US$1059.00 ยท In stock Delivery: <= 7 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 22264.8-2022: Mounted digital display electric measuring instruments - Part 8: Test methods Status: Valid GB/T 22264.8: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 22264.8-2022 | English | 1059 |
Add to Cart
|
7 days [Need to translate]
|
Mounted digital display electric measuring instruments - Part 8: Test methods
| Valid |
GB/T 22264.8-2022
|
| GB/T 22264.8-2009 | English | 148 |
Add to Cart
|
1 days [Need to translate]
|
Mounted digital display electric measuring instruments -- Part 8: Recommended test methods
| Obsolete |
GB/T 22264.8-2009
|
PDF similar to GB/T 22264.8-2022
Basic data | Standard ID | GB/T 22264.8-2022 (GB/T22264.8-2022) | | Description (Translated English) | Mounted digital display electric measuring instruments - Part 8: Test methods | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | N23 | | Classification of International Standard | 17.220.20 | | Word Count Estimation | 54,532 | | Date of Issue | 2022-12-30 | | Date of Implementation | 2023-07-01 | | Older Standard (superseded by this standard) | GB/T 22264.8-2009 | | Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration |
GB/T 22264.8-2022: Mounted digital display electric measuring instruments - Part 8: Test methods---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS 17.220.20
CCSN23
National Standards of People's Republic of China
Replace GB/T 22264.8-2009
Installed digital display electrical measuring instrument
Part 8.Test methods
Posted on 2022-12-30
2023-07-01 implementation
State Administration for Market Regulation
Released by the National Standardization Management Committee
table of contents
Preface III
Introduction V
1 Scope 1
2 Normative references 1
3 Terms and Definitions 2
4 General test conditions 3
4.1 Standard power value 3
4.2 Reference conditions 3
4.3 Thermal stabilization 3
4.4 Preprocessing 3
4.5 Measuring equipment error 3
4.6 Multiphase test 3
4.7 Multi-measurement range and multi-function instrument 3
4.8 Test leads 3
5 Measuring equipment 3
6 sample 4
7 Test steps and test data processing 4
7.1 Basic error 4
7.2 Change limit 6
7.3 Safety requirements 19
7.4 Electrical requirements 23
7.5 Accuracy performance requirements 33
7.6 Electromagnetic Compatibility 35
7.7 Structural requirements 40
7.8 Climate impacts 42
7.9 Reliability 43
7.10 Special functional requirements 43
7.11 Information, general signs and symbols 44
8 Test items and recommended sequence 44
9 Test report 45
Reference 47
Fig.1 Measuring voltage circuit Active power consumption circuit Fig.25
Fig. 2 Measuring the active power consumption circuit of the auxiliary power supply circuit Fig. 25
Figure 3 Series mode anti-interference ability test circuit Figure 28
Figure 4 AC common mode anti-interference ability test circuit Figure 29
Figure 5 DC common mode anti-interference ability test circuit Figure 30
Figure 6 Open circuit voltage and current measurement wiring diagram of insulation resistance meter 31
Figure 7 Output voltage measurement wiring diagram of insulation resistance meter 32
Table 1 The main measuring equipment that should be equipped3
Table 2 Time setting for short-term supply voltage changes 39
Table 3 Test items and recommended sequence 44
foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1.Structure and Drafting Rules for Standardization Documents"
drafting.
This document is part 8 of GB/T 22264 "Mounted Digital Display Electrical Measuring Instruments". GB/T 22264 has issued the following
part.
--- Part 1.Definitions and general requirements;
--- Part 2.Special requirements for ammeters and voltmeters;
--- Part 3.Special requirements for power meters and reactive power meters;
--- Part 4.Special requirements for frequency tables;
--- Part 5.Particular requirements for phase meters and power factor meters;
--- Part 6.Special requirements for insulation resistance meters;
--- Part 7.Special requirements for multi-function instruments;
--- Part 8.Test methods.
This document replaces GB/T 22264.8-2009 "Mounted digital display electrical measuring instruments - Part 8.Recommended test methods", and
Compared with GB/T 22264.8-2009, except for structural adjustment and editorial changes, the main technical changes are as follows.
