US$474.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 18403.3-2014: Expression of performance of gas analyzers -- Part 3: Paramagnetic oxygen analyzers Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 18403.3-2014 | English | 474 |
Add to Cart
|
3 days [Need to translate]
|
Expression of performance of gas analyzers -- Part 3: Paramagnetic oxygen analyzers
| Valid |
GB/T 18403.3-2014
|
PDF similar to GB/T 18403.3-2014
Basic data Standard ID | GB/T 18403.3-2014 (GB/T18403.3-2014) | Description (Translated English) | Expression of performance of gas analyzers -- Part 3: Paramagnetic oxygen analyzers | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | N53 | Classification of International Standard | 71.040.10 | Word Count Estimation | 24,241 | Date of Issue | 9/3/2014 | Date of Implementation | 2/1/2015 | Quoted Standard | GB/T 18403.1-2001; GB/T 19768-2005; ISO 9001; GB/T 17214.1; GB/T 17214.2; GB/T 17214.3 | Adopted Standard | IEC 61207-3-2002, IDT | Regulation (derived from) | People's Republic of China Announcement of Newly Approved National Standards No. 21 of 2014 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | Summary | This Standard is applicable to the three main methods, these three methods have been described in the introduction. This Standard is applicable to the basic unit and the auxiliary analyzer for indoor and outdoor installation. |
GB/T 18403.3-2014: Expression of performance of gas analyzers -- Part 3: Paramagnetic oxygen analyzers ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Expression of performance of gas analyzers Part 3. Paramagnetic oxygen analyzers
ICS 71.040.10
N53
National Standards of People's Republic of China
Performance of gas analyzers
Part 3. paramagnetic oxygen analyzer
Part 3. Paramagneticoxygenanalyzers
(IEC 61207-3.2002, IDT)
Issued on. 2014-09-03
2015-02-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
Introduction Ⅱ
1 Scope 1
2 Normative references 1
3 Terms and definitions
4 Program Description 4
Performance 4.1 The basic unit and auxiliary equipment 4
4.2 Additional information and performance indicators related to 5
4.3 important projects and performance indicators related to 5
5 6 qualification test procedures
5.1 Introduction 6
5.2 Test Procedure 7
Appendix A (informative) Interference gas 12
Processing method Annex B (informative) Test gas steam 17
References 19
Foreword
GB/T 18403 "performance of gas analyzers" have or plan to release the following sections.
--- Part 1. General;
--- Part 2. Oxygen in gas (high-temperature electrochemical sensors);
--- Part 3. paramagnetic oxygen analyzer;
--- Part 6. Photometric analyzers.
This section GB/T 18403 Part 3.
This section drafted in accordance with the rules of GB/T 1.1-2009 and GB/T 20000.2-2009 given.
This section uses the translation method is equivalent to using IEC 61207-3.2002 "performance of gas analyzers - Part 3. paramagnetic oxygen analyzer
Device. "
Consistency correspondence between this part of international documents and normative references of our files are as follows.
--- GB/T 19001-2008 quality management system requirements (ISO 9001.2008, IDT)
For ease of use, this section made the following editorial changes.
--- A supplement to IEC 61207-3 Corrigendum 1 and 2 of errata.
Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents.
This part is proposed by China Machinery Industry Federation.
This part of the measurement and control of Standardization Technical Committee (SAC/TC124) is administered by the National industrial processes.
This section drafted by. China Instrument Industry Association, Nanjing Analytical Instrument Factory Co., FPI (Hangzhou) Company Limited
Division Sichuan-Chongqing Analytical Instruments Co., Ltd., Beijing North sub-Mai Hake Analytical Instruments Co., Ltd., Beijing Institute of Metrology detection, Shanghai
City Institute of Measurement and Testing Technology, East China University of Technology, Beijing Institute of analysis instruments.
The main drafters of this section. Maya Juan, Xuhuai Ming Wang Sen, Zhu Zhongwen, Qu Changhong, Chen Lan, Chen Zhengsheng, Zhang Bing, Louxing Jun.
Introduction
Paramagnetic oxygen analyzer only partial pressure sensors, rather than the volume concentration of the reaction, is widely used in industry, laboratories and other areas. in
Reference under pressure analyzer rated measuring range of 0% to 1% and 0% to 100%.
Only a few gas paramagnetic (for example. oxygen, nitric oxide and nitrogen dioxide). Oxygen has a strong paramagnetic susceptibility (see Appendix
A), based on the characteristics of oxygen in most industrial applications, it can be designed to have a high specificity of the analyzer, such as measurement of high hydrocarbon background
The oxygen content of the compound.
About paramagnetic oxygen measurement technology has many different descriptions, but commercially available analyzer mainly in the following three ways.
--- Automatic zero balance (magnetic mechanical);
--- Thermal-magnetic or magnetic wind;
--- Pressure (or Quincke) method.
These methods require the sample gas cleaning and drying by heating and other improvements, so easily condensed at low temperatures of the sample gas can be
analysis.
For these reasons, before the sample gas measurement response appropriately.
Performance of gas analyzers
Part 3. paramagnetic oxygen analyzer
1 Scope
GB/T 18403 in this section applies to the three main methods, these three methods have been described in the introduction. This section relates to the basic assist
Unit for indoor and outdoor installation analyzer.
Note. The key security system requirements need to add that this part of the technical performance of the analyzer does not contain this part.
The purpose of this section is.
--- Specifies the terms and definitions paramagnetic gas analyzer features measurement of oxygen in the sample gas;
--- Unified class analyzer features and verification methods;
--- Specifies the test content and test methods for determination of functional characteristics should be carried out;
--- Documents provide the basis for the ISO 9001 quality management standard applications.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 17214 (all parts) industrial process measurement and control equipment - Operating conditions
GB/T 18403.1-2001 performance of gas analyzers - Part 1. General (IEC 61207-1.1994, IDT)
GB/T 19768-2005 process analyzer sample processing system performance indicates (IEC 61115.1992, IDT)
ISO 9001 quality management system requirements (Qualitymanagementsystems-Requirements)
3 Terms and Definitions
GB/T 18403.1-2001 and as defined in the following terms and definitions apply to this document.
3.1
Susceptibility magneticsusceptibility
Measuring the amount of change of the magnetic field strength of the test substance and the vacuum magnetic field intensity, see equation (1).
X =
H1-H
(1)
Where.
X --- susceptibility, dimensionless;
The magnetic field strength H --- vacuum state in amperes per meter (A · m-1);
H1 --- test substance in the magnetic field strength in amperes per meter (A · m-1).
3.1.1
Paramagnetic substance paramagnetism
You can increase the magnetic field strength of the material (X > 0).
3.1.2
Anti (against) a magnetic substance diamagnetism
You can attenuate the magnetic field strength of the material (by H1 \u003cH,所以X\u003c0)。
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 18403.3-2014_English be delivered?Answer: Upon your order, we will start to translate GB/T 18403.3-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 18403.3-2014_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 18403.3-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|