GB/T 19212.9-2016: Safety of transformers, reactors, power supply units and combinations thereof -- Part 9: Particular requirements and tests for transformers and power supply units for bells and chimes
Status: Valid

GB/T 19212.9: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 19212.9-2016English259 Add to Cart 3 days [Need to translate] Safety of transformers, reactors, power supply units and combinations thereof -- Part 9: Particular requirements and tests for transformers and power supply units for bells and chimes Valid GB/T 19212.9-2016
GB 19212.9-2007English439 Add to Cart 3 days [Need to translate] Safety of power transformers, power supply units and similar devices -- Part 9: Particular requirements for bell and chime transformers Obsolete GB 19212.9-2007

PDF similar to GB/T 19212.9-2016


Standard similar to GB/T 19212.9-2016

GB/T 19212.5   GB/T 10228   GB/T 8286   GB/T 19212.2   GB/T 19212.14   GB/T 19212.1   

Basic data

Standard ID GB/T 19212.9-2016 (GB/T19212.9-2016)
Description (Translated English) Safety of transformers, reactors, power supply units and combinations thereof -- Part 9: Particular requirements and tests for transformers and power supply units for bells and chimes
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K41
Word Count Estimation 13,127
Date of Issue 2016-08-29
Date of Implementation 2017-03-01
Older Standard (superseded by this standard) GB 19212.9-2007
Regulation (derived from) National Standard Announcement 2016 No.14
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

GB/T 19212.9-2016: Safety of transformers, reactors, power supply units and combinations thereof -- Part 9: Particular requirements and tests for transformers and power supply units for bells and chimes



---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Safety of transformers, reactors, power supply units and assembly thereof - Part 9. Particular requirements and tests for transformers and power supply units for bells and chimes ICS 29.180 K41 National Standards of People's Republic of China Replacing GB 19212.9-2007 Transformers, reactors, power supplies, and combinations thereof Part 9. bells and bells and transformers Special requirements and tests for power supply units Safetyoftransformers, reactors, powersupplyunitsandcombinationsthereof- Part 9. Particularrequirementsandtestsfortransformersandpowersupply (IEC 61558-2-8..2010, Safetyoftransformers, reactors, powersupplyunitsand combinationsthereof-Part 2-8. Particularrequirementsandtestsfor transformersandpowersupplyunitsforbelsandchimes, MOD) 2016-08-29 release.2017-03-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of the People 's Republic of China China National Standardization Management Committee released Directory Preface III 1 Scope 1 2 normative reference document 1 3 Terms and definitions 2 4 General requirements 2 5 General description of the test 2 6 rated 2 Category 2 8 signs and other information 3 9 electric shock protection 3 10 Change of input voltage setting value 3 11 load output voltage and output current 3 12 no-load output voltage 4 13 short circuit voltage 4 14 fever 4 15 short circuit and overload protection 5 16 mechanical strength 5 17 Protection against dust, solid foreign matter and moisture harmful access 5 18 Insulation resistance, dielectric strength and leakage current 5 19 Structure 5 20 components 6 21 internal wiring 6 22 power connection and other external flexible cable or cord 6 23 External conductor terminal 7 24 Protective earthing device 7 25 screws and connections 7 26 creepage distance, electrical clearance and through insulation distance 7 27 heat resistance, flame resistance and resistance to tracing 7 28 rust 7 Appendix 8 Reference 9

