HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

GB/T 19216.31-2008 English PDF

US$399.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 19216.31-2008: Tests for electric or optical fibre cables under fire conditions -- Circuit integrity -- Part 31: Procedures and requirements for fire with shock -- Cables of rated voltage up to and including 0.6/1 kV
Status: Obsolete
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 19216.31-2008English399 Add to Cart 3 days [Need to translate] Tests for electric or optical fibre cables under fire conditions -- Circuit integrity -- Part 31: Procedures and requirements for fire with shock -- Cables of rated voltage up to and including 0.6/1 kV Obsolete GB/T 19216.31-2008

PDF similar to GB/T 19216.31-2008


Standard similar to GB/T 19216.31-2008

GB/T 12706.3   GB/T 12706.4   GB/T 19666   GB/T 29631   GB/T 19216.3   GB/T 19216.1   

Basic data

Standard ID GB/T 19216.31-2008 (GB/T19216.31-2008)
Description (Translated English) Tests for electric or optical fibre cables under fire conditions -- Circuit integrity -- Part 31: Procedures and requirements for fire with shock -- Cables of rated voltage up to and including 0.6/1 kV
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K13
Classification of International Standard 29.060.20
Word Count Estimation 10,133
Date of Issue 2008-12-31
Date of Implementation 2009-11-01
Quoted Standard GB/T 13539.5-1999; GB/T 19216.12-2008; GB/T 19216.21-2003
Adopted Standard IEC 60331-31-2002, IDT
Regulation (derived from) Announcement of Newly Approved National Standards No. 23 of 2008 (No. 136 overall)
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the rated voltage 0. 6/1kV and below the line need to maintain the integrity of cables burning under defined conditions and subjected to mechanical shock test procedures and performance requirements, and provides time for the fire. This section is intended for testing cable outer diameter greater than 20mm. This section provides sample preparation methods, continuity checking devices, electrical testing procedures, method of burning cables and mechanical shock generation method, and provides for evaluation of test results required. This section applies to low-voltage power cables and control cables with a rated voltage. Note: Although the scope of this section is limited to large constant voltage 0. 6/1kV and below electrical systems, but the manufacturer and the purchaser agrees, and equipped with appropriate fuses, the program can also be used for rated

GB/T 19216.31-2008: Tests for electric or optical fibre cables under fire conditions -- Circuit integrity -- Part 31: Procedures and requirements for fire with shock -- Cables of rated voltage up to and including 0.6/1 kV



---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Tests for electric or optical fibre cables under fire conditions Circuit integrity Part 31.. Procedures and requirements for fire with shock Cables of rated voltage up to and including 0.6/1 kV ICS 29.060.20 K13 National Standards of People's Republic of China GB/T 19216.31-2008/IEC 60331-31.2002 Circuit integrity under fire conditions in electric cables - Part 31. for fire with shock - Test procedure and requirements --- Rated voltage 0.6/1 and the following cables k Vp (IEC 60331-31.2002, Testsforelectriccablesunderfireconditions- Circuitintegrity-Part 31. Proceduresandrequirementsforfirewithshock- Cablesofratedvoltageuptoandincluding0.6/1kV, IDT) Posted 2008-12-31 2009-11-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Introduction Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 Sample 1 5 continuity test unit 2 6 Test Procedure 2 7 Performance Requirements 3 8 Repeat the test procedure 3 9 Test report 3 GB/T 19216.31-2008/IEC 60331-31.2002

