US$329.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 18340.3-2010: Organic geochemical analysis method for geological samples -- Part 3: Determination of saturated hydrocarbon group components in heavy fraction of oil -- Mass spectrometry Status: Valid GB/T 18340.3: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 18340.3-2010 | English | 329 |
Add to Cart
|
3 days [Need to translate]
|
Organic geochemical analysis method for geological samples -- Part 3: Determination of saturated hydrocarbon group components in heavy fraction of oil -- Mass spectrometry
| Valid |
GB/T 18340.3-2010
|
GB/T 18340.3-2001 | English | RFQ |
ASK
|
6 days [Need to translate]
|
Organic geochemical measurements of geological samples -- Method for hydrocarbon types analysis of gasoil saturates fraction by mass spectrometry
| Obsolete |
GB/T 18340.3-2001
|
PDF similar to GB/T 18340.3-2010
Basic data Standard ID | GB/T 18340.3-2010 (GB/T18340.3-2010) | Description (Translated English) | Organic geochemical analysis method for geological samples -- Part 3: Determination of saturated hydrocarbon group components in heavy fraction of oil -- Mass spectrometry | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | D04 | Classification of International Standard | 73.010 | Word Count Estimation | 14,143 | Date of Issue | 2010-11-10 | Date of Implementation | 2011-02-01 | Older Standard (superseded by this standard) | GB/T 18340.3-2001 | Regulation (derived from) | National Standard Approval Announcement 2010 No.8 (Total No.163) | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | Summary | This standard specifies the method of mass spectrometry saturated hydrocarbon family, quantitative calculation and precision requirements. This section applies to heavy petroleum fractions (boiling range 205��C ~ 540��C) Quantitative saturated hydrocarbon fractions of seven kinds of saturated hydrocarbons and aromatic hydrocarbons family one kind of analysis, samples free of olefins, aromatics content of less than 5%. Warning-this part of the staff should be using regular laboratory work experience. This section does not indicate that all possible safety problems. Users are responsible for taking appropriate safety and health practices, and to ensure compliance with the relevant conditions of the national regulations. |
GB/T 18340.3-2010: Organic geochemical analysis method for geological samples -- Part 3: Determination of saturated hydrocarbon group components in heavy fraction of oil -- Mass spectrometry
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Organic geochemical analysis method for geological samples Part 3. Determination of saturated hydrocarbon group components in heavy fraction of oil Mass spectrometry.
ICS 73.010
D04
National Standards of People's Republic of China
Replacing GB/T 18340.3-2001
Organic geochemical analysis of geological samples
Part 3. petroleum heavy fractions of saturated hydrocarbons
Aromatic component mass spectrometry
Part 3. Determinationofsaturatedhydrocarbongroupcomponents
Issued on. 2010-11-10
2011-02-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
GB/T 18340 "organic geochemistry in geological samples analysis methods," There are six sections.
--- Part 1. Light Crude Gas Chromatography;
--- Part 2. Determination of Organic Matter stable carbon isotope isotope mass spectrometry;
--- Part 3. Determination of heavy petroleum fractions Mass Spectrometry saturated aliphatic hydrocarbon component;
--- Part 4. heavy petroleum distillate aromatic aliphatic component mass spectrometry;
--- Part 5. rock and extract crude oil saturated hydrocarbon analysis by gas chromatography;
--- Part 6. Gasoline Hydrocarbon Mass Spectrometry.
This section GB/T 18340 Part 3.
This section of the reference standard American Society for Testing Materials ASTMD2786-91 (2006) "gas oil saturated hydrocarbon fraction hydrocarbons high
Ionizing Voltage Mass Spectrometry. "
This Part replaces GB/T 18340.3-2001 "organic geochemical analysis of geological samples tested heavy petroleum fractions consisting of saturated aliphatic hydrocarbons Mass
Method ", compared with the GB/T 18340.3-2001, the main changes are as follows.
--- By the name of the standard "Organic geochemical measurements of geological samples heavy fraction oil saturated aliphatic hydrocarbon mass spectrometry method of composition" to "geological
Organic geochemical sample analysis methods - Part 3. Determination of mass spectrometry heavy oil "fraction saturated aliphatic hydrocarbon component;
--- Increased caution, warning section;
--- Chapter 1, the original standard range boiling range to 205 ℃ ~ 540 ℃;
--- Original standard has been adjusted the structure and content, and make appropriate editorial changes; sections of the reference ASTMD2786-91
(2006) made the relevant sections of major changes.
This section presents the People's Republic of China Ministry of Land Resources.
This part of the National Standardization Technical Committee under the jurisdiction of Land and Resources.
This standard is drafted by. National Geological Experimental Test Center.
This section is drafted. Wuxi Institute of Petroleum Geology Research Institute of Petroleum Exploration and Development Co., Ltd. China Petroleum & Chemical.
The main drafters of this section. Zhang Zhirong, Zhang canal, Song Xiaoying, Cao Yin.
This part of the standard replaces the previous editions as. GB/T 18340.3-2001.
Organic geochemical analysis of geological samples
Part 3. petroleum heavy fractions of saturated hydrocarbons
Aromatic component mass spectrometry
Warning --- Use this section shall be a person experiences regular laboratory work. This section does not point out all possible security asked
question. Users have the responsibility to take appropriate safety and health practices and to ensure compliance with the conditions relevant national regulations.
1 Scope
This section GB/T 18340 specifies the mass fraction of heavy oil saturated hydrocarbon group components analysis, quantitative calculation and precision
Claim.
This section applies to heavy petroleum fractions (boiling range 205 ℃ ~ 540 ℃) saturated hydrocarbon fraction seven and one kind of aromatic hydrocarbon saturated aliphatic
Quantitative analysis of the components. That no large olefins, aromatics content of less than 5%.
Principle 2
Crude oil is separated by column chromatography, saturated hydrocarbon fraction obtained by direct injection into the mass spectrometer gasification system, the ion source of electronic boom
Strike to give the mixed mass chromatogram saturated hydrocarbon fraction. The mass spectral data of each characteristic peak intensity plus hydrocarbons and post the corresponding inverse matrix system
Multiplication, can be obtained relative content of saturated hydrocarbon group components.
3 Reagents and materials
3.1 perfluorinated kerosene (PFK), perfluoro tributylamine (FC-43) or other known accurate mass reference materials.
3.2 hexadecane. chromatography.
3.3 dichloromethane. AR.
3.4 hexane. AR.
3.5 silica gel. chromatography.
3.6 Alumina. chromatography.
4 instruments and equipment
4.1 MS. having EI ion source and sample mass spectrometer equipped with a direct injection system and data acquisition and processing system.
4.2 Injection system. programmable up to 125 ℃ ~ 350 ℃ (heating rate. 30 ℃/min ~ 130 ℃/min) direct injection system.
4.3 micro syringe or constant volume pipette (1μL ~ 10μL).
4.4 column (length. 40cm ~ 60cm, Nei Jing. 0.8cm ~ 1.2cm).
5 Sample Preparation
Weigh 30mg ~ 50mg crude oil sample with 30mL of n-hexane was dissolved overnight asphaltene precipitation; solution was concentrated to 60 ℃ water bath
1mL ~ 2mL, transferred to a sample containing 2mg 4mg alumina and silica gel chromatography column, rinsed four times with 20mL of n-hexane to give
Saturated hydrocarbon fraction, a saturated hydrocarbon solution was concentrated with 40 ℃ transferred to stoppered vials small opening in the back.
Step 6 Analysis
6.1 Analysis conditions
6.1.1 Quality Resolution. not less than 500.
|