US$739.00 · In stock Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 18853-2015: Hydraulic fluid power filters -- Multi-pass method for evaluating filtration performance of a filter element Status: Valid GB/T 18853: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 18853-2015 | English | 739 |
Add to Cart
|
5 days [Need to translate]
|
Hydraulic fluid power filters -- Multi-pass method for evaluating filtration performance of a filter element
| Valid |
GB/T 18853-2015
|
GB/T 18853-2002 | English | RFQ |
ASK
|
6 days [Need to translate]
|
Hydraulic fluid power filters -- Multi-pass method for evaluating filtration performance of a filter element
| Obsolete |
GB/T 18853-2002
|
PDF similar to GB/T 18853-2015
Basic data Standard ID | GB/T 18853-2015 (GB/T18853-2015) | Description (Translated English) | Hydraulic fluid power filters -- Multi-pass method for evaluating filtration performance of a filter element | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | J20 | Classification of International Standard | 25.220.10 | Word Count Estimation | 35,321 | Date of Issue | 2015-12-31 | Date of Implementation | 2016-07-01 | Older Standard (superseded by this standard) | GB/T 18853-2002 | Quoted Standard | GB/T 786.1; GB/T 14041.1; GB/T 17446; GB/T 17484; GB/T 17486; GB/T 17489; GB/T 18854; GB/T 21540; GB/T 27613; GB/T 28957.1-2012 | Adopted Standard | ISO 16889-2008, MOD | Regulation (derived from) | State Standard Announcement 2015 No.43 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | Summary | This standard specifies the following: a) multiple pass filtration performance tests for hydraulic transmission elements under contaminant continuous injection conditions; b) procedures for the determination of scale capacity, particle filtration and differential pressure characteristics; c) presently applicable to hydraulic pressure Transmission filter test. The filter has an average filtration ratio greater than or equal to 75 for particles less than or equal to 25 ��m in size (c) and less than 200 mg/L for the tank weight at the end of the test; d) the use of ISO Intermediate Test Powder and Annex A Test oil. The test conditions are: 1, the upstream basic weight pollution degree is 3mg/L; the test condition 2, the upstream basic weight pollution degree is 10mg/L; the test condition 3, the upstream basic weight pollution degree is 15mg/Lt; /RTI & gt; |
GB/T 18853-2015: Hydraulic fluid power filters -- Multi-pass method for evaluating filtration performance of a filter element ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Hydraulic fluid power filters.Multi-pass method for filtration skin performance of a filter element
ICS 23.100.60
J20
National Standards of People's Republic of China
Replace GB/T 18853-2002
Hydraulic drive filter
A method of evaluating the filter performance of filter elements
(ISO 16889..2008, MOD)
2015-12-31 released
2016-07-01 implementation
General Administration of Quality Supervision, Inspection and Quarantine of the People 's Republic of China
China National Standardization Management Committee released
Directory
Preface I
Introduction III
1 Scope 1
2 normative reference document 1
3 Terms and definitions 2
4 symbol 3
5 General procedure 4
6 test equipment 4
7 Test instrument accuracy and test conditions of the range of 5
8 Filter performance test circuit verification procedures 6
9 Required information before trial 8
10 Preparation before trial 8
11 Filter Performance Test 10
12 Calculate 11
13 data expression 12
14 Note 13
Appendix A (normative) Basic performance of test oil 16
Appendix B (informative) Guidelines for the design of test systems 18
Appendix C (Informative Appendix) Calculation and Chart Report Example 22
Reference 29
Foreword
This standard is drafted in accordance with the rules given in GB/T 1.1-2009.
This standard instead of GB/T 18853-2002 "hydraulic transmission filter to assess the filter filter performance of multiple pass method", and
GB/T 18853-2002 compared to the main technical changes are as follows.
--- modified version of the normative reference documents ISO 11943 and ISO 4405, using the latest version (see Chapter 2,.2002
Yearbook Chapter 2).
The normative reference document, ASTM D4308, was deleted and included in the references (see Chapter 2 of.2002).
--- modified part of the parameter symbols (see 4.2,.2002 version 4.2).
