HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (25 Oct 2025)

GB/T 21739-2025 English PDF

GB/T 21739: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 21739-2025EnglishRFQ ASK 3 days [Need to translate] Safety rules for the construction and installation of home lifts Valid GB/T 21739-2025
GB/T 21739-2008English1389 Add to Cart 10 days [Need to translate] Rules for the construction and installation of home lifts Valid GB/T 21739-2008

Basic data

Standard ID GB/T 21739-2025 (GB/T21739-2025)
Description (Translated English) Safety rules for the construction and installation of home lifts
Sector / Industry National Standard (Recommended)
Date of Implementation 2026-03-01
Older Standard (superseded by this standard) GB/T 21739-2008

GB/T 21739-2008: Rules for the construction and installation of home lifts

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Rules for the construction and installation of home lifts ICS 91.140.90 Q78 National Standards of People's Republic of China Home elevator manufacturing and installation specifications Posted 2008-05-07 2008-11-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Introduction Ⅴ Introduction Ⅵ 1 Scope 1 2 Normative references 1 2 3 Terms 4 Basic Safety Requirements 3 4.1 General 3 3 4.2 Personal Protection Accessibility 3 4.3 Maintenance and inspection 4.4 Refractory 4 4.5 rated speed 4 4.6 4 stroke 4.7 rated load 4 4.8 Load Control 5 4.9 5 cab area 4.10 5 Number of passengers 4.11 Mechanical strength 5 4.12 prevent the device from external harmful effects Protection 5 Degree of protection for outdoor use 4.13 5 4.14 Minimum Channel 5 5 5 hoistway 5.1 General 5 Closed 5.2 hoistway 5 Top Space 5.3 7 5.4 pit space 8 5.5 car and counterweight/balancing weight lower space Personal Protection 9 5.6 hoistway wall 9 Strength 5.7 hoistway 10 5.8 Inspection doors and trap doors 10 Inlet 6 hoistway 10 6.1 General 10 6.2 layer gate width 10 6.3 Net height entrance gate layer 10 Layer gate structure 11 6.4 6.5 Locking and closed landing door 12 6.6 Emergency release 13 6.7 confirm the landing door closed electrical device 14 6.8 confirmed one more fan sliding door off the electrical device 14 Risk of trapped personnel working in the hoistway 6.9 14 14 7 Car 7.1 14 car entrance 7.2 net width and height of the car 15 7.3 effective area of \u200b\u200bthe car 15 7.4 Jiaoding 15 7.5 Car wall 15 7.6 Ventilation 16 7.7 floor surface 16 16 apron 7.8 7.9 dashboard 16 7.10 armrest 16 7.11 folding chair 16 Lighting 17 7.12 7.13 Safety car entrance 17 8 pairs of weight and balance weight 18 9 guide system 18 Car navigation system 18 9.1 9.2 pairs weight/counterweight guide system 18 9.3 Guidance stroke 18 9.4 rail 18 10 safety gear and overspeed governor 19 10.1 safety gear 19 10.2 governor 20 11 buffer 20 11.1 bottom buffer 20 11.2 top buffer 20 12 car and the face of the spacing between the shaft wall and the car entrance 21 between the member Faced with car entrance shaft wall between the car 21 12.1 Between 12.2 parts 21 13 drive system 21 13.1 General requirements 21 22 13.2 Braking System Emergency operation 23 13.3 13.4 rack and pinion drive additional requirements 23 13.5 drum and sprocket drive additional requirements 24 13.6 Additional requirements for wire rope traction drive 25 13.7 Screw and Nut Drivers Additional requirements 25 13.8 Additional requirements for hydraulic drive 27 14 electrical installation and electrical equipment and electrical control and electrical protection 33 14.1 General 33 14.2 Power 33 14.3 Master switch 33 14.4 electrical wiring and electrical installation 34 14.5 Lighting 35 14.6 socket 36 14.7 main contactor 36 14.8 AC power supply directly to motor 36 14.9 creepage distances, clearances and housing requirements 36 14.10 Electromagnetic Compatibility 37 14.11 37 Protection of electrical faults 14.12 Electrical safety devices 37 14.13 drive motor 39 and the operation of protection 14.14 Additional requirements for battery-powered 40 14.15 control unit 40 14.16 Emergency alarm device 42 14.17 Operation Control 43 15 test, inspection and recording 44 15.1 Type tests 44 44 15.2 Inspection 45 15.3 Record 16 usage information 45 16.1 General 45 16.2 Information and alarms 45 46 16.3 Operating Instructions 16.4 46 random file 16.5 mark 46 Fault Appendix A (normative) electrical components excluded 47 Appendix B (normative) use of periodic inspection and maintenance 51 Annex C (normative) Safety components Conformity type testing program 52 References 55

