US$299.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 21529-2008: Determination of water vapour transmission rate for plastic film and sheeting -- Electrolytic detection sensor method Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 21529-2008 | English | 299 |
Add to Cart
|
3 days [Need to translate]
|
Determination of water vapour transmission rate for plastic film and sheeting -- Electrolytic detection sensor method
| Valid |
GB/T 21529-2008
|
PDF similar to GB/T 21529-2008
Basic data | Standard ID | GB/T 21529-2008 (GB/T21529-2008) | | Description (Translated English) | Determination of water vapour transmission rate for plastic film and sheeting -- Electrolytic detection sensor method | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | A80 | | Classification of International Standard | 55.020 | | Word Count Estimation | 13,133 | | Date of Issue | 2008-04-01 | | Date of Implementation | 2008-10-01 | | Quoted Standard | GB/T 1037-1988; GB/T 6672 | | Adopted Standard | ISO 15106-3-2003, MOD | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 5, 2008 (No. 118 overall) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the use of electrolytic sensor to measure water vapor permeability test methods. This standard applies to rapid determination of plastic film, sheet and plastic multi-layer structure containing water vapor permeability of materials. |
GB/T 21529-2008: Determination of water vapour transmission rate for plastic film and sheeting -- Electrolytic detection sensor method ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Determination of water vapour transmission rate for plastic film and sheeting. Electrolytic detection sensor method
ICS 55.020
A80
National Standards of People's Republic of China
Plastic film and sheet water vapor
Transmittance measurement of electrolytic sensor method
(ISO 15106-3.2003, Plastics-Filmandsheeting-Determination
Part 3. Electrolyticdetectionsensormethod, MOD)
Posted 2008-04-01
2008-10-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
This revised standard adopts ISO 15106-3.2003 "Plastics film and sheet water vapor permeability test methods - Part 3. Electrolytic
Sensor Detection "(in English).
This standard is based on ISO 15106-3.2003 redrafted. The list of standard and ISO 15106- reg number in Appendix D
3.2003 reg control list numbered.
Taking into account China's national conditions, in the use of ISO 15106-3.2003, the standard of this made some changes. About the technical differences have been incorporated into positive
The paper identifies a single vertical line and it deals with the provisions margin. These technical differences are given in Appendix E and its prime
Because the list for reference.
This standard and ISO 15106-3.2003 standard compared, the main differences are as follows.
--- 7.2.4 ~ 7.2.7 adds provisions were porous plate, temperature control device, the electrolytic cell, valve components made several instructions;
--- Increased 7.3 standard film to calibrate the device provides that in order to make the standard test data and other standard test methods
Data comparable;
--- In the test step 9.7, the provisions of the current reaches a constant value, that water vapor reaches a steady state determination condition;
--- In Chapter 11, the test results, it is prescribed deviation value for each test sample and the arithmetic mean of the sample;
--- Remove the ISO 15106-3.2003 Chapter 12;
--- Added Appendix B. Appendix B using ASTME104.2002 "to maintain a constant relative humidity using an aqueous solution of a standard method"
And DIN53122.2. test 1982 "Testing of plastic films, rubber, paper, cardboard and other sheet water vapor permeability
Data relative humidity of saturated aqueous solution of different salts given electrolysis method "provided that can be achieved;
--- Added Appendix C. Appendix C reference DIN 53122.2. 1982 the instrument constant (8.067) derivation process, the instrument often
Number was derived.
This standard Annex A, Annex B is normative appendix, Appendix C, Appendix D, Appendix E is informative appendix.
This standard by the National Packaging Standardization Technical Committee and centralized.
This standard was drafted. China Packaging Research & Test Center, the National Packaging Products Quality Supervision and Inspection Center (Jinan), Labthink
Technology Co., Ltd.
The main drafters of this standard. Wang Xingdong, plus Zhou Yan, Niu Shumei, Han snow-capped mountains, from the forest, Zhao Jiang, Zhang Mu Qing, Jiang Yun in.
Plastic film and sheet water vapor
Transmittance measurement of electrolytic sensor method
1 Scope
This standard specifies the test methods for electrolytic sensors measuring water vapor transmission rate.
This standard applies to rapid determination of plastic film, sheet and the multilayer structure containing water vapor transmission rate of plastic material.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 1037-1988 plastic film and sheet water vapor permeability test methods Cup method
GB/T 6672 plastic film and sheet thickness measurement of the mechanical measurements (GB/T 6672-2001, idt ISO 4593.1993)
3 Terms and Definitions
The following terms and definitions apply to this standard.
3.1
Under certain conditions, the amount of water vapor per unit time through unit area of \u200b\u200ba sample.
NOTE. The standard transmission rate of water vapor in the definition of GB/T 1037-1988 water vapor transmission rate of the definition of the meaning is the same, the water vapor transmission rate (amount)
Units of grams per square meter per 24 hours [g/(m2 · 24h)].
Principle 4
The sample was clamped to the permeate chamber, the sample chamber will penetrate into dry chamber and the wet chamber (humidity adjustable). With dry carrier gas flow in the dry chamber
Through, from the wet steam chamber through the sample is carried by the carrier gas to the electrolytic cell. The cell structure is generally. There are two spiral metal electrodes within
Electrode, the electrode is mounted on the inner wall of a glass capillary, the electrode surface is coated with a thin layer of phosphorus pentoxide. The carrier gas through a glass capillary, the carrier gas
The vapor is carried pentoxide quantitatively absorbed. By applying to the electrodes a certain DC voltage electrolysis into hydrogen and water vapor
oxygen. According to the electrolytic current value to calculate the amount of water vapor per unit time through unit area of \u200b\u200bspecimen.
5 Sample
5.1 sample should be representative, uniform thickness, no creases, folds, pinholes. Area of \u200b\u200bsample should be greater than the osmotic chamber through the area, the sample should be secret
Package good clip.
5.2 water vapor transmission rate of at least three test specimens.
5.3 thickness shall be measured in accordance with the provisions of GB/T 6672, each sample measuring at least three equally spaced points.
6 for conditioning
At a temperature of 23 ℃ ± 2 ℃, relative humidity of 50% ± 10% of the sample under the conditions of state regulation, settling time at least 4h.
|