|
US$674.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 20819.1-2015: Controllers with analogue signals for use in industrial-process control system -- Part 1: Methods of evaluating the performance Status: Valid GB/T 20819.1: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 20819.1-2015 | English | 674 |
Add to Cart
|
4 days [Need to translate]
|
Controllers with analogue signals for use in industrial-process control system -- Part 1: Methods of evaluating the performance
| Valid |
GB/T 20819.1-2015
|
| GB/T 20819.1-2007 | English | RFQ |
ASK
|
6 days [Need to translate]
|
Industrial process control system with analog signal controllers -- Part 1: Methods for performance evaluation
| Obsolete |
GB/T 20819.1-2007
|
PDF similar to GB/T 20819.1-2015
Basic data | Standard ID | GB/T 20819.1-2015 (GB/T20819.1-2015) | | Description (Translated English) | Controllers with analogue signals for use in industrial-process control system -- Part 1: Methods of evaluating the performance | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | N18 | | Classification of International Standard | 25.040 | | Word Count Estimation | 34,356 | | Date of Issue | 2015-02-04 | | Date of Implementation | 2015-08-01 | | Older Standard (superseded by this standard) | GB/T 20819.1-2007 | | Quoted Standard | IEC 60068-2-6; IEC 60068-2-30; IEC 60068-2-31; IEC 61000-4-2; IEC 61000-4-3; IEC 61010-1; IEC 61298-1; IEC 61298-3; IEC 61298-4 | | Adopted Standard | IEC 60546-1-2010, IDT | | Regulation (derived from) | National Standards Bulletin 2015 No. 3 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This Standard is applicable to a continuous analog consistent with current national standard input and output signals pneumatic and electric industrial process PID regulator. It should be noted, the test prescribed in this section cover the test with the corresponding signal applied to the same principle but are different signal conditioner continuous signal. Also note that this section applies only analog components of electric or pneumatic industrial process regulator of regulators with a microprocessor can be implemented by reference. This section is intended to have a harmonized test methods analog input and output industrial process PID controller signal performance evaluation requirements. |
GB/T 20819.1-2015: Controllers with analogue signals for use in industrial-process control system -- Part 1: Methods of evaluating the performance ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Controllers with analogue signals for use industrial-process control system Part 1. Methods of evaluating the performance
ICS 25.040
N18
National Standards of People's Republic of China
Replacing GB/T 20819.1-2007
Industrial process control systems using analog signal conditioner
Part 1. Methods of evaluating performance
Part 1. Methodsofevaluatingtheperformance
(IEC 60546-1.2010, IDT)
Issued on. 2015-02-04
2015-08-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Introduction Ⅲ
1 Scope 1
2 Normative references 1
3 Terms and definitions 2
4 3 basic relationship
4.1 ideal regulator input-output relationship 3
4.2 Limit 4
Dial scale value adjuster 4.3 5
5 5 General test conditions
5.1 Environmental conditions 5
5.2 Conditions for source 6
5.3 load impedance 6
5.4 Other conditions 6
5.5 stable regulator output 6
6 static error 8
6.1 Test Setup 8
6.2 Initial conditions 8
6.3 Test procedure 8
7 dial markings and scale value 8
7.1 calibration set value scale value 8
7.2 Proportional action 9
7.3 Integral action 12
7.4 Derivative action 12
8 in the amount of influence 14
8.1 Overview 14
14 8.2 Initial conditions
8.3 Climate Impact 15
8.4 Mechanical impact 15
8.5 for sources on 16
17 8.6 Electrical interference
8.7 output load (only for electric actuator) 20
8.8 20 accelerated life test work
9 output characteristics and energy consumption 21
21 9.1 Energy Consumption
9.2 "Auto"/"Manual" Switch 21
9.3 electrical output ripple content 22
10 Frequency response 22
22 10.1 Application of frequency response test
Test procedure 22 10.2
23 10.3 Analysis of test results
11 23 Other tests
11.1 23 Withstand voltage test
11.2 Insulation resistance 24
11.3 Input over range 24
12 Literature 24
Technical inspection 13 24
14 25 Test Report
15 Test List 25
References 28
Foreword
GB/T 20819 "industrial process control systems using analog signal conditioner" is divided into two parts.
--- Part 1. Methods for performance evaluation;
--- Part 2. Inspection and routine testing.
This is Part 1 GB/T 20819 of.
This section drafted in accordance with the rules of GB/T 1.1-2009 and GB/T 20000.2-2009 given.