--- Changed the scope and added "This document is applicable to newly manufactured DC 750V and AC 690V and below, the nominal frequency is
Measuring ammeter and voltmeter, wattmeter and reactive power meter, frequency meter, phase meter in 50Hz or 60Hz power distribution system
and power factor meter, insulation resistance meter, and any combination of two or more multifunctional instruments, also suitable for analog/digital
Digital display portion of a dual display electrical measuring instrument. "(see Chapter 1, see Chapter 1 of the.2009 edition);
--- Increased the standard power value (see 4.1);
---Change "change caused by ambient humidity" to "change caused by relative humidity (no condensation)" and "humidity setting 93%"
For "humidity setting 95%" (see 7.2.2, 5.3 of the.2009 edition);
--- Merge "change amount caused by auxiliary power supply voltage (or battery voltage)" and "change amount caused by auxiliary power supply frequency" into "auxiliary
In "power supply", add "AC power supply waveform", "DC power supply voltage" and "ripple of DC power supply voltage" (see 7.2.8,.2009 edition
5.8, 5.9);
---Change "80% full scale" in "the change caused by the measured voltage component" to "the lower limit of the measurement range plus 80% of the range",
"Voltage to the lower limit of its nominal use range" is changed to "voltage to 90% of the lower limit of the nominal voltage or reference voltage range",
"Voltage to the upper limit of its nominal use range" was changed to "voltage to 110% of the upper limit of the nominal voltage or reference voltage range"
(see 7.2.9, 5.11 of the.2009 edition);
---Change "80% full scale" in "the change caused by the measured current component" to "the lower limit of the measurement range plus 80% of the range",
"Current to the lower limit of its nominal use range" is changed to "Current to 10% of the nominal current value or 90% of the lower limit of the reference current range
Value", "current to the upper limit of its nominal use range" changed to "current to 120% of the nominal current value or the upper limit of the reference current range
110% current value" (see 7.2.10, 5.12 of the.2009 edition);
--- Refinement of safety requirements (see 7.3, 7.5, Chapter 9 of 7.3,.2009 edition);
--- Changed the limit value imposed by the temperature rise voltage/current circuit (see 7.4.2, 6.8 of the.2009 edition);
--- Added "data input interface" and "protection of input and output interfaces" (see 7.4.5);
--- Added "response time of insulation resistance meter used in IT system" (see 7.4.7.3);
--- Added "measurement voltage peak value of insulation resistance meter used in IT system" (see 7.4.14);
--- Added "measurement current peak value of insulation resistance meter used in IT system" (see 7.4.15);
--- Added general requirements for structure (see 7.7.1);
--- Changed the shock test clauses, and summarized the vibration test and shock test clauses to the influence of mechanical force (see 7.7.5,.2009
version 7.1, 7.2);
--- Deleted the operating temperature limit (see 6.9 of the.2009 edition);
--- Changed the terms of high temperature, low temperature and alternating damp heat (see 7.8.1, 7.8.2, 7.8.3, 8.1, 8.2, 8.3 of the.2009 edition);
--- Changed the "average life" and changed "average life" to "reliability" (see Chapter 11 of 7.9,.2009 edition);
--- Added special functional requirements (see 7.10);
--- Added information, general signs and symbols (see 7.11);
--- Added test items and recommended sequence (see Chapter 8);
--- Deleted the schematic diagram of the DC electromagnet (see Appendix A of the.2009 edition).
Please note that some contents of this document may refer to patents. The issuing agency of this document assumes no responsibility for identifying patents.
This document is proposed by China Machinery Industry Federation.
This document is under the jurisdiction of the National Standardization Technical Committee for Electrical Instrumentation (SAC/TC104).
