -- General method
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard Y30
Classification of International Standard 85-010
Word Count Estimation 9,965
Date of Issue 2008-12-30
Date of Implementation 2009-09-01
Quoted Standard GB/T 450; GB/T 10739
Adopted Standard ISO 5636-1-1984, MOD
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the determination of air permeability of paper and paperboard (medium range) of the basic technical requirements for using the instruments and the general method of operation. This standard applies to air permeability in 1X10-2 ��m/(Pas) ~ 1X10-2��m/(Pas) paper and cardboard in the range. This standard does not apply to the rough surface of paper and paperboard, such as crepe paper and cardboard, because this type of paper is not easy to grip securely, easily lead to leaks.

GB/T 22901-2008: Paper and board -- Determination of air permeance (medium range) -- General method


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Paper and board. Determination of air permeance (medium range). General method ICS 85-010 Y30 National Standards of People's Republic of China Paper and board - Determination of air permeability (medium range) General Method [ISO 5636-1. 1984, Paperandboard- Determinationofairpermeance (mediumrange) - Part 1. GeneralmethodMOD] Posted 2008-12-30 2009-09-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

This revised standard adopts ISO 5636-1. 1984 "Paper and board Determination of air permeability (medium range) - Part 1. General Method" (In English). Appendix B gives a list of the control of the national standards with international standards provisions. Appendix C gives the list of the national standards with international standards and technical reasons for the differences. The Standard Appendix A, Appendix B and Appendix C are informative appendices. The standard proposed by China National Light Industry Council. This standard by the National Standardization Technical Committee of the paper industry. This standard was drafted. People's Republic of China Shanghai Entry-Exit Inspection and Quarantine Bureau, China Pulp and Paper Research Institute, the national paper quality supervision Governor Inspection Center. The main drafters of this standard. Zhu Hongkun, Jiang Wei, ZHANG Xiaorong, Li Hong, Chen Xiang, Wanghai Ting, Li Wei. Paper and board - Determination of air permeability (medium range) General Method

1 Scope

This standard specifies the determination of paper and paperboard air permeability (medium range) instrument used by the basic technical requirements and general method of operation. This standard applies to air permeability of 1 × 10-2μm/(Pa · s) ~ 1 × 10 Paper and cardboard inner μm/(Pa · s) range. This standard does not apply to the surface roughness of paper and board, such as crepe paper and corrugated paper, because such paper is not easy to grip firmly, easily lead to leaks.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 450 and take samples to an aspect of paper and paperboard samples, positive and negative determination (GB/T 450-2008, ISO 186. 2002, MOD) GB/T 10739 paper, paperboard and pulp sample processing and testing standard atmospheric conditions (GB/T 10739-2002, eqv ISO 187. 1990)

3 Terms and Definitions

The following terms and definitions apply to this standard. 3.1 Under pressure units in the average air flow per unit time through unit area of \u200b\u200bspecimen, expressed in microns per pascal second [1mL/(m2 · Pa · s) = 1μm/(Pa · s)]. Principle 4 The specimen is clamped between a circular seal pad and a known diameter of the ring plane, suffered side air sample test zone pressure Force of atmospheric pressure on both sides of the specimen during testing has been very small, but very stable. Measured within the prescribed period of time through the test area air flow. Note. When using Gurley tester, stress testing procedure will be applied with the buoyancy cylinder change, but this change is reproducible.

5 Instruments

In addition to meeting the air permeability of 5.1 other relevant national standards corresponding part of the detailed requirements, the instrument should also meet the following requirements. a) Determination of the accuracy of the volume of the measured value ± 2%, the accuracy of the measurement time for the measured value ± 1%; b) measuring the air flow rate accuracy of ± 5% for the measured values. Display Value 5.2 Sample required between 0.7kPa ~ 3.0kPa, the pressure on both sides of the initial sample shall be ± 2%, and its measurement process Error should not exceed 5%. 5.3 specimen test area shall not be less than 6cm2, 10cm2 of the test area is recommended. Error test area should be controlled in size Within the range of ± 2%. 5.4 When water is used as the replacement medium penetrating air flow direction of the sample should never make prior contact with water. Sealing is recommended to check the instrument

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 22901-2008_English be delivered?

Answer: Upon your order, we will start to translate GB/T 22901-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 22901-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 22901-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.