Foreword

The Standard Appendix A, Appendix B, Appendix C is a normative appendix. This standard by the National Standardization Technical Committee elevator (SAC/TC196) and focal points. This standard is drafted by. China Academy of Building Research Construction Mechanization Research Branch. Participated in the drafting of this standard. Schindler (China) Elevator Co., Otis Elevator (China) Investment Co., Ltd., Shanghai Mitsubishi Elevator Ltd., Hitachi Elevator (China) Co., Ltd., Suzhou Schindler Elevator Co., Ltd., West Otis Elevator Co., Ltd., Kone Elevator Co. The company, Shanghai Yongda Elevator Equipment Co., Ltd., Suzhou Jiangnan Jiajie Elevator Co., Ltd., ThyssenKrupp Elevator Home (Shanghai) Co., The company, Huasheng Fujitec Elevator Co., Ltd., Guangzhou Elevator Industry Co., Ltd., Shenyang Brilliant Elevator Co., Canny Elevator Shares Ltd., Suzhou southeast hydraulic lift Ltd., Shenyang Sanyo Elevator Co., Ltd. Xuchang West following the elevator. The main drafters of this standard. Chen Fengwang, B Bao-ming, Shen Yan, Hu Bin, Luguo Xiong, Wang Yongwang, gold afterlife, Ma Lingyun, Wang Weifeng, Weishan Hu, Xu Zhenghao, Chen Lu Yang, Zhou Xing, Li Cai, Wang Youlin, Ma Yiping Zhou Yin House, Wang Yongqiang, Li Jun.

Introduction

0.1 General 0.1.1 This standard from the standpoint of protecting personnel and equipment starting the development of home elevator manufacturing and installation specifications to reduce the use, maintenance or tight Emergency operations related hazards. 0.1.2 consider all the major mechanical hazards associated with home elevators, electrical hazards and by ignoring the principles of ergonomics risk arising Insurance, through risk assessment, to identify the major risk, specifies the requirements and measures to eliminate or reduce risks. Study in a home elevator The following aspects of the possibility of accidents. 0.1.2.1 could cause accidents due to the following. a) Cut. b) extrusion. c) fall. d) impact. e) trapped. f) an electric shock. g) material failure due to the following reasons. 1) mechanical damage; 2) wear and tear; 3) corrosion. 0.1.2.2 Protection Officer. a) use of personnel; b) the maintenance and inspection personnel; c) wells and machine rooms (if any) and the pulleys (if any) outside staff. 0.1.2.3 Protection of objects. a) in the car-mounted object; b) Household elevator components; c) Install a home elevator building. 0.2 standard not only specifies the basic safety requirements for home elevators, and provides home elevators installed in buildings (structures) in the most Low demand. 0.3 home elevators can be installed in new buildings and in buildings with. 0.4 home elevator manufacturer and the owner shall undertake consultations on the following issues. a) the intended use; b) environmental conditions; c) civil engineering problems; d) other aspects of the installation site; e) the suitability of the user. 0.5 In order to clarify the purpose of this standard and the avoidance of doubt in the implementation process, in the development of this standard, the following assumptions were made. 0.5.1 No special requirements parts meet the following requirements. a) in accordance with the usual engineering practice and calculation regulate the design, considering all failure modes; b) using a reliable mechanical and electrical construction; c) avoid the risk of hydraulic, pneumatic and other equipment produced in accordance with relevant common standards; d) known harmful materials (such as. asbestos) is not available for home elevators member; e) by a sufficient strength and good quality material. 0.5.2 in accordance with maintenance instructions, parts should be well maintained and maintain a normal working condition, despite the wear and tear, able to maintain the required characteristic. 0.5.3 The selection and configuration of the components in the expected environmental impacts and specific working conditions, should not affect the safety of the home elevator run. 0.5.4 bearing supports shall be designed to ensure that expected under a load of home elevators can operate safely. 0.5.5 The standard for electrical safety device requirements are. If the electrical safety devices in full compliance with the requirements of this standard, it may fail Regardless of sex. 0.5.6 When a person home elevators using a predetermined method, due to its own negligence and unintentional misuse caused issues should be protection. 0.5.7 In some cases, might make some kind of reckless action, this standard does not consider the simultaneous occurrence of two or more Lu Mang possibility of action and (or) violation of home elevators Instructions situation. 0.5.8 If during the maintenance period, a person is usually not easily accessible using the safety device is intentionally set to invalid, then the home elevator No guarantee safe operation, maintenance procedures you should follow to take additional measures to ensure the safety of personnel. The level of force used in 0.5.9. a) Static. 300N; Force b) the impact arising from. 1000N. This is the force of a person may be imposed. 0.5.10 In addition to the items listed below, a mechanical device in accordance with the requirements and standards of good examples manufactured, without being able to check the situation, the Will not cause damage to the extent of the danger. You should consider the following mechanical failure. a) suspension means breaking; b) the auxiliary ropes, chains and all connected with the break and relaxation; c) hydraulic system (not including tanks) fracture; d) hydraulic system (including cylinders) minor leaks; e) participation in one of the electromechanical brake drum brake disc brake mechanical parts or failure; f) on the hoisting rope traction wheel slip out of control; g) the failure of the main drive wheel traction unit and related components. 0.5.11 To ensure the safe operation of equipment operating ambient temperature range of use shall be considered home elevators the actual place, the device is running Ambient temperature range between + 5 ℃ ~ + 40 ℃. For hot or cold environments, additional requirements may be necessary. Home elevator manufacturing and installation specifications

