HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

GB/T 18858.1-2012 English PDF

US$234.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 18858.1-2012: Low-voltage switchgear and controlgear -- Controller-device interfaces (CDIs) -- Part 1: General rules
Status: Valid

GB/T 18858.1: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 18858.1-2012English234 Add to Cart 3 days [Need to translate] Low-voltage switchgear and controlgear -- Controller-device interfaces (CDIs) -- Part 1: General rules Valid GB/T 18858.1-2012
GB/T 18858.1-2002English399 Add to Cart 3 days [Need to translate] Low-voltage switchgear and control equipment controller -- Device interface (CDI) -- Part 1: General Obsolete GB/T 18858.1-2002

PDF similar to GB/T 18858.1-2012


Standard similar to GB/T 18858.1-2012

GB/T 16935.3   GB/T 18802.31   GB/T 16935.4   GB/T 11918.6   GB/T 18858.7   GB/T 18858.3   

Basic data

Standard ID GB/T 18858.1-2012 (GB/T18858.1-2012)
Description (Translated English) Low-voltage switchgear and controlgear -- Controller-device interfaces (CDIs) -- Part 1: General rules
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K30
Classification of International Standard 29.130.01
Word Count Estimation 12,165
Older Standard (superseded by this standard) GB/T 18858.1-2002
Quoted Standard GB 4824-2004; GB/T 17626.2-2006; GB/T 17626.3-2006; GB/T 17626.4-2008; GB/T 17626.5-2008; GB/T 17626.6-2008; GB/T 17799.2-2003; IEC 60947-1-2007
Adopted Standard IEC 62026-1-2007, IDT
Regulation (derived from) National Standards Bulletin No. 28 of 2012
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard applies to low-voltage switchgear and control equipment with the controller (such as a programmable controller, a personal computer, etc.) between the interfaces. This section does not apply to IEC/SC65C study called higher-level fieldbus in

GB/T 18858.1-2012: Low-voltage switchgear and controlgear -- Controller-device interfaces (CDIs) -- Part 1: General rules


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Low-voltage switchgear and controlgear Controller-device interfaces (CDIs) Part 1. General rules ICS 29.130.01 K30 National Standards of People's Republic of China Replacing GB/T 18858.1-2002 Low-voltage switchgear and control equipment Controller - Device Interface (CDI) Part 1. General Low-voltageswitchgearandcontrolgear-Controler-deviceinterface (CDI) - Part 1. Generalrules (IEC 62026-1.2007, IDT) Issued on. 2012-11-05 2013-02-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Preface Ⅰ Introduction Ⅱ 1 Scope 1 2 Normative references 1 3 Terms and definitions 2 4 Category 3 5 Features 3 5.1 CDI element 3 5.2 Interface 3 5.3 Topology 3 3 5.4 Information Interchange 5.5 Properties 3 6 product information 4 6.1 Installation, Operation, and Maintenance Manual 4 6.2 Description 4 6.3 Flag 4 6.4 Protection Level 4 7 normal use, installation and transportation 4 7.1 General 4 7.2 normal conditions of use 4 7.3 Transportation and storage conditions 5 7.4 Installation 5 8 structure and performance requirements 5 8.1 General requirements 5 8.2 Electromagnetic compatibility (EMC) 5 9 Test 6 9.1 General requirements 6 9.2 Type test 6 9.3 Electromagnetic Compatibility Test 7

Foreword

GB/T 18858 "Low-voltage switchgear and control equipment Controller - Device Interface" is divided into three parts. --- Part 1. General; --- Part 2. Actuator Sensor Interface (AS-i); Part --- Section 3. DeviceNet. This section GB/T 18858 Part 1. This section drafted in accordance with GB/T 1.1-2009 given rules. This Part replaces GB/T 18858.1-2002 "Low-voltage switchgear and control equipment Controller - Device Interface (CDI) Part 1 Score. General ", compared with the GB/T 18858.1-2002, the main changes are as follows. --- Chapter 2, "Normative References" section updated version of the standard reference; --- Update Table 1 "Immunity Requirements" part of the test pattern and test level, using the current version of the requirements specified in the standard, including. a) RFEMS trials increase 1.4GHz ~ 2GHz frequency test range; b) electrical fast transient burst immunity test explicitly for all cable comprising CDI communication medium, the test level Peak voltage 1kV/repetition frequency 5kHz; for all other cable and port, the test voltage peak level 2kV/repetition frequency 5kHz. This section identical with IEC 62026-1.2007 "low-voltage switchgear and control - Controller - device interfaces - Part 1. General. " This part of IEC 62026-1.2007 compared to the main editorial changes made the following. --- Remove the IEC 62026-1.2007 Foreword; --- "This standard" be replaced by "of this section." Consistency correspondence between this part of international documents and normative references of our files are as follows. --- GB 14048.1-2006 Low-voltage switchgear and control equipment Part 1. General (IEC 60947-1.2007, MOD). This part is proposed by the China Electrical Equipment Industrial Association. The low-voltage electrical part by the National Standardization Technical Committee (SAC/TC189) centralized. This section is responsible for drafting unit. Shanghai Electric Apparatus Research Institute, Shanghai Electric Technology Co., Ltd. Electric Division. Participated in the drafting of this section. France and Thailand Electric (Jiangsu) Co., Ltd., Changshu Switch Manufacturing Co., Ltd., Shanghai Electric Co. Shares Companies People's Electric Factory, Shanghai People Enterprise Group Electric Co., Ltd. Wenzhou, Shanghai electrical equipment testing by China Quality Certification Center, Zhejiang Tengen Electric Company. The main drafters of this section. Huang Jing Ye, Ji Yu Hui. The drafters of some of the participants. Ding Gaofeng, Shao Jianguo, Feng Jun, Jin Ling Man, Nguyen Gyeongju, Zhang Ying, Jiaying Wei, Li Peng. This part of the standard replaces the previous editions are. --- GB/T 18858.1-2002.