This document is drafted by. Harbin Institute of Electrical Instrumentation Co., Ltd., China Electrical Instrumentation Quality Supervision and Inspection Center, Zhejiang Zhengzhou
Taiwulian Technology Co., Ltd., Zhejiang Institute of Metrology, Ningbo Canaan Smart Electric Co., Ltd., Wenzhou Metrology Research
Institute, Shanghai Complee Instrument Co., Ltd., State Grid Hunan Electric Power Co., Ltd. Power Supply Service Center (Metering Center), State Grid Shandong Electric Power Company
Marketing Service Center (Metering Center), State Grid Shandong Electric Power Company Electric Power Research Institute, Zhejiang Tianzheng Electric Co., Ltd., Holley
Technology Co., Ltd., Zhejiang Wansheng Intelligent Technology Co., Ltd., Shandong Huake Information Technology Co., Ltd., State Grid Chongqing Electric Power Company
Company Marketing Service Center, Jiangsu Sfeier Electric Co., Ltd., Delixi Group Instrument Co., Ltd., Shijiazhuang Kelin Electric Co., Ltd.
Co., Ltd., Shenzhen Kelu Electronic Technology Co., Ltd., Zhejiang Chentai Technology Co., Ltd., Guangdong Boli Technology Co., Ltd., cloud
China Southern Power Grid Co., Ltd., Shandong Provincial Institute of Metrology, Wasion Information Technology Co., Ltd., Wuhan Shengfan Electronics Co., Ltd.
Division, Huaihua Jiannan Electronic Technology Co., Ltd., Qingdao Qiancheng Technology Co., Ltd., State Grid Jibei Electric Power Co., Ltd. Electric Power Research Institute,
State Grid Jibei Electric Power Co., Ltd. Metering Center, Shanghai Belling Co., Ltd., State Grid Sichuan Electric Power Company Marketing Service Center, Zhongnanyi
Meter Co., Ltd., Zhejiang UBS Electronics Co., Ltd., Jiangyin Zhonghe Power Instrument Co., Ltd., Xi'an Xinlinda Digital Technology Co., Ltd.
The main drafters of this document. Wang Ronghua, Shao Fengyun, Zhou Xiaohua, Sun Yong, Ding Zhen, Zheng Mengxia, Jiang Weiping, Liu Xiancheng, Chen Zhiming, Ma Jun,
Wang Zhi, Wang Xiaojian, Zeng Shitu, Yang Huijun, Xu Chugong, Qu Jun, Jiang Bin, Wang Sanqiang, Liu Dan, Li Xin, Jiang Yu, Li Zhengfan, Li Rongping, Wang Qiang,
Ding Zhengguang, Liu Jianlei, Yan Yaofeng, Wang Xinjun, Shen Xin, Liu Yadong, Wang Wei, Wang Ting, Deng Shuyu, Yang Juexian, Gao Shuai, Ruan Yi, Lin Zichao, Jiang Yong,
Su Dongliang, Lei Ming, Zhang Zhijin.
The release status of previous versions of this document and the documents it replaces.
---First published as GB/T 22264.8-2009 in.2009;
--- This is the first revision.
Introduction
Installed digital display electrical measuring instruments are installed in various distribution cabinets and distribution boxes, and are widely used in industrial and mining enterprises, electric power, metallurgy, chemical industry,
In fields such as energy, medical care, and transportation, the application scenarios continue to expand. GB/T 22264 series standards have been promulgated and used for more than 10 years.
And market changes, the standard can no longer adapt to the development of technology and user needs.
GB/T 22264 aims to standardize the technology of installed digital display electrical measuring instruments by combining the latest product technology and user needs at home and abroad.
Specifications and safety requirements, and put forward corresponding test methods, to provide a product specification for manufacturers and users of such electrical measuring instruments,
It embodies most of the requirements of the technical specification for product ordering.
GB/T 22264 aims to standardize the technology of installed digital display electrical measuring instruments by combining the latest product technology and user needs at home and abroad.
Specifications and safety requirements, and put forward corresponding test methods, to provide a product specification for manufacturers and users of such electrical measuring instruments,
It embodies most of the requirements of the technical specification for product ordering.
GB/T 22264 is proposed to be composed of the following 8 parts.
--- Part 1.Definitions and general requirements. The purpose is to establish the definitions and
common enquiries.
--- Part 2.Special requirements for ammeters and voltmeters. The purpose is to develop special requirements for ammeters and voltmeters.
--- Part 3.Special requirements for power meters and reactive power meters. The purpose is to formulate special requirements for power meters and reactive power meters.
--- Part 4.Special requirements for frequency tables. The purpose is to develop special requirements for frequency tables.