- increase the particle size (x1, x2) and the particle size (xint) calculated using the interpolation method (see Table 1).
- increased drying requirements and standardized requirements for test powder over.200 g (see 6.3).
- Increased use of antistatic additives (see 10.3.2).
- Increased number of digital processing requirements for the calculation of the average number of particles (see 12.5d)).
--- modified the expression of the average number of the average number of particles in the upper and lower reaches (see 12.7,.2002 edition 12.7).
- Removes the number of weight contaminants for upstream oil samples (see 12.10).
This standard uses the re-drafting method to modify the use of ISO 16889..2008 "hydraulic drive filter filter filter performance evaluation of multiple pass
Method "(English version).
The technical differences between this standard and ISO 16889..2008 are as follows.
- to modify the normative reference documents to meet the technical conditions of our country, the adjustment of the situation is reflected in Chapter 2 "normative reference
File ", the specific adjustments are as follows.
• Replace ISO 1219-1 (see 4.1) with GB/T 786.1 equivalent to the international standard;
• Replace ISO 2942 with equivalent GB/T 14041.1 with international standards (see Chapter 9);
• GB 5598 (see Chapter 3) with GB/T 17446 equivalent to international standards;
• Replace ISO 3722 (see 6.5) with GB/T 17484 equivalent to international standards;
• ISO 3968 (see 6.7.1) is replaced by GB/T 17486 equivalent to the international standard;
• ISO 4021 (see 6.7.1) is replaced by GB/T 17489 equivalent to the international standard;
• GB 11171 (see 4.2) is replaced by GB/T 18854 with an international standard;
• ISO 11943 (see 6.4) with GB/T 21540 equivalent to international standards;
• ISO 4405 is replaced by GB/T 27613 with an international standard (see 6.8);
• Replace ISO 12103-1 (see 6.3) with GB/T 28957.1 with international standard modifications;
- Removes ISO 17889..2008 normative reference file ISO 5725, since this file is only available in the "Appendix D" section
Quotes.
--- increase the test in the 9th test before the test oil viscosity 14mm2/s and 16mm2/s corresponding to the temperature requirements to improve the test
The accuracy of the results.
--- Added A.5 in the domestic oil YH-10, YH-12 and YH-15 as qualified oil to meet the test oil in China
Application.
--- Added footnote to the special function fuel tank symbol in the system schematic of Appendix B, which is marked in GB/T 786.1
Is not specified, so the use of ISO 16889 in the expression.
--- modify the Appendix B of the system schematic diagram of the temperature regulator of the expression symbols, using GB/T 786.1 in the expression of the provisions.
This standard has made the following editorial changes.
- Removed the ISO 16889..2008 information Appendix D, modified the "reference". Because these two aspects of the standard so that the
With the relationship is not, and increased the length of the standard.
This standard is proposed by the China Machinery Industry Federation.
This standard by the National Hydraulic and Pneumatic Standardization Technical Committee (SAC/TC3) centralized.
This standard is responsible for the drafting unit. National Defense Science and Technology Industrial Granularity Level 1 metering station.
This standard participates in the drafting unit. Jiujiang Seven Precision Electromechanical Technology Co., Ltd., Beijing University of Chemical Technology, Xinxiang Pingfei Filter Co., Ltd.
Division, Liming Hydraulic Co., Ltd.
The main drafters of this standard. Du Lifeng, Liu Yong, Lu Hongnan, Li Fangjun, Lu sent Zhong, Ye Ping, Zhang Wan.
This standard replaced the previous version of the standard release.
--- GB/T 18853-2002.
Introduction
In the hydraulic system, the solid particulate contaminants by increasing wear, stuck, siltation, clogging and accelerating oil oxidation deterioration, etc.
And the annex, resulting in reduced reliability, improved failure rate, shorten the life of accessories and other issues. The hydraulic filter is used to control the circulation in the hydraulic system
Of the number of polluted particles, so that the pollution level of oil to meet the hydraulic accessories of the pollution tolerance and the user needs the reliability requirements. in order to
It is advisable to compare the performance of the filter to select the most suitable filter. The performance characteristics of the filter depend on the filter element
(Its filter and geometry) and the filter housing (its structural shape and seal design). In fact, the hydraulic oil carries contaminants continuously
Flows through the filter until the filter flow resistance reaches the pre-set ultimate differential pressure (bypass valve opening pressure or pressure difference set by the differential pressure indicator).
