GB/T 19065-2011: Economical operation for electric boiler system
Status: Valid

GB/T 19065: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 19065-2011English349 Add to Cart 3 days [Need to translate] Economical operation for electric boiler system Valid GB/T 19065-2011
GB/T 19065-2003English199 Add to Cart 2 days [Need to translate] Economic operation of electric heating boiler system [including MODIFICATION 1] Obsolete GB/T 19065-2003

PDF similar to GB/T 19065-2011


Standard similar to GB/T 19065-2011

GB 19044   GB 18613   GB 19153   GB 19762   GB 20943   GB 17167   

Basic data

Standard ID GB/T 19065-2011 (GB/T19065-2011)
Description (Translated English) Economical operation for electric boiler system
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard F01
Classification of International Standard 27.010
Word Count Estimation 15,166
Date of Issue 2011-09-29
Date of Implementation 2012-03-01
Older Standard (superseded by this standard) GB/T 19065-2003
Quoted Standard GB/T 1576; GB/T 4272; GB 5749; GB/T 8175; GB/T 10180; GB 50041; JB/T 10393
Regulation (derived from) National Standards Bulletin 2011 No. 14
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the electrical heating boiler system economic operation of the terminology and definitions, basic requirements, operational management, technical and economic indicators, test and calculation methods and assessment. This standard applies to power-frequency power supply is 380V class, rated evaporation is greater than or equal to 0. 07t/h of water as the medium of electrically heated steam boilers and rated thermal power is greater than or equal to 0. 05MW electrically heated hot water boiler systems engineering design, construction and operation.

GB/T 19065-2011: Economical operation for electric boiler system

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Economical operation for electric boiler system ICS 27.010 F01 National Standards of People's Republic of China Replacing GB/T 19065-2003 Electric heating boiler system economic operation Issued on. 2011-09-29 2012-03-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Preface Ⅰ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 Basic requirements 3 Operation and management 3 5 6 4 technical and economic indicators 7 Measurement and Calculation Method 5 7.1 boiler thermal efficiency test and calculation method 5 7.2 The average energy efficiency of the system test and calculation methods 5 7.3 Regenerative systems run average valley electricity utilization test and calculation methods 5 7.4 Hot water heat accumulator heat retaining performance test and calculation method 5 8 examination 6 Appendix A (informative) electric heating boiler system log table 7 Appendix B (normative) economic operation of electric heating boiler system evaluation form 10

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard replaces GB/T 19065-2003 "electric heating boiler system economic operation." This standard compared with GB/T 19065-2003, the main changes as follows. --- Information about the definition of "electric heating boiler system economic operation" and "hot water thermal storage device," etc., and some of the terminology and definitions Adjustment, perfect (3.1,3.2,3.3,3.4); --- Normative references increase the GB 5749 "drinking water health standards", GB 50041 "boiler room design specifications" GB/T 8175 "equipment and pipeline insulation design guide", "steam boiler safety technology supervision order", "hot water boiler safety technology Supervision Regulations "," Stationary Pressure Vessel Safety Technology Supervision "," high-energy special equipment supervision and management of energy-saving measures "and" special Species Equipment Safety Supervision Regulations "; --- The technical requirements to the basic requirements, an increase of three requirements, and some provisions were supplemented, modified (4.2,4.3,4.4,4.6, 4.7,4.8,4.9,4.11); --- Regulations on the operation, delete the two, added two, some provisions were added, modified, and will run records classified project List (5.2,5.3,5.6,5.8,5.10,5.11 Table 1); --- Raised electric heating boiler thermal efficiency of the index value will be run average valley electricity utilization metrics to distinguish the whole amount of regenerative and storage components Thermal, the addition of hot water heat accumulator heat retention performance indicators (6.1,6.3,6.4); --- Increased heat retaining hot water thermal storage device performance test and calculation method (7.4); --- The evaluation principles modified to assessment, and assessment content has been adjusted to increase the assessment of implementation and evaluation unit of data measurement techniques Expiration date of the provisions of (8.1,8.2,8.5); --- Formulate a unified assessment record format "electric heating boiler system log table" (Appendix A) and the "electric heating boiler system economic operation Line evaluation form "(Appendix B). This standard by the National Standardization Technical Committee for Energy and Management (SAC/TC20) centralized. This standard drafting units. China National Institute of Standardization, Xi'an Energy Research, Xi'an Special Equipment Inspection and Testing Institute, Zhejiang special set Preparation of Inspection and Research Institute, Wenzhou Special Equipment Inspection Center, Hangzhou Huayuan frontline Energy Equipment Co., Ltd., Hai Yu Water Treatment Technology Co., really The company, Zhejiang Teflon heat Technology Co., Ltd., Xi'an Tirisfal Thermal Technology Co., Ltd. Shaanxi Branch Department of Thermal Technology Co., Ltd., Shaanxi Province Boiler plant Weinan, Shaanxi Longyuan Electric Branch Co., Shaanxi IAC Industries Limited. The main drafters of this standard. Jia Tieying, Zhiliang, a Defang, heroic Chen, Xu Guofu, Wang Yazhen, Deng Libin, Wang Hong, Chen Gang, Zhang Union, Sun Road, Tang Xuezong, Qi Haifeng, Zhaoguo Ling. Electric heating boiler system economic operation

1 Scope

This standard specifies the terms and definitions of economic operation of electric heating boiler system, basic requirements, operational management, technical and economic indicators, testing and Calculation methods and assessment. This standard applies to the power supply is 380V rating frequency, Rated evaporation is greater than or equal to 0.07t/h of water as a medium of electric heating Heat and steam boilers rated thermal power greater than or equal to 0.05MW electrically heated hot water boiler systems engineering design, construction and operation.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 1576 industrial boiler water quality GB/T 4272 General technical equipment and pipeline insulation GB 5749 drinking water health standards GB/T 8175 equipment and pipeline insulation design guidelines Performance testing procedures GB/T 10180 industrial boilers Thermal GB 50041 boiler room design specifications JB/T 10393 electric heating boiler technology Condition Steam Boiler Safety Technology Supervision Hot Water Boiler Safety Technology Supervision Safety Technology Supervision of Stationary Pressure Vessels High energy saving special equipment supervision and management measures Special Equipment Safety Supervision Regulations

3 Terms and Definitions

JB/T 10393 and defined by the following terms and definitions apply to this document. 3.1 Electric heating boiler system electricboilersystem By an electric heating boilers and pumps, heat storage devices, control devices and other related equipment, facilities consisting of self-powered switch to the boiler room heating mains Between the valve system. Press composition divided into direct supply systems and regenerative system. 3.1.1 Supplying electric heating boiler system instantsupplyelectricboilersystem In the external or internal electric heating boilers are not provided thermal storage device, only by electric boilers for thermal heating units or direct the purposes of heating equipment Heating boiler system. 3.1.2 Storage electric heating boiler system heataccumulationelectricboilersystem In the external or internal electric heating boiler with a heat accumulator, the heat generated by the boiler can be stored and timely supply of thermal units or

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 19065-2011_English be delivered?

Answer: Upon your order, we will start to translate GB/T 19065-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 19065-2011_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 19065-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 19065-2011?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 19065-2011 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.