--- Part 5.Special requirements for phase meters and power factor meters. The purpose is to formulate special requirements for phase meters and power factor meters.
--- Part 6.Special requirements for insulation resistance meters. The purpose is to formulate special requirements for insulation resistance meters.
--- Part 7.Special requirements for multi-function instruments. The purpose is to formulate special requirements for multi-function instruments.
--- Part 8.Test methods. The purpose is to standardize the test methods for installed digital display electrical measuring instruments.
In recent years, the international safety requirements for products have become more and more stringent. This revised standard, combined with IEC 61010-1.2010 and
GB/T 17215.211-2021 changed the safety-related content, clarified the terms of use, and improved product safety performance.
Installed digital display electrical measuring instrument
Part 8.Test methods
1 Scope
This document specifies the general test conditions, measuring equipment, samples, test procedures, and test data processing of installed digital display electrical measuring instruments.
Reasoning and test reports.
This document applies to newly manufactured power distribution systems below 750V DC and 690V AC with a nominal frequency of 50Hz or 60Hz.
Measuring ammeter and voltmeter, wattmeter and reactive power meter, frequency meter, phase meter and power factor meter, insulation resistance meter and any two
The multi-function instrument with combination of two or more types is also applicable to the digital display part of the electrical measuring instrument with analog/digital dual display.
Note 1.The above-mentioned "in the power distribution system below DC 750V" does not apply to the frequency meter, phase meter and power factor meter.
This document does not apply to.
--- Electric measuring instruments with direct acting analog indication only;
--- Portable digital display electrical measuring instrument;
--- There are other special-purpose instruments with national standards (or industry standards).
Note 2.This document does not specify the dimensional requirements of the instrument, see GB/T 1242-2000 for the dimensional requirements of the instrument.
2 Normative references
The contents of the following documents constitute the essential provisions of this document through normative references in the text. Among them, dated references
For documents, only the version corresponding to the date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to
this document.
GB/T 2423.1-2008 Environmental testing for electrical and electronic products - Part 2.Test methods Test A. Low temperature
GB/T 2423.2-2008 Environmental testing for electrical and electronic products - Part 2.Test methods Test B. High temperature
GB/T 2423.4-2008 Environmental testing for electrical and electronic products - Part 2.Test method Test Db. Alternating damp heat (12h
12h cycle)
GB/T 2423.5-2019 Environmental Testing Part 2.Test Methods Test Ea and Guidelines. Shock
GB/T 2423.10-2019 Environmental testing Part 2.Test method Test Fc. Vibration (sinusoidal)
GB/T 2423.37-2006 Environmental testing for electrical and electronic products - Part 2.Test methods Test L. Sand and dust test
GB/T 2423.38-2021 Environmental testing - Part 2.Test methods Test R. Water test methods and guidelines
GB/T 4208-2017 Enclosure protection level (IP code)
GB/T 5169.10-2017 Fire Hazard Tests for Electrical and Electronic Products - Part 10.Glow Wire/Hot Wire Basic Test Method Ignition
Hot wire apparatus and general test methods
GB/T 17215.9311-2017 Reliability of Electrical Measuring Equipment Part 311.Temperature and Humidity Accelerated Reliability Test
GB/T 17626.2 Electromagnetic Compatibility Test and Measurement Technology Electrostatic Discharge Immunity Test
GB/T 17626.3 Electromagnetic Compatibility Test and Measurement Technology Radio Frequency Electromagnetic Field Radiation Immunity Test
GB/T 17626.4 Electromagnetic Compatibility Test and Measurement Technology Electrical Fast Transient Burst Immunity Test
GB/T 17626.5 Electromagnetic Compatibility Test and Measurement Technology Surge (Shock) Immunity Test
GB/T 17626.6 Electromagnetic compatibility test and measurement technology Conducted disturbance immunity induced by radio frequency field
GB/T 17626.11 Electromagnetic Compatibility Test and Measurement Technology Voltage Dips, Short Interruptions and Immunity Tests to Voltage Changes
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 22264.8-2022_English be delivered?Answer: Upon your order, we will start to translate GB/T 22264.8-2022_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 7 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 22264.8-2022_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 22264.8-2022_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 22264.8-2022?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 22264.8-2022 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|