1 Scope

1.1 standard provides home elevators manufacturing and installation should comply with the norms. Home elevators are for single-family use, and. a) layer between the fixed station, the car along the vertical inclination angle of 15 ° from the guide rails; b) the use of wheelchairs available for use or the personnel; c) (directly or indirectly), screw and nut supported or suspended by a rope, chain, rack and pinion, hydraulic cylinders; d) an independent hoistway. 1.2 This standard takes into account the main risk associated under the conditions foreseen by the manufacturer designed to use a home elevator. 1.3 This standard does not consider the additional requirements under the following conditions. a) used in harsh conditions (such as. extreme weather, strong magnetic fields); b) lightning protection; c) shall comply with the provisions of the special operation (eg. potentially explosive atmospheres); d) handling may cause hazardous conditions for the material; e) The main function is to transport the goods; f) vulnerable to vandalism; g) Dangerous generated during manufacture; h) earthquake, flood; i) fire protection, evacuation and running during the fire; j) noise and vibration; k) concrete, stone filler, wood, or other foundation or building design structures; l) embedded bolts of the support structure design; m) using GB/T 12995-2006 defined motorized wheelchair. 1.4 This standard does not apply elevators for public use.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 1243-2006 Short pitch transmission precision roller chains, bush chains, attachments and sprockets (ISO 606.2004, IDT) GB/T 3480-1997 involute cylindrical gear carrying capacity calculation methods (eqv ISO 6336-1 ~ 6336-3.1996) GB 4208-1993 housing protection (IP Code) (eqv IEC 529. 1989) GB/T 4723 printed circuits copper clad phenolic paper laminate (GB/T 4723-1992, neqIEC 249-2. 1985 ~ 1988) GB/T 4724 printed circuits copper clad epoxy laminate paper (GB/T 4724-1992, neqIEC 249-2. 1987) GB/T 4728 (all parts), Graphical symbols for electrical diagrams GB 4943-2001 Safety of information technology equipment (idt IEC 60950.1999) GB 5226.1-2002 Safety of machinery electrical equipment Part 1. General requirements (IEC 60204-1.2000, IDT) GB 5226.2-2002 Safety of machinery electrical equipment Part 32. Requirements for hoisting machines (IEC 60204-32. 1998, IDT)