This Part replaces GB/T 20819.1-2007 "industrial process control systems using analog signal controllers - Part 1. Performance Evaluation party
Law ", this part of technological change and GB/T 20819.1-2007 compared as follows.
--- Clear of this section applies to electric and pneumatic industrial process PID controller (see Chapter 1, Chapter 1 of the 2007 edition);
--- Increase and update the normative references;
--- Increase the "dead zone, the average error of the stroke, lower stroke average error average error, hysteresis" and other terms and definitions, and simplified positive
The content of the text (see 3.9 to 3.13, and 71, 2007, edition of Chapter 4 and 7.1.);
Environmental conditions --- General test conditions clearly defined by the IEC 61298-1 requirements (see 51, 2007 version 5.1.);
--- Arbitration measurement standard reference atmospheric conditions than the increase in "To tropical, subtropical, and other specific requirements, can be used for
Generation of the reference atmospheric pressure. "(See 513, 2007 edition of 5.1.3.);
--- Clear the load impedance conditions for testing in accordance with IEC 61298-1 requirements (see 53, 2007 version 5.3.);
--- Clear the setpoint value scale specific validation check is 0%, 20%, 40%, 60%, 80% and 100% (see 7.1, 2007
Version 7.1);
--- Environmental temperature test, the test based on changes to IEC 61298-3, an increase of simplified test content (that is, "During the test,
If the multi-party consent, the test is only the instrument 20 ℃ (reference value), the maximum specified in the instrument, and the instrument specified minimum
This 4 at 20 ℃ temperature is sufficient. "), While increasing the rate of change in the ambient temperature requirements (less than 1 ℃/min) (see
.. 831, the 2007 version 8.2.1);
--- Relative humidity test, the test based on changes to IEC 61298-3 (see 832, 2007 edition of 8.2.2.);
--- Increased electrostatic discharge test item (see 8.6.6 and Chapter 15);
--- Test reporting requirements increases the reference document (see Chapter 14).
This section uses the translation method is equivalent to using IEC 60546-1.2010 "industrial process control systems using analog signal conditioner Part 1.
Performance evaluation method "(in English).
Consistency correspondence between this part of international documents and normative references of our files are as follows.
--- GB/T 2423.4-2008 Environmental testing for electric and electronic products Part 2. Test methods - Test Db alternating hot and humid
(12h 12h cycle) (IEC 60068-2-30.2005, IDT);
--- GB/T 2423.7-1995 Environmental testing for electric and electronic products Part 2. Test methods Test Ec and guidance. Drop
And topple (Primarily for equipment - type specimens) (idt IEC 60068-2-31. 1982);
--- GB/T 2423.10-2008 Environmental testing for electric and electronic products Part 2. Test methods Test Fc. Vibration (sinusoidal)
(IEC 60068-2-6.1995, IDT);
--- GB/T 2900.56-2008 Electrotechnical terminology automatic control (IEC 60050-351.2006, IDT);
--- GB 4793.1-2007 measurement, control and laboratory use safety requirements for electrical equipment - Part 1. General requirements
(IEC 61010-1.2001, IDT);
--- GB/T 17626.2-2006 Electromagnetic compatibility - Testing and measurement techniques - Electrostatic discharge immunity test (IEC 61000-4-2.
2001, IDT);
--- GB/T 17626.3-2006 Electromagnetic compatibility - Testing and measurement techniques RFEMS test
(IEC 61000-4-3.2002, IDT);
--- GB/T 18271.1-2000 Process measurement and control devices - General methods and procedures for evaluating performance - Part 1. General
(Idt IEC 61298-1.1995);
--- GB/T 18271.3-2000 Process measurement and control devices - General methods and procedures for evaluating performance - Part 3. Impact amount
Impact test (idt IEC 61298-3.1998);
--- GB/T 18271.4-2000 Process measurement and control devices - General methods and procedures for evaluating performance - Part 4. Evaluation of newspaper
Report content (idt IEC 61298-4.1995).
This part made the following editorial changes.
a) Remove the IEC 60546-1.2010 foreword and preface;
b) Where "IEC 60546" where to "GB/T 20819";
c) on the part of the symbol in accordance with Chinese conversion.
This part is proposed by China Machinery Industry Federation.
This part of the measurement and control of Standardization Technical Committee (SAC/TC124) is administered by the National industrial processes.
