US$274.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 20111.1-2015: Electrical insulation systems -- Procedures for thermal evaluation -- Part 1: General requirements -- Low-voltage Status: Valid GB/T 20111.1: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 20111.1-2015 | English | 274 |
Add to Cart
|
3 days [Need to translate]
|
Electrical insulation systems -- Procedures for thermal evaluation -- Part 1: General requirements -- Low-voltage
| Valid |
GB/T 20111.1-2015
|
| GB/T 20111.1-2006 | English | 559 |
Add to Cart
|
3 days [Need to translate]
|
Procedures for thermal evaluation of electrical insulation -- Part 1: General requirements low pressure
| Obsolete |
GB/T 20111.1-2006
|
PDF similar to GB/T 20111.1-2015
Basic data | Standard ID | GB/T 20111.1-2015 (GB/T20111.1-2015) | | Description (Translated English) | Electrical insulation systems -- Procedures for thermal evaluation -- Part 1: General requirements -- Low-voltage | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | K15 | | Classification of International Standard | 29.080.30 | | Word Count Estimation | 14,117 | | Date of Issue | 2015-07-03 | | Date of Implementation | 2016-02-01 | | Older Standard (superseded by this standard) | GB/T 20111.1-2006 | | Quoted Standard | GB/T 11021-2007; IEC 60505-2004; IEC 60216-4-1; IEC 60216-5; IEC 60493-1 | | Adopted Standard | IEC 61857-1-2008, IDT | | Regulation (derived from) | National Standard Announcement 2015 No.22 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This Standard specifies the electrical insulation system (EIS) - Thermal evaluation and testing procedures for general identification, established testing procedures to be evaluated EIS EIS performance and benchmark comparison. This Standard applies to voltage 1000 V and below, the heat factor is the main factor of the aging of existing or proposed EIS used in electrotechnical products. |
GB/T 20111.1-2015: Electrical insulation systems -- Procedures for thermal evaluation -- Part 1: General requirements -- Low-voltage ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Electrical insulation systems Procedures for thermal evaluation Part 1.. General requirements Low-voltage
ICS 29.080.30
K15
National Standards of People's Republic of China
Replacing GB/T 20111.1-2006
Electrical insulation systems - Procedures for thermal evaluation
Part 1. General requirements for low-voltage
Part 1. Generalrequirements-Low-voltage
(IEC 61857-1.2008, IDT)
Issued on. 2015-07-03
2016-02-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Introduction Ⅲ
Introduction Ⅳ
1 Scope 1
2 Normative references 1
3 Terms and definitions
4 Overview 2
4.1 Test procedures before 2
4.2 basis of assessment and identification of 3
4.3 Specific requirements 3
5 test 3
5.1 Overview 3
5.2 Description 3
5.3 Number of test 3
6 Test procedures 4
6.1 Overview 4
6.2 The initial screening test 4
4 6.3 Thermal aging
6.4 Pre-diagnosis of mechanical stress 5
6.5 Other pre-diagnostic requirements 5
6.6 wet exposure 5
6.7 Dielectric diagnostic test 6
6.8 Other diagnostic tests 6
7 analysis, reporting and grading 6
7.1 Failure Criterion 6
7.2 Method of determining the life of 6
7.3 Extrapolation of data 6
7.4 8 report results
Reference 9
Foreword
GB/T 20111 "Electrical insulation systems - Procedures for thermal evaluation" contains the following sections.
--- Part 1. General requirements for low-voltage;
--- Part 2. Particular requirements for generic models scattered around the winding applications;
--- Part 3. Specific requirements for encapsulated coil models scattered around the winding electrical insulation systems (EIS).
This section GB/T 20111 Part 1.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This Part replaces GB/T 20111.1-2006 "electrical insulation Procedures for thermal evaluation - Part 1. General requirements for low-voltage", and
GB/T 20111.1-2006 compared, in addition to editorial changes, the major technical changes are as follows.
--- Unified will "electrical insulation" to "Electrical insulation systems";
--- Remove the "Table 1" (see 2006 edition 3.4);
--- Remove the "EIS temperature index" is defined (see 2006 edition 3.5);
--- Remove the "EIS relative temperature index" is defined (see 2006 edition 3.6);
--- Increased "EIS estimate heat index" is defined (see 3.5);
--- Increased "EIS relative thermal index" is defined (see 3.6);
--- Remove the "footnote a" (see 2006 edition 4.3);
--- Modify the desired heat-resistant grade 120 ℃ high temperature corresponding to the point (see Table 1, Table 2 of the 2006 edition);
--- Added "Table 2" (see Table 2).
