US$519.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 20441.6-2017: Electroacoustics -- Measurement microphones -- Part 6: Electrostatic actuators for determination of frequency response Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 20441.6-2017 | English | 519 |
Add to Cart
|
4 days [Need to translate]
|
Electroacoustics -- Measurement microphones -- Part 6: Electrostatic actuators for determination of frequency response
| Valid |
GB/T 20441.6-2017
|
PDF similar to GB/T 20441.6-2017
Basic data | Standard ID | GB/T 20441.6-2017 (GB/T20441.6-2017) | | Description (Translated English) | Electroacoustics -- Measurement microphones -- Part 6: Electrostatic actuators for determination of frequency response | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | A59 | | Classification of International Standard | 17.140.50 | | Word Count Estimation | 26,268 | | Date of Issue | 2017-11-01 | | Date of Implementation | 2018-05-01 | | Quoted Standard | IEC 61094-1; IEC 61094-2; IEC 61094-3; IEC 61094-5; ISO/IEC GUIDE EXPRESS-1995 | | Adopted Standard | IEC 61094-6-2004, IDT | | Regulation (derived from) | National Standard Announcement 2017 No. 29 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies: 1. Electrostatic exciter for the design of conductive diaphragm microphones; 2. Confirmation of electrostatic exciter; 3. Determining the response of the microphone electrostatic exciter. This section applies to the electrostatic actuator applications, including the following: 1. Detection of microphone frequency response changes in technology; 2. Determination of the environment on the microphone response of the technology; 3. In the absence of professional acoustic test equipment, according to The type of microphone used, and the predetermined corrections for the electrostatic actuator used to determine the free field response or the sound pressure response of the microphone; 4. a technique applied to high frequencies that can not be covered by acoustic excitation calibration methods. |
GB/T 20441.6-2017: Electroacoustics -- Measurement microphones -- Part 6: Electrostatic actuators for determination of frequency response ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Electroacoustics. Measurement microphones. Part 6. Electrostatic actuators for determination of frequency response
ICS 17.140.50
A59
National Standards of People's Republic of China
Electro - acoustic measuring microphones Part 6.
Electrostatic exciter for measuring frequency response
Part 6.Electrostaticactuatorsfordeterminationoffrequencyresponse
(IEC 61094-6.2004, IDT)
Posted.2017-11-01
2018-05-01 implementation
General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
China National Standardization Administration released
Directory
Foreword Ⅲ
1 Scope 1
2 Normative references 1
3 Terms and definitions 1
4 Reference environmental conditions 2
5 Electrostatic exciter works 2
5.1 Overview 2
5.2 static pressure 3
5.3 Electrostatic exciter response 4
6 Electrostatic exciter design 5
6.1 Overview 5
6.2 Design 5
7 Confirm 6
7.1 Overview 6
7.2 Measurement repeatability 6
7.3 Coherence of a given type of electrostatic actuator 6
7.4 Electrostatic exciter response level and sound pressure response level of the consistency of the difference 6
8 Electrostatic exciter response measurement 7
8.1 Electrostatic exciter response measurement system 7
8.2 uncertainty component 8
9 Electrostatic exciter application 9
9.1 Overview 9
9.2 Measurement system frequency response test 9
9.3 Measurement of microphone environmental characteristics of measuring system 9
9.4 Determination of free-field frequency response and sound pressure frequency response 9
9.5 Electrostatic exciter vhf response measurement 10
Appendix A (informative) Example of electrostatic actuator design 11
A.1 Electrostatic exciter for WS1 type microphones 11
A.2 Electrostatic exciter for WS2 microphone 12
A.3 Electrostatic exciter that forms integral part of the boot
Appendix B (Informative) Electrostatic exciter response measuring device 14
Appendix C (Informative) Typical Uncertainty Analysis 15
C.1 Introduction 15
C.2 Analysis 15
C.3 Synthesis Uncertainty and Extended Uncertainty 16
Appendix D (Informative) Typical Measurement Microphone free field, the difference between the sound pressure and the electrostatic actuator response 18
Figure 1 principle of the microphone and electrostatic actuator 3
Fig.2 lumped parameter model of the measuring microphone excited by the electrostatic exciter 5
Figure A.1 Example of electrostatic exciter for WS1 type microphone
Figure A.2 Example 12 of electrostatic exciter for WS2 type microphones
Figure A.3 Example of an electrostatic exciter that forms an integral part of a microphone boot
Figure A.4 Example of electrostatic exciter in conjunction with weather protection 13
Figure B.1 Typical device for measuring the response of a microphone electrostatic actuator 14
Figure D.1 shows an example of the difference between the relative sound pressure frequency response and the electrostatic exciter frequency response of four different types of measuring microphones.
