US$709.00 · In stock Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 20994-2007: Shunt capacitors and AC filter capacitors for HVDC transmission systems Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 20994-2007 | English | 709 |
Add to Cart
|
5 days [Need to translate]
|
Shunt capacitors and AC filter capacitors for HVDC transmission systems
| Valid |
GB/T 20994-2007
|
PDF similar to GB/T 20994-2007
Basic data | Standard ID | GB/T 20994-2007 (GB/T20994-2007) | | Description (Translated English) | Shunt capacitors and AC filter capacitors for HVDC transmission systems | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | K42 | | Classification of International Standard | 31.060.70 | | Word Count Estimation | 27,297 | | Date of Issue | 2007-06-21 | | Date of Implementation | 2008-02-01 | | Regulation (derived from) | National Standard Announcement 2007 No.6 (Total No.106) (National-Standard-Commission) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard applies to the installation in the HVDC converter station exchange volumes, used to provide reactive power compensation of shunt capacitors and shunt capacitor banks and used to filter the AC side harmonics and provide reactive power compensation at the fundamental frequency of 50Hz or 60Hz AC filter capacitor and the AC filter capacitor bank. |
GB/T 20994-2007: Shunt capacitors and AC filter capacitors for HVDC transmission systems---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Shunt capacitors and AC filter capacitors for HVDC transmission systems
ICS 31.060.70
K42
National Standards of People's Republic of China
HVDC systems with parallel capacitor
And the AC filter capacitor
Posted 2007-06-21
2008-02-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
Introduction Ⅱ
1 General 1
2 Quality requirements and testing 6
3 Design and structural requirements 12
4 insulation level 14
5 Overload 16
6 Safety requirements 16
Flag capacitor unit 7 17
Flag capacitor banks 8 17
9 for installation and operation are 18
Appendix A (informative) HVDC transmission line common AC filter wiring diagram Example 20
Calculate capacitor discharge resistor and discharge time of Annex B (informative) Equation 22
Foreword
The Standard Appendix A and Appendix B are informative.
The standard proposed by China Electrical Equipment Industrial Association.
This standard by the National Standardization Technical Committee on Power capacitor (SAC/TC45) centralized.
This standard drafting of the main unit. Electric Power Research Institute in Xi'an capacitors, Electrical Machinery Industry Beijing Technology and Economy Institute.
Participated in the drafting of this standard. Xi'an Electric Power Capacitor Co., Ltd., ABB Xi'an Power Capacitor Co., Ltd, China Power
Force Research Institute, Xi'an High Voltage Apparatus Research Institute.
The main drafters of this standard. Liu Jing, Guo Tianxing, room sworn, Jia Hua, Wang Kun, Ren Qiang, Li Huaiyu, in Kunshan, Zhang Wanrong, Mushu Yun, Zhu Ting,
Zhou Denghong.
This standard is the first release.
Introduction
HVDC in China's power grid construction, power transmission for long distance and large-area networking has a very broad prospects for development, as is currently the
In order to solve the high-voltage, large-capacity, long-distance power transmission and important means of asynchronous networking. According to China's direct DC transmission engineering requirements and high pressure
Project stream transmission technology trends undertaken in the digestion and absorption of imported technology, the domestic HVDC project construction experience and independent research equipment
Based on the research to develop national standards for HVDC transmission system equipment. Including basic standards, equipment standards and master control and protection equipment
standard. Projects have been completed or are ongoing to develop a total of 19 national standards.
(1) "performance of the first part of the steady-state performance HVDC system"
(2) "Performance of HVDC systems failures second part of the operation."
(3) "The third part of the performance of HVDC system dynamic performance."
(4) "HVDC converter station insulation coordination procedures"
(5) "HVDC converter station losses OK"
(6) "Transformers for the second part of HVDC converter transformers"
(7) "with oil - immersed HVDC converter transformer technical parameters and requirements"
(8) "HVDC oil - immersed smoothing reactors"
(9) "HVDC oil - immersed smoothing reactors and technical requirements."
(10) "HVDC converter station gapless metal oxide surge arresters Guidelines"
(11) "HVDC systems with parallel capacitors and the AC filter capacitor"
(12) "HVDC systems with DC smoothing capacitor"
(13) "General requirements for HVDC thyristor with ordinary"
(14) "transmission and distribution systems power electronics static var compensator device thyristor valve test"
(15) "HVDC system control and protection equipment"
(16) "HVDC converter station noise"
(17) "HVDC bushing technical performance and test methods"
(18) "General requirements for HVDC light control thyristor"
(19) "DC system complete sets of equipment research and Guidelines"
HVDC systems with parallel capacitor
And the AC filter capacitor
1 General
1.1 Scope and purpose
This standard is suitable for installation in HVDC converter stations AC side, for providing reactive power compensation of shunt capacitors and shunt capacitor
Groups and used to filter out AC side harmonics and provide reactive power compensation at the fundamental frequency of 50Hz or 60Hz AC filter capacitor and filter exchange
Wave capacitor bank.
The purpose of this standard are.
a) set forth uniform rules regarding performance, testing and rating of;
b) set forth the specific safety rules;
c) provide guidelines for installation and operation.
1.2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard. However, according to research encourages the parties to the agreement
Study whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 11024.1 rated voltage above 1kV shunt capacitors for ac power systems - Part 1. General - Performance, testing and
Safety requirements for fixed installation and operation guidelines (GB/T 11024.1-2001, IEC 60871-1.1997, MOD)
GB/T 11024.2 rated voltage above 1kV shunt capacitors for ac power systems - Part 2. Endurance testing
(GB/T 11024.2-2001, idt IEC 60871-2.1999)
GB/T 11024.4 rated voltage above 1kV shunt capacitors for ac power systems - Part 4. Internal fuses
(GB/T 11024.4-2001, idt IEC 60871-4.1996)
GB/T 13540 high-voltage switchgear earthquake resistance performance test
GB/T 16927.1 High-voltage test techniques Part 1. General test requirements (GB/T 16927.1-1997, eqv IEC
60060-1. 1989)
1.3 Terms and Definitions
This standard uses the following terms and definitions.
1.3.1
It is a dielectric and spaced electrodes composed of members.
1.3.2
By one or more capacitor elements assembled in a single housing and a lead terminal of the assembly.
1.3.3
All units are connected in parallel with a capacitor.
1.3.4
And by the support frame is mounted on one or more series segments, insulators, cable capacitor constituted assembly.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 20994-2007_English be delivered?Answer: Upon your order, we will start to translate GB/T 20994-2007_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 20994-2007_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 20994-2007_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|