Introduction

Within the scope of this controller - Device Interface (CDI) range includes control systems, factory automation and process automation with the work Industry CDI. CDI has expanded the scope of industrial use to meet the special needs of users, but none CDI can meet all the requirements. The formation of multi Kinds of patterns for CDI CDI is due to the physical properties, uses, wide range of information content and structural requirements. In order to meet the distance section Condition number of points and the environment, result in different physical requirements CDI signal line and the regulatory function is also different. While CDI technology changing, this section specifies the general element, common interface and environmental requirements. Related to the CDI common Standardized regulations can help users seeking technical comparison and selection to meet specific use of the distance, the number of nodes, data processing and The apparatus of claim. This section through the preparation of a dedicated CDI standard that provides a common structure, and the inclusion of special features and capabilities of the interface, so the CDI Selection process can be simplified. Chapter 1 - Chapter 8 included CDI standard specifies basic requirements for a summary trial provisions included in Chapter 9. Characteristics of standardized CDI also simplifies the preparation of industrial control system software advanced features (such as management control, operator interface and control strategies Programming software) tasks. In order to complete this standard and easy to use, require special CDI standards, which have been included in GB/T 18858 series of standards other parts. Low-voltage switchgear and control equipment Controller - Device Interface (CDI) Part 1. General

1 Scope

This section applies to the interface between the low-voltage switchgear and control equipment and a controller (such as a programmable controller, a personal computer, etc.). This section does not apply to a higher level of industrial fieldbus communication networks called by the IEC /SC65C research. GB/T 18858 provisions of this part of the definition of the rules for industrial CDI, elements and basic performance requirements. On all types of CDI Standard features can be used as the basic requirements included in this section focus. In determining the various CDI all the requirements and test requires the use of the following two major documents. a) of this section, the relevant standards include various types of CDI referred to as "Part 1"; b) GB/T 18858 series of standards dedicated CDI parts. If the General NA, CDI-specific criteria may not use, or if the basic requirements are not suitable for special occasions, CDI-specific criteria may Of General supplemented, but the content of specific standards should not be contrary to its essential requirements, unless there is sufficient technical justification. Note. For vehicles equipped with CDI products, the product specific requirements set out in the relevant product standard. In addition to the requirements of this section to the provisions of the relevant product standards Shall apply.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB 4824-2004 industrial, scientific and medical (ISM) radio-frequency equipment - Electromagnetic disturbance characteristics - Limits and methods of measurement (IEC / CISPR11.2003, IDT) GB/T 17626.2-2006 Electromagnetic compatibility - Testing and measurement techniques - Electrostatic discharge immunity test (IEC 61000-4-2.2001, IDT) GB/T 17626.3-2006 Electromagnetic compatibility - Testing and measurement techniques RFEMS test (IEC 61000-4- 3.2002, IDT) GB/T 17626.4-2008 Electromagnetic compatibility - Testing and measurement techniques - Electrical fast transient burst immunity test (IEC 61000- 4-4.2004, IDT) GB/T 17626.5-2008 Electromagnetic compatibility - Testing and measurement techniques - Surge (impact) immunity test (IEC 61000-4-5. 2005, IDT) GB/T 17626.6-2008 Electromagnetic compatibility - Testing and measurement techniques - conducted disturbances induced by RF field immunity (IEC 61000- 4-6.2006, IDT) GB/T 17799.2-2003 Electromagnetic compatibility - Generic standards - Immunity for industrial environments (IEC 61000-6-2.1999, IDT) IEC 60947-1.2007 Low-voltage switchgear and control equipment Part 1. General (Low-voltageswitchgearandcon- torlgear-Part 1. Generalrules)

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 18858.1-2012_English be delivered?

Answer: Upon your order, we will start to translate GB/T 18858.1-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 18858.1-2012_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 18858.1-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 18858.1-2012?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 18858.1-2012 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.