The filter service life (before reaching the limit pressure difference) and the pollution rate at any point in the hydraulic system are related to the rate of increase in pollutants (invasion rate and generation
Rate and the performance of the filter are closely related. Therefore, in the laboratory for the performance evaluation of the filter should be tested for the filter
The device provides a continuous amount of contaminant, and regularly monitors the filtration performance parameters of the filter.
The test should have a degree of reproducibility and reproducibility. The standard test contaminants are the ISO intermediate test specified in ISO 12103-1
Test powder (ISO MTD, ISO 12103-A3). This test powder has a stable uniform particle size distribution and is available all over the world
Can be purchased. The upstream and downstream particle size distribution of the filter should be measured using an automatic particle counter calibrated according to GB/T 18854.
The results of the filter to determine the filter performance. It is difficult to specify the circulation flow that is consistent with the flow variation in the actual hydraulic system
And therefore, in this test method using steady-state conditions as a test case, in order to improve the reproducibility of the test results and reproducibility.
Hydraulic drive filter
A method of evaluating the filter performance of filter elements
1 Scope
This standard specifies the following.
a) hydraulic transmission filter in the continuous injection of pollutants under the conditions of multiple filtration performance test;
b) procedures for determining the scale capacity, particle filtration and differential pressure characteristics;
c) Tests currently applicable to hydraulic drive cartridges. This filter has an average particle size of particles smaller than or equal to 25 μm (c)
Ratio greater than or equal to 75, and the end of the test tank weight pollution degree of less than.200mg/L;
Note. The flow range of the test equipment and the lower limit of the particle size are determined by validation.
d) Tests using ISO intermediate test powder and test oil specified in Annex A.
This standard applies to the following three test conditions.
--- test conditions 1, the upstream basic weight pollution degree of 3mg/L;
--- test conditions 2, the upstream basic weight pollution rate of 10mg/L;
--- test conditions 3, the upstream basic weight pollution degree of 15mg/L.
2 normative reference documents
The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article
Pieces. For undated references, the latest edition (including all modifications) applies to this document.
GB/T 786.1 Fluid drive systems and components - Graphical symbols and circuit diagrams - Part 1. Diagrams for general use and data processing
(GB/T 786.1-2009, ISO 1219-1..2006, IDT)
GB/T 14041.1 Hydraulic filter elements - Part 1. Verification of structural integrity and determination of initial bubble point (GB/T 14041.1-
2007, ISO 2942..2004, IDT)
GB/T 17446 fluid transmission system and component vocabulary (GB/T 17446-2012, ISO 5598..2008, IDT)
GB/T 17484 Identification and control of hydraulic oil sampling containers for purification methods (GB/T 17484-1998, idtISO 3722.
1976)
GB/T 17486 Evaluation of pressure flow characteristics of hydraulic filters (GB/T 17486-2006, ISO 3968..2001, IDT)
GB/T 17489 Hydraulic particle contamination analysis Extraction of liquid samples from working system piping (GB/T 17489-1998, idt
ISO 4021..1992)
GB/T 18854 Calibration of hydraulic drive liquid automatic particle counters (GB/T 18854-2015, ISO 11171..2010,
MOD)
GB/T 21540 hydraulic transmission liquid on-line automatic particle counting system calibration and verification methods (GB/T 21540-2008,
ISO 11943..1999, IDT)
GB/T 27613 Hydraulic transmission - Liquid contamination - Determination of particle contamination by weighing method (GB/T 27613-2011,
ISO 4405..1991, MOD)
GB/T 28957.1-2012 Road vehicles - Test dust for filter evaluation - Part 1. Silica test dust
(ISO 12103-1..1997, MOD)
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 18853-2015_English be delivered?Answer: Upon your order, we will start to translate GB/T 18853-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 18853-2015_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 18853-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 18853-2015?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 18853-2015 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|