This section uses the translation method is equivalent to using IEC 61857-1.2008 "Procedures for thermal evaluation of electrical insulation systems - Part 1. General requirements
Low pressure. "
Consistency correspondence with international standards in this section of our standards of reference are as follows.
--- GB/T 11026.4-2012 heat resistance, electrical insulating materials - Part 4. Ageing ovens - Single - chamber ovens (IEC 60216-
4-1.2006, IDT);
--- GB/T 11026.7-2014 heat resistance, electrical insulating materials - Part 7. Determine the electrically insulating material is relatively resistant means
Number (RTE) (IEC 60216-5.2008, IDT);
The test results based on a normal distribution. --- GB/T 21223.1-2015 aging test statistical analysis Guide Part 1
Methods (IEC 60493-1.2011, IDT) on the basis of average.
This part is proposed by the China Electrical Equipment Industrial Association.
This part of the National Electrical insulation materials and insulation systems assessment Standardization Technical Committee (SAC/TC301) centralized.
This part manufactured by Shanghai Electric Apparatus Research Institute, Shandong Qilu Motor Co., Ltd., Beijing Electrical Machinery Industry Technology Research Institute of Economy,
Beijing Beizhong Steam Turbine Co., Ltd., Shanghai electrical equipment testing is responsible for drafting.
The main drafters of this section. Zhao Chao, Zhang Shengde, Liu Yali, Li Jinliang, Wei Jingsheng, Liufeng Juan, Huanghui Jie.
This section replaces the following previously issued as follows.
--- GB/T 20111.1-2006.
Introduction
This section provides a standard test procedure, according to IEC 60505 by comparing the electrical insulation system (EIS) to evaluate life expectancy
Estimated EIS.
One kind EIS contains many different components, the choice of ingredients should be able to withstand all kinds of electric generating electrical products in different parts of the structure,
Mechanical and thermal stresses. The useful life of the EIS process depends on the combination of components, each component and interaction between the components of the overall EIS
Electrical properties, mechanical properties of the role. Therefore, the provisions of a representative of all the electrical products test is not possible. IEC equipment technical committee
Have responsibilities under test and the test procedures to meet their specific application requirements. Through this technology between the Committee and other technical committees
Cooperation to continue the work to develop a series of parts, each set forth a particular test and/or applications.
This section allows only approximate comparison, and so can not be fully determined to any characteristic of a particular EIS, which can only be based full-featured extensions
Operating experience to be obtained.
Electrical insulation systems - Procedures for thermal evaluation
Part 1. General requirements for low-voltage
1 Scope
This section GB/T 20111 specifies the electrical insulation systems (EIS) Universal thermal evaluation and testing procedures for identification, assessment EIS to be established
Test procedures and performance comparison of a reference EIS.
This section applies to voltage 1000V and below, the heat factor is the main factor of the aging of existing or proposed EIS used in electrotechnical products.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 11021-2007 heat resistance, electrical insulation rating (IEC 60085.2004, IDT)
IEC 60505.2004 Assessment of electrical insulation and differential (Evaluationandgualificationofelectricalinsulation
systems)
IEC 60216-4-1 Electrical insulating materials - Thermal resistance - Part 4-1. Ageing ovens - Single - chamber ovens (Electricalinsulating
materials-Thermalenduranceproperties-Part 4-1. Ageingovens-Singlechamberovens)
IEC 60216-5 Electrical insulating materials - Thermal resistance - Part 5. Determination of relative thermal index of electrical insulating materials (RTE) [E-
lectricalinsulating materials-Thermalenduranceproperties-Part 5. Determination ofrelative
thermalenduranceindex (RTE) ofaninsulatingmaterial]
The average basis of establishing normal distribution in the test results. IEC 60493-1 aging test statistical analysis Guide Part 1
Methods (Guideforthestatisticalanalysisofageingtestdata-Part 1 on. Methodsbasedonmeanvalues
ofnormalydistributedtestresults)
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1
Electrical insulation systems electricalinsulationsystem; EIS
Electrical equipment used in combination with the conductive portion together comprise one or more electrically insulating material (EIM) is insulated.
Note. In accordance with IEC 60505.2004 different temperature index (ATE/RTE, in accordance with IEC 60216-5) The EIM can be combined into EIS, the heat level may be higher
Or less than any single component heat levels.
3.2
Be evaluated EIS candidateEIS
They are assessed in order to determine the heat capacity of the EIS.
3.3
Reference EIS referenceEIS
Known record of operating experience or recognized comparative functional assessment as the basis for assessment and identified the EIS.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 20111.1-2015_English be delivered?Answer: Upon your order, we will start to translate GB/T 20111.1-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 20111.1-2015_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 20111.1-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 20111.1-2015?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 20111.1-2015 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|