This section is drafted. Xiamen-Automation Technology Co., Ltd., Hangzhou Pangu Automation System Co., Ltd., Beijing Jin Shi meter
Ltd., Southwest University, Shenzhen standard Li Technology Development Co., Beijing peacekeeping Shing New Instrument Technology Co., Ltd., Fuzhou from Baxter
Automation Equipment Co., Ltd., Shanghai Automation Instrumentation Co., Ltd., Anhui Blue Run Automation Instrumentation Co., Ltd., Chongqing Electric Power Technical College
Schools, open Kaifeng Instrument Automation Instrumentation Co., Nanjing gifted times Electric Co., Ltd., Fujian Shunchang Rainbow Run Precision Instrument Co., Ltd., Xiamen security
East Electronics Co., Ltd., Zhongshan City, East Kawasaki Electric Co., Ltd., Henan Hanwei Electronics Co., Ltd., Fujian on the Run Precision Instrument Co.,
Xi'an University of Posts.
The main drafters of this section. Zhou Yu, Wang Qi, Guo hero, Zhihua, Gong Xiaodong, Zhang Yu, YT, ARCHIVES, Zhou Hongming, Ni Min,
Chen Wanlin, Zhang Bo, Wang Jiacheng, Dong Jian, Chen Zhiyang, Xiao country specifically, Zhousong Ming, Zhang Guang, Ge Jian, Li Caiqin, Zhao Fulan, Xie Zhen, Yang Songhua.
This part of the standard replaces the previous editions are.
--- GB 4730-1984;
--- GB/T 20819.1-2007.
Industrial process control systems using analog signal conditioner
Part 1. Methods of evaluating performance
1 Scope
GB/T 20819 in this section applies to electrical and pneumatic PID with continuous analog input and output signals consistent with existing national standards for
Fixed industrial process controller.
It should be noted, the test specified in this part covered with the corresponding test signal applied to the same principle but with different signals are continuous channel
No. regulator. It should also be noted that the partially electric or pneumatic industrial process applies only analog components regulator, on with the microprocessor
Regulators may refer to.
This section is intended to assess the performance of an analog input and output signals 1) industrial process PID regulator harmonized test methods specified.
While other manufacturers agreed conditions and the user does not exist, the test conditions specified in this part, such as ambient temperature, power supply range and so on.
When in this section do not need to conduct a comprehensive assessment, it can press the relevant section of this part of the test required, and report test results.
Manufacturers and users should be based on the characteristics and use of the equipment, the test procedures to reach consensus.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
IEC 60068-2-6 Environmental testing - Part 2-6. Test methods - Test Fc. Vibration (sinusoidal) [Environmentaltesting-
Part 2-6. Tests-TestFc. Vibration (sinusoidal)]
IEC 60068-2-30 Environmental testing - Part 2-30. Test methods - Test Db alternating hot and humid (12h 12h cycle) [Envi-
ronmentaltesting-Part 2-30. Tests-TestDb. Dampheat, cyclic (12h 12hcycle)]
IEC 60068-2-31 Environmental testing - Part 2-31. Test methods - Test Ec. Drop and topple (Primarily for equipment - type sample
Products) (Environmentaltesting-Part 2-31. Tests-TestEc. Roughhandlingshocks, primarilyforequip-
ment-typespecimens)
IEC 61000-4-2 Electromagnetic compatibility (EMC) Part 4-2. Testing and measurement techniques - Electrostatic discharge immunity test [Elec-
tromag-neticcompatibility (EMC) -Part 4-2. Testingandmeasurementtechniques-Electrostaticdis-
chargeimmunitytest]
IEC 61000-4-3 Electromagnetic compatibility (EMC) Part 4-3. Testing and measurement techniques RFEMS test
[Electromagneticcompatibility (EMC) -Part 4-3. Testingandmeasurementtechniques-Radiated,
radio-frequency, electromagneticfieldimmunitytest]
IEC 61010-1 measurement, control and laboratory use Part 1 Safety requirements for electrical equipment. General requirements (Safetyrequire-
mentsforelectricalequipmentformeasurement, control, andlaboratoryuse-Part 1. Generalrequire-
ments)
IEC 61298-1 Process measurement and control devices - General methods and procedures for evaluating performance - Part 1. General (Processmeas-
urementandcontroldevices-Generalmethodsandproceduresforevaluatingperformance-Part 1.
Generalconsiderations)
1) See GB/T 3369.1 and GB/T 3369.2.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 20819.1-2015_English be delivered?Answer: Upon your order, we will start to translate GB/T 20819.1-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 20819.1-2015_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 20819.1-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 20819.1-2015?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 20819.1-2015 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|