Foreword

GB/T 19212 "Safety of transformers, reactors, power supply units and their combinations" 1) The following sections are included. 1) Some of the series of standards are under the heading "Safety of power transformers, power supplies, reactors and similar products", and some are in the "supply voltage For 1100V and below the safety of transformers, reactors, power supply units and similar products "under the heading, some of which are in the" Transformer, Reactor, Source device and its portfolio of products "under the heading, the future release of this series of standard titles may be modified. - Part 1. General requirements and testing; - Part 2. Particular requirements and tests for the general purpose separation transformer and the power supply for the separation transformer; Part 3. special requirements and tests for controlling the power supply of transformers and built-in transformers; - Part 4. Particular requirements and tests for gas and fuel burner ignition transformers; - Part 5. Particular requirements and tests for power supply units for isolation transformers and internal isolation transformers; - Part 6. Particular requirements and tests for power supply units for use in transformers and razors for razors; - Part 7. Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers; - Part 8. Particular requirements and tests for transformers and power supplies for toys; - Part 9. Particular requirements and tests for bells and bells and transformers and power supply units; Part 10. Particular requirements and tests for transformers and power supply units for Class III portable tungsten filament lamps; - Part 13. Particular requirements for constant voltage transformers; - Particular requirements and tests for power supply units for autotransformers and autotransformers - Part 14. - Part 15. Particular requirements and tests for power supply units for regulators and internal regulators; - Part 16. Particular requirements for isolating transformers for power supply in medical places; - Part 17. Special tests and requirements for transformers for switchgear and switching power supply units; - Part 20. Particular requirements and tests for interference attenuating transformers; - Part 21. Particular requirements and tests for small reactors; - Part 24. Particular requirements for transformers for construction sites. This part is part 9 of GB/T 19212. This part is based on GB/T 19212.1-2016, which is required Used in conjunction with GB/T 19212.1-2016. This part is the GB/T 19212.1-2016 the corresponding chapter, the article to add and modify, In order to convert the contents of GB/T 19212.1-2016 into the contents of this section. This section adds new to GB/T 19212.1-2016 The contents are numbered starting from 101. This part is drafted in accordance with the rules given in GB/T 1.1-2009. This section replaces GB 19212.9-2007 "Safety of power transformers, power supply units and similar products Part 9. Bells and clocks Transformer special requirements ". Compared with GB 19212.9-2007, the main technical changes are as follows. --- Standard name changed to "Safety of transformers, reactors, power supply units and their combinations Part 9. Bell and bell transformers and electrical Special requirements and tests for source devices "; - Added the provisions of Chapter 1 (see Chapter 1); - the definition of the term "bell and bell transformer" has been modified (see 3.1.101); - the term "normal operation" and its definition are deleted (see.2007 edition 3.102); - the provisions of the rated output voltage limit for independent transformers are added (see 6.101); - amended by means of work (see 7.5); - the provisions of the heat test method have been modified (see 14.1); - modified the application of the supply voltage for the short circuit test (see 15.101); - to modify and increase the structure of the provisions (see Chapter 19); - Appendix C and Appendix D were deleted (see Appendix C and Appendix D for the.2007 edition); - Added Appendix F (see Appendix F). This part uses the re-drafting method to modify IEC 61558-2-8..2010 "Transformers, reactors, power supply units and their combinations Part 2-8. Particular requirements and tests for bells and bells and transformers and power supply units ". There are technical differences between this part and IEC 61558-2-8..2010, all of which are due to the matching criteria in this section GB/T 19212.1-2016 and IEC 61558-1..2009 in Chapter 2 of the technical differences arising there. Please note that some of the contents of this document may involve patents. The issuer of this document does not assume responsibility for the identification of these patents. This part is made by China Electrical Equipment Industry Association. This part of the national small power transformers, reactors, power supply and similar products Standardization Technical Committee (SAC/TC418) Go back. This part of the drafting unit. Shenyang Transformer Research Institute Co., Ltd., National Radio and Television Product Quality Supervision and Inspection Center, Shanghai Quality Supervision and Inspection Technology Research Institute, Ministry of Industry and Information Technology Electronics Fifth Institute 赛 Bao quality and safety testing center, Shanghai immigration inspection Bureau of Electrical and Mechanical Products Detection Technology Center, Pearl Electric Co., Ltd., Zhongshan City Poly gold Electronics Co., The main drafters of this part. Lin Ran, Zhang Yafang, Yu Yimin, Sun Jianlong, Zhang Hong, Liang Hui, Mao Qiyu, Lin Junrong, Ding Xi. This part of the previous version of the standard to replace the release of the situation. --- GB 19212.9-2007. Transformers, reactors, power supplies, and combinations thereof Part 9. bells and bells and transformers Special requirements and tests for power supply units

1 Scope

This clause of GB/T 19212.1-2016 is replaced by the following. This part of GB/T 19212 specifies the safety of the bells and bells and the power supply of the bells and bells begging. Transformers with electronic circuits are also included in this section. Note 1. Safety requirements include electrical, temperature and mechanical aspects. Unless otherwise specified, the following "transformers" include bell and bell transformers and power supply devices with bells and bells. This part applies to stand-alone, single-phase, air-cooled (self-cooling or air-cooled), independent or supporting dry-type transformers. The windings can be Encapsulated or non-encapsulated. This standard applies to transformers and power supply units (linear). This part is used in conjunction with GB 19212.17 switch type power supply unit. It is also suitable for power supply with internal operating frequency exceeding 500Hz. Set. When the requirements of the two standards are inconsistent, the more stringent standards are preferred. Rated power supply voltage does not exceed AC 250V, rated power frequency does not exceed 500Hz. This standard applies to the internal operating frequency is not super Over 500Hz transformer and linear power supply device. Rated output should not exceed 100VA. No-load output voltage does not exceed AC 33V or no ripple DC 46V, rated output voltage does not exceed AC 24V or no ripple DC 33V. Bell and bell transformers are usually scheduled for power supply for short-term, heavy-duty household electroacoustic signal devices and other similar devices. Note 2. Partial load can be used as illumination. This standard does not apply to external circuits and components that are intended to be connected to the input and output terminals of the transformer. When the installation procedure or the final product standard requirements between the circuit for the double insulation or reinforced insulation, you can use this part of the change Pressure device. Note 3. Normally, the transformer is intended to be used in conjunction with the equipment to meet the functional requirements of the equipment to provide a different voltage from the supply voltage. Its electric shock The protection may be provided (or improved) by means of other components of the supplied equipment, such as a housing. The components of the output circuit can be connected to the input circuit or guaranteed Protect the ground. This part applies to transformers with special equipment, the scope of which is determined by the relevant standards. Note 4. The following should be noted. - to avoid the shell and the shell components such as mold, pests, termites, daily radiation and ice and other external protective measures should also be considered; --- Transformer transport, storage and work of the different conditions should also be considered; - Additional requirements for other suitable standards and national procedures may be used for transformers intended for use in special environments, such as tropical environments. Note 5. With the development of transformer technology in the future, it may be necessary to increase the upper limit of the transformer frequency. By that time, this part can be used as a guide.

2 normative reference documents

The clause of GB/T 19212.1-2016 applies except for the following referenced documents. The following additions are added to this chapter.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 19212.9-2016_English be delivered?

Answer: Upon your order, we will start to translate GB/T 19212.9-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 19212.9-2016_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 19212.9-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 19212.9-2016?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 19212.9-2016 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.