US$274.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 21210-2016: Starting performance of single-speed three-phase cage induction motors Status: Valid GB/T 21210: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 21210-2016 | English | 274 |
Add to Cart
|
3 days [Need to translate]
|
Starting performance of single-speed three-phase cage induction motors
| Valid |
GB/T 21210-2016
|
| GB/T 21210-2007 | English | 439 |
Add to Cart
|
3 days [Need to translate]
|
Starting performance of single-speed three-phase cage induction motors
| Obsolete |
GB/T 21210-2007
|
PDF similar to GB/T 21210-2016
Basic data | Standard ID | GB/T 21210-2016 (GB/T21210-2016) | | Description (Translated English) | Starting performance of single-speed three-phase cage induction motors | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | K20 | | Classification of International Standard | 29.160.01 | | Word Count Estimation | 14,177 | | Date of Issue | 2007-12-03 | | Date of Implementation | 2017-03-01 | | Older Standard (superseded by this standard) | GB/T 21210-2007 | | Regulation (derived from) | National Standard Announcement 2016 No.14 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |
GB/T 21210-2016: Starting performance of single-speed three-phase cage induction motors---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Starting performance of single-speed three-phase cage induction motors
ICS 29.160.01
K20
National Standards of People's Republic of China
Replace GB/T 21210-2007
Starting performance of single speed three - phase cage induction motor
(IEC 60034-12..2016, IDT)
2016-08-29 released
2017-03-01 implementation
General Administration of Quality Supervision, Inspection and Quarantine of the People 's Republic of China
China National Standardization Management Committee released
Directory
Preface I
1 Scope 1
2 normative reference document 1
3 Terms and definitions 1
4 symbol 2
5 design code 3
Requirements for design requirements
7 NE start-up requirements 4
8 NY design and NEY design starting requirements 4
9 H design requirements 4
10 Start requirements for HE design 5
11 HY design and HEY design of the starting requirements 5
Reference 11
Foreword
This standard is drafted in accordance with the rules given in GB/T 1.1-2009.
This standard replaces GB/T 21210-2007 "single-speed three-phase cage induction motor starting performance", and GB/T 21210-2007 phase
In addition to editorial changes, the main changes are as follows.
- Added terms and definitions of rated voltage and stall current (see 3.6, 3.8);
- four design parameters in accordance with IEC 60034-30-1 energy efficiency rating motors, indicated by the letter E (see Chapter 5);
--- Motor power output range from 0.4kW ~ 1600kW extended to 0.12kW ~ 1600kW, increase the corresponding eigenvalue (see
Table 1 to Table 7);
- a new division and definition of the motor power output range and its power ratings (see Table 2, Table 3);
- Increased the formula for calculating the stall current by blocking the apparent power (see 6.2);
--- cancel the original standard table 6, by the reference document (see 6.2).
This standard uses the translation method equivalent to IEC 60034-12..2016 "single speed three phase cage induction motor starting performance".
And the normative reference in this standard international documents are consistent with the relationship between China's documents are as follows.
Rotating motor quota and performance (IEC 60034-1..2004, IDT);
- GB 3836.1-2010 Explosive atmospheres - Part 1. General requirements for equipment (IEC 60079-0..2007, MOD)
--- GB 3836.3-2010 Explosive atmospheres Part 3. Equipment protected by increased safety "e" (IEC 60079-7..2006,
IDT).
This standard is proposed by China Electrical Equipment Industry Association.
This standard is under the jurisdiction of the National Committee for Standardization of Rotating Electric (SAC/TC26).
This standard is responsible for the drafting unit. Shanghai Electric System Energy Saving Engineering Technology Research Center Co., Ltd., Jiangsu Xanda Explosion-proof Co., Ltd.