WS1P (a) and WS1F (b) with a nominal sensitivity of -26dB (referenced to 1V/Pa) and nominal sensitivity
Is WS2P (c) and WS2F (d) 18 of -38dB (referenced to 1V/Pa)
Figure D.2 WS1, WS2 and WS3 Microphones Relative Free-field Frequency Response vs. Electrostatic Exciter Frequency Response Without Guard
Example of difference between 18
Figure D.3 WS2 microphone relative free-field frequency response and electrostatic exciter frequency response with model-related shield
Example 19 of the difference
Figure D.4 Add the model-dependent free field and electrostatic actuator difference shown in Figure D.3 to the microphone's electrostatic actuator response
Example 19 b) of obtaining a relative free-field frequency response on a)
Table C.1 Uncertainty 16
Foreword
GB/T 20441 "electro-acoustic measuring microphone" is divided into 8 parts.
--- Part 1. Laboratory standard microphone specifications;
--- Part 2. The primary method of reciprocal sound pressure calibration of laboratory standard microphones;
--- Part 3. Reciprocal technique for the free field calibration of laboratory standard microphones method;
--- Part 4. Working standard microphone specifications;
--- Part 5. Working standard microphone sound pressure calibration comparison method;
--- Part 6. Electrostatic exciters used to determine the frequency response;
--- Part 7. Laboratory standard microphone free field and sound pressure field sensitivity of the difference between;
--- Part 8. Determination of working standard microphones free field sensitivity comparison method.
This section GB/T 20441 Part 6.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This section uses the translation method is equivalent to using the international standard IEC 61094-6.2004 "Measuring microphones Part 6. Used to determine the frequency of sound
Should be the electrostatic actuator. "
The documents of our country that are consistent with the corresponding international documents that are normative references in this section are as follows.
--- GB/T 20441.1-2010 Electroacoustics measuring microphones Part 1. Laboratory Standard Microphone Specification (IEC
61094-1.2000, IDT);
--- GB/T 20441.3-2010 Electro-acoustic measuring microphone Part 3. The use of reciprocity technology laboratory standard microphone
The free-field calibration of the primary method (IEC 61094-3.1995, IDT);
--- JJF1059.1-2012 Evaluation and Expression of Uncertainty in Measurement (ISO /IEC GUIDE98-3.2008 Uncertainty
ofmeasurement-Part 3.Guidetotheexpressionofuncertaintyinmeasurement).
This section made the following editorial changes.
--- For ease of reference, an increase of 9.2 in the reference document "IEC 61672-1" footnote.
Please note that some of this document may be patentable. The issuing agencies of this document do not bear the responsibility of identifying these patents.
This part is proposed by the Ministry of Industry and Information Technology of the People's Republic of China.
This part of the National Electroacoustic Standardization Technical Committee (SAC/TC23) centralized.
This section is drafted. Hengyang Hengyi Electric Co., Ltd., Beijing reputation Acoustic Technology Co., Ltd., Hangzhou Aihua Instrument Co., Ltd.
Third Institute of China Electronics Technology Group Corporation, China Institute of Metrology.
The main drafters of this section. Liu Xiang Heng, Tan Teng, Wu Qunli, Zhang Shaodong, Han Jie, Niu Feng.
Electro - acoustic measuring microphones Part 6.
Electrostatic exciter for measuring frequency response
1 Scope
GB/T 20441 provisions of this section.
--- Electrostatic exciters with conductive diaphragm microphone design guidelines;
--- Electrostatic exciter confirmation method;
--- Determination of microphone electrostatic actuator response method.
This section applies to electrostatic exciter applications, including the following.
--- Detection of microphone frequency response changes in technology;
--- Determination of the impact of the environment on the microphone response technology;
--- In the absence of professional acoustic test equipment, according to the type of microphone used and the use of electrostatic actuator pre-determined
Correction of the microphone to determine the free field response or sound pressure response of the technology;
--- Applied to the acoustic excitation calibration methods can not be covered by high-frequency technology.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
IEC 61094-1 Measurement Microphone Part 1. Laboratory Standard Microphone Specification (Measurement Microphones-
Part 1.Specifications for laboratory standard microrophones)
IEC 61094-2 Measurement microphones - Part 2. Primary method of sound pressure calibration of laboratory standard microphones using reciprocity techniques
(Measurementmicrophones-Part 2.Primarymethodforpressurecalibrationoflaboratorystandard
microphonesbythereciprocitytechnique)
IEC 61094-3 Measurement microphones Part 3. Primary side calibration of free-field calibration of laboratory standard microphones using reciprocity techniques
(Measurementmicrophones-Part 3.Primarymethodforfree-fieldcalibrationoflaboratorystand-
ardmicrophonesbythereciprocitytechnique)
IEC 61094-5 Measurement microphones Part 5. Working standard Microphone sound pressure calibration comparison method (Measurementmi-
crophones-Part 5.Methodsforpressurecalibrationofworkingstandardrophonesbycompari-
son
ISO /IEC GUIDEEXPRESS.1995 Measurement Uncertainty Guide [Guidetotheexpressionofuncer-
taintyinmeasurement (GUM)]
3 Terms and definitions
IEC 61094-1 defines the following terms and definitions apply to this document.
3.1
Electrostatic exciter electrostaticactuator
A device for determining the frequency response of a microphone comprising a conductive rigid plate placed near the microphone diaphragm,
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 20441.6-2017_English be delivered?Answer: Upon your order, we will start to translate GB/T 20441.6-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 20441.6-2017_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 20441.6-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|