US$404.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 18774-2023: Double-capped fluorescent lamp - Safety specifications Status: Valid GB/T 18774: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 18774-2023 | English | 404 |
Add to Cart
|
4 days [Need to translate]
|
Double-capped fluorescent lamp - Safety specifications
| Valid |
GB/T 18774-2023
|
| GB 18774-2002 | English | 444 |
Add to Cart
|
3 days [Need to translate]
|
Double-capped fluorescent lamps -- Safety specifications
| Valid |
GB 18774-2002
|
PDF similar to GB/T 18774-2023
Basic data | Standard ID | GB/T 18774-2023 (GB/T18774-2023) | | Description (Translated English) | Double-capped fluorescent lamp - Safety specifications | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | K71 | | Classification of International Standard | 29.140.30 | | Word Count Estimation | 22,264 | | Date of Issue | 2023-12-28 | | Date of Implementation | 2026-01-01 | | Older Standard (superseded by this standard) | GB 18774-2002 | | Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration |
GB/T 18774-2023: Double-capped fluorescent lamp - Safety specifications---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS 29:140:30
CCSK71
National Standards of People's Republic of China
Replace GB 18774-2002
Safety Specifications for Double-Ended Fluorescent Lamps
(IEC 61195:2014,IDT)
Published on 2023-12-28
Implemented on 2026-01-01
State Administration for Market Regulation
Released by the National Standardization Administration Committee
Table of contents
Preface III
1 Scope 1
2 Normative references 1
3 Terms and Definitions 1
4 Safety requirements 2
5 Rating 7
Appendix A (normative) Lamp holder 12 for torque test of lamps using G5 and G13 lamp bases
Appendix B (Normative) Lamp holder temperature rise test 13
Appendix C (informative) Lamp design parameters 14
Appendix D (normative) Qualification conditions for type testing 15
Appendix E (informative) Ballast design parameters 16
Reference 17
Foreword
This document complies with the provisions of GB/T 1:1-2020 "Standardization Work Guidelines Part 1: Structure and Drafting Rules of Standardization Documents"
Drafting:
This document replaces GB 18774-2002 "Safety Requirements for Double-Ended Fluorescent Lamps": Compared with GB 18774-2002, except for structural adjustments and compilation
In addition to editorial changes, the main technical changes are as follows:
---Added scope description related to photobiological safety (see Chapter 1);
---Added the term "effective ultraviolet radiation power ratio" (see 3:11);
---Added system requirements (see 4:3:3);
--- Added technical requirements related to ultraviolet radiation (see 4:13);
---Added technical requirements for water contact protection of lamp glass bulbs (see 4:14):
This document is equivalent to IEC 61195:2014 "Safety Specification for Double-Ended Fluorescent Lamps":
Please note that some content in this document may be subject to patents: The publisher of this document assumes no responsibility for identifying patents:
This document is proposed by China Light Industry Federation:
This document is under the jurisdiction of the National Lighting Appliances Standardization Technical Committee (SAC/TC224):
This document was drafted by: Guangdong Guangyan Standardization Technology Co:, Ltd:, Beijing Electric Light Source Research Institute Co:, Ltd:, Foshan Quality Metrology
Supervision and Testing Center, Zhejiang An'an Lighting Co:, Ltd:
The main drafters of this document: Zhang Junbin, Zhang Bo, Ping Qingmei, Xu Haibo:
The previous versions of this document and the documents it replaces are as follows:
---First released in:2002 as GB 18774-2002;
---This is the first revision:
Safety Specifications for Double-Ended Fluorescent Lamps
1 Scope
This document specifies the safety requirements for all categories of double-ended fluorescent lamps for general lighting using the following lamp bases: Fa6, Fa8, G5, G13,
2G13, R17d and W4:3×8:5d:
This document describes the manufacturer's demonstration that its products comply with the requirements of this document based on all product evaluations associated with finished lamp inspection records:
specific method of request: This method is also used for product certification: This document establishes in detail the batch inspection procedure, which provides a limited evaluation of the batch:
This document also specifies the photobiological safety requirements according to IEC 62471:
Blue light hazards and infrared hazards are below levels that require labeling:
Note: The qualification conditions of this document only involve safety indicators and do not consider the performance of double-ended fluorescent lamps for general lighting such as luminous flux, color, start-up and operating characteristics:
When using this document see IEC 60081:
2 Normative reference documents
The contents of the following documents constitute essential provisions of this document through normative references in the text: Among them, the dated quotations
For undated referenced documents, only the version corresponding to that date applies to this document; for undated referenced documents, the latest version (including all amendments) applies to
this document:
IEC 60061-1 Lamp caps and holders and specifications for testing interchangeability and safety - Part 1: Lamp caps and holders
Note: GB/T 1406 (all parts) Type and size of lamp holder (IEC 60061-1)
IEC 60061-3 Lampcaps and holders and gauges for testing their interchangeability and safety: Part 3: Gauges (Lampcapsandholders)
Note: GB/T 1483 (all parts) Lamp holder and lamp holder inspection gauge (IEC 60061-3)
tions)
Note: GB/T 10682-2010 Performance requirements for double-ended fluorescent lamps (IEC 60081:2005, NEQ)
IEC 60695-2-10 Fire Hazard Test for Electrical and Electronic Products Part 10: Glow Wire/Hot Wire Basic Test Method Glow Wire
Note: GB/T 5169:10-2017 Fire Hazard Test for Electrical and Electronic Products Part 10: Glow Wire/Hot Wire Basic Test Method Glow Wire Device and
General test method (IEC 60695-2-10:2013, IDT)
Note: GB/T 14044-2008 Performance requirements for ballasts for tubular fluorescent lamps (IEC 60921:2006, MOD)
3 Terms and definitions
The following terms and definitions apply to this document:
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 18774-2023_English be delivered?Answer: Upon your order, we will start to translate GB/T 18774-2023_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 18774-2023_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 18774-2023_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 18774-2023?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 18774-2023 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|