Division, Nanjing Zhuzhou Motor Co., Ltd., Xi'an Pacific Cable Motor Co., Ltd., Wuxi Ou Rui Jing Electrical Co., Ltd., Shandong Huali Motor Group
Co., Ltd., Jiangsu Dazhong Electric Co., Ltd., Zhejiang Jinlong Electric Co., Ltd., Weihai Taifu Sima Electric Co., Ltd.,
Jiangsu Universal Special Motor Co., Ltd., Boshan special type Motor Co., Ltd., Shanghai Tak drive Electric Co., Ltd., Zhejiang Hulong Technology shares
Limited company, Lu'an City micro motor limited liability company, Xiangtan Electric Co., Ltd.
This standard participates in the drafting unit. Shanghai ABB Motor Co., Ltd., Hebei Electric Co., Ltd., Anhui Wannan Electric Co., Ltd.
Division, Wolong Electric Group Co., Ltd., the state bridge gantry crane product quality supervision and inspection center, Shanghai Light Land Motor Co., Ltd.,
Zhejiang Zhonglong Electric Co., Ltd., Ningbo Dongli Co., Ltd.
The main drafters of this standard. Gu Weidong, Lu Jinsheng, Zhou Limin, Liu Fuxiang, Fei Mingyu, Zhang Wenbin, Wang Hafen, Ye Ye,
Fang Yulan, Zhang Jie, Chen Xiangen, Zhu Yecheng, Duan Zhicheng, Li Suping.
This standard replaced the previous version of the standard release.
--- GB/T 21210-2007.
Starting performance of single speed three - phase cage induction motor
1 Scope
This standard specifies the design parameters of the 50Hz or 60Hz single speed three-phase cage induction motor starting performance. The motor should be in line
IEC 60034-1 standard, and
● rated voltage does not exceed 1000V;
● direct start or star - triangular start;
● based on S1 work system;
● can have any kind of protection and explosion-proof grade.
This standard is also applicable to dual voltage motors with the same magnetic saturation at both voltages.
The torque value, apparent power and current values given by this standard are limits (minimum or maximum, no tolerance).
Note 1. This standard does not require the manufacturer to produce all of the eight designs of the motor. According to this standard, any design will be negotiated by the manufacturer and the user.
Note 2. Special purpose motors may not be in accordance with the above eight design requirements.
Note 3. It should be noted that the values given by the manufacturer on the sample may include tolerances and the tolerances shall comply with the provisions of IEC 60034-1.
Note 4. The rotors listed in the table are equivalent to the steady-state current of the symmetrical power corresponding to the rotor stall. There will be one when the motor is connected to the current
0.5 weeks of asymmetric instantaneous peak current, the steady-state value of 1.8 times to 2.8 times. The peak current and decay time of this current is related to the design and closing of the motor
Phase angle is a function of the relationship.
2 normative reference documents
The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article
Pieces. For undated references, the latest edition (including all modifications) applies to this document.
IEC 60034-1 Rotating electrical machines - Part 1. Definitions and performance (Rotatingelectricalmachines-Part 1. Ratingand
performance
IEC 60034-30-1 Rotating electrical machines - Part 30-1. On-line operation of AC motor efficiency classification (IE code) [Rotating
electricalmachines-Part 30-1. Efficiencyclassesofline-operatedA.C.motors (IE-code)]
IEC 60079-7 Electrical apparatus for explosive gas atmospheres - Part 7. Increased safety type "Exeb" (Electrical finger)
explosivegasatmospheres-Part 7. Increasedsafety'Exeb ')
3 terms and definitions
The following terms and definitions apply to this document.
3.1
Rated torque ratedtorque
TN
Torque of the motor at rated output and rated speed.
[GB/T 2900.25-2008, definition 3.17]
3.2
Lock-rotortorque
Tl
The minimum measured value of the torque produced by the motor at the rated frequency, the rated voltage and the rotor when it is blocked at all its angular positions.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 21210-2016_English be delivered?Answer: Upon your order, we will start to translate GB/T 21210-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 21210-2016_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 21210-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 21210-2016?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 21210-2016 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|