HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

GB/T 19381-2015 English PDF

US$319.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 19381-2015: Physical function requirements and testing for pharmaceutical closures of butyl rubber
Status: Valid

GB/T 19381: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 19381-2015English319 Add to Cart 3 days [Need to translate] Physical function requirements and testing for pharmaceutical closures of butyl rubber Valid GB/T 19381-2015
GB/T 19381-2003English919 Add to Cart 4 days [Need to translate] General methods of test for medical closures of butyl rubber Obsolete GB/T 19381-2003

PDF similar to GB/T 19381-2015


Standard similar to GB/T 19381-2015

GB 24788   GB 24786   GB 24788   GB/T 36796   

Basic data

Standard ID GB/T 19381-2015 (GB/T19381-2015)
Description (Translated English) Physical function requirements and testing for pharmaceutical closures of butyl rubber
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard G45
Classification of International Standard 83.140.99
Word Count Estimation 15,153
Date of Issue 2015-05-15
Date of Implementation 2015-10-01
Older Standard (superseded by this standard) GB/T 19381-2003
Quoted Standard GB 15811; ISO 8362-1; ISO 8362-3; ISO 8362-4; ISO 8362-6; ISO 8536-1; ISO 8536-3; ISO 8536-7
Adopted Standard ISO 8871-5-2005, MOD
Regulation (derived from) National Standard Announcement 2015 No. 15
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This Standard specifies the vial supporting the use of medicinal butyl rubber stoppers by the physical performance requirements and test methods for injection or infusion needle puncture puncturing. This Standard applies to medicinal butyl rubber stoppers.

GB/T 19381-2015: Physical function requirements and testing for pharmaceutical closures of butyl rubber


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Physical function requirements and testing for pharmaceutical closures of butyl rubber ICS 83.140.99 G45 National Standards of People's Republic of China Replacing GB/T 19381-2003 Medicinal butyl rubber stoppers physical performance requirements and test (ISO 8871-5.2005, Elastomericpartsforparenteralsandfordevicesfor pharmaceuticaluse-Part 5. Functionalrequirementsandtesting, MOD) Issued on. 2015-05-15 2015-10-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard replaces GB/T 19381-2003 "Common test methods for medicinal butyl rubber stoppers," compared with the GB/T 19381-2003 Main To change the following. --- The standard name was changed to "medicinal butyl rubber stoppers physical performance requirements and test"; --- The scope changed to "This standard specifies the vial and supporting the use of medicinal butyl rubber stopper by injection or infusion needle puncture wear Physical performance requirements and test methods "thorn time (see Chapter 1, Chapter 1, 2003 edition); --- Increased terms and definitions (see Chapter 3); --- Removed classification determination (see 2003 edition Chapter 3, Chapter 4); --- Remove the biological performance requirements, chemical performance requirements, the physical performance requirements of hardness, increased puncture force cork puncture fall Crumbs, self-sealing container and cork and adhesion requirements (see Chapter 4, Chapter 5, 2003 edition); --- Increased test preparation stoppers (see Chapter 5); --- Remove the test methods, packaging, storage, marking and labeling (see Chapter 8, 9, 2003 edition); --- Revised Appendix A ~ Appendix N, increase the informative Appendix E (see Appendix A ~ Appendix E, 2003 edition Appendix A ~ Appendix N). This standard uses the redrafted Law Amendment uses ISO 8871-5.2005 (E) "parenterals and pharmaceutical instruments elastic - Part 5. Functional requirements and testing. " This standard and ISO 8871-5.2005 technical differences are as follows. --- The standard name was changed to "medicinal butyl rubber stoppers physical performance requirements and test"; --- In Chapter 1, an increase in the scope of the words "or an infusion puncture"; --- In Chapter 2 normative references added "ISO 8536-1" medical infusion apparatus - Part 1. Infusion glass bottles " ISO 8536-3 "medical infusion apparatus - Part 3. aluminum caps for infusion bottles" and ISO 8536-7 "medical infusion apparatus 7 Part I. infusion bottle plastic combinations covered ""; --- In Chapter 4, add a butyl rubber stopper transfusion requirements; --- In 5.1, an increase of butyl rubber infusion stopper sampling; --- 5.3, increasing the "cork in 30min then cooled to room temperature, remove the flask. Water was decanted and the stopper at 60 ℃ By drying 60min, stored in a sealed glass container for use. "Content; --- Increased "can be 200mm/min speed," content A.3.2.2, A.4.1.4a) in; --- Appendix A added butyl rubber infusion Spikes Test; --- In B.3.1.7 will "filter pore size of 0.5μm" to "medium speed filter paper"; --- In B.3.1.8 will "filter, capable of accommodating a filter pore size of 0.5μm" to "Buchner funnel to accommodate speed filter paper"; --- Increasing the butyl rubber infusion Spikes off the crumbs tests in Appendix B; --- Increase butyl rubber stopper infusion self-sealing container and adhesion testing in Appendix C; --- Increase the informative Appendix E. The standard proposed by China Petroleum and Chemical Industry Association. This standard by the National Rubber and rubber products latex products Standardization Technical Committee Technical Committee (SAC/TC35/SC4) Centralized. This standard was drafted. Westlands Jiangsu New Medicinal Materials Co., Ltd., Shenzhen City Medical Device Testing, Zhejiang Quality Inspection Bureau Graduate School, Jiangyin Exit Inspection and Quarantine, National Latex Products Quality Supervision and Inspection Center, China Zhuzhou Chemical Industry Research and Design Institute of rubber. The main drafters of this standard. Hua Yimin, Liu Hongwei, Wu Jianqin, Jiang Peng, Zhao Chengzhe, Wang Wei, Yang Han, Shen, Zhao New, Zhu Yingying, East is high, Zheng Sanyang, Deng Zhi, Wang Jinying. Medicinal butyl rubber stoppers physical performance requirements and test