Foreword

GB/T 19216 "in electric cables under fire conditions - Circuit integrity" is divided into six sections. --- Part 11. Test equipment --- flame temperature not lower than 750 ℃ \u200b\u200bseparately for the fire; Applying an impact test apparatus --- flame temperature of not lower than 830 ℃ for fights;. --- Part 12 --- Part 21. Procedures and requirements --- rated voltage 0.6/1.0kV and below cable; --- Part 23. Procedures and requirements --- data cable; --- Part 25. Procedures and requirements --- fiber optic cable; --- Part 31. for fire with shock - Test procedure and requirements --- rated voltage 0.6/1kV and below cable. This section GB/T 19216 of Part 31. This section identical with IEC 60331-31.2002 "cables under fire conditions - Circuit integrity - Part 31. applying for fights Plus the impact of the test procedures and requirements --- rated voltage 0.6/1kV and below cable "(in English). For ease of use, this section made the following editorial changes. --- This part name is amended as. "In the electric cables under fire conditions - Circuit integrity - Part 31. impulse applied for fights Hit test procedures and requirements --- rated voltage 0.6/1kV and below cable "; --- This part corresponds to the name, the English name changed to. "Testsforelectricoropticalfibrecablesunderfire conditions-Circuitintegrity-Part 31. Proceduresandrequirementsforfirewithshock-Cables ofratedvoltageuptoandincluding0.6/1kV "; --- Remove the IEC 60331-31.2002 Foreword and Introduction; --- With a decimal point "." Instead of a comma as the decimal point "." This part is proposed by the China Electrical Equipment Industrial Association. This part of the National Standardization Technical Committee Wire and Cable (SAC/TC213) centralized. This part of the unit responsible for drafting. Shanghai Electric Cable Research Institute. Participated in the drafting of this section. Sichuan Star Cable Co., Ltd., Shanghai Shenghua Cable (Group) Co., Ltd. Jinlong Yu Group Limited Secretary of Jiangsu New Remote Cable Co., Ltd., Shanghai-Wuxi City Wire and Cable Co., Ltd. Wuxi Jiangnan Cable. The main drafters of this section. Gong Guoxiang, Sheng Wu, Wen Jinhai Lu technology only, Xueyuan Hong money Xiaojuan, Xia Yafang. This section first release. GB/T 19216.31-2008/IEC 60331-31.2002 Circuit integrity under fire conditions in electric cables - Part 31. for fire with shock - Test procedure and requirements --- Rated voltage 0.6/1 and the following cables k Vp

1 Scope

This section GB/T 19216 specifies the rated voltage 0.6/1kV and below the need to maintain the integrity of the cable lines in specific conditions Fire and mechanical shock test procedures and performance requirements, and provides time for the fire. This section is intended for diameter greater than 20mm test cable. This section provides sample preparation, continuity checking devices, electrical test procedures, methods of burning cables and mechanical shock generated Method, and provides the results of the assessment requirements. This section applies to low-voltage power cables and control cables with a rated voltage. NOTE. Although this section is limited to the scope of application of rated voltage 0.6/1kV and below the cables, but the manufacturer and the purchaser agrees, and is equipped with the appropriate fuse After the device, the procedure can also be used below the rated voltage of 3.3kV and cables.

2 Normative references

The following documents contain provisions which, through reference GB/T 19216 in this section constitute provisions of this section. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section. GB/T 13539.5-1999 Low-voltage fuses - Part 3. unskilled personnel Supplementary requirements for fuses (mainly used Fuses for household and similar applications) - Examples of standardized fuses (idt IEC 60269-3-1.1994) GB/T 19216.12-2008 in electric cables under fire conditions - Circuit integrity - Part 12. Apparatus --- Applying an impact flame temperature not lower than 830 ℃ for the fights (IEC 60331-12.2002, IDT) GB/T 19216.21-2003 in Part 21 Circuit integrity under fire conditions - cable or fiber optic cable. To test procedure and Seeking --- rated voltage 0.6/1.0kV and below cables (IEC 60331-21.1999, IDT) 1997 application development and basic safety publications, safety publications and similar security publications. IEC Guide 104

3 Terms and Definitions

The following terms and definitions apply to this section. 3.1 When under fire and prescribed burning time, it can continue to run in the state the ability to specify.

4 Sample

4.1 Sample Preparation Take a length of not less than 1500mm finished cable as a sample, and at each end of the cable sheath or strip about the outer 100mm Sheath. At each end of the cable, should properly handle each conductor for electrical connection, and should be separated from each other to avoid the exposed conductor GB/T 19216.31-2008/IEC 60331-31.2002

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 19216.31-2008_English be delivered?

Answer: Upon your order, we will start to translate GB/T 19216.31-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 19216.31-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 19216.31-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.