1 Scope

This standard specifies the vial and supporting the use of medicinal butyl rubber stoppers to physical performance or infusion needle puncture puncturing Requirements and test methods. This standard applies to medicinal butyl rubber stoppers. NOTE. ISO 8536-2 and ISO 8536-6 specifies the injection needle through the functional testing methods.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB 15811-time use of sterile needles (GB 15811-2001, eqv ISO 7864.1993) ISO 8362-1 Injection containers and accessories - Part 1. tubular glass injection bottle (Injectioncontainersandaccessories- Part 1. Injectionvialsmadeofglasstubing) Part 3 ISO 8362-3 Injection containers and accessories. injection vials aluminum cap (Injectioncontainersandaccessories- Part 3. Aluminiumcapsforinjectionvials) ISO 8362-4 Injection containers and accessories - Part 4. Injection molded glass bottles (Injectioncontainersandaccessories- Part 4. Injectionvialsmadeofmouldedglass) ISO 8362-6 Part 6 Injection containers and accessories. injection bottles plastic composite cap (Injectioncontainersandacces- sories-Part 6. Capsmadeofaluminium-plasticscombinationsforinjectionvials) ISO 8536-1 Infusion equipment - Part 1. Infusion glass bottles (Infusionequipmentformedicaluse-Part 1. Infusionglassbottles) ISO 8536-3 Infusion equipment - Part 3. Aluminium caps for infusion bottles (Infusionequipmentformedicaluse-Part 3. Aluminiumcapsforinfusionbottles) ISO 8536-7 Infusion equipment - Part 7. Infusion bottle with a plastic composite cap (Infusionequipmentformedical use-Part 7. Capsmadeofaluminium-plasticscombinationsforinfusionbottles)

3 Terms and Definitions

The following terms and definitions apply to this document. 3.1 Piercing penetrability The force required to pierce the cork. 3.2 Puncture off the crumbs fragmentation Pierce the rubber particles produced by the process. 3.3 Self-sealing self-sealing Needle piercing the cork out, the stopper reseal effect.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 19381-2015_English be delivered?

Answer: Upon your order, we will start to translate GB/T 19381-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 19381-2015_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 19381-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 19381-2015?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 19381-2015 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.