HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (12 Oct 2025)

GB/T 17951.2-2014 English PDF

US$329.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 17951.2-2014: Cold-rolled non-oriented electrical steel strip delivered in the semi-processed state
Status: Valid

GB/T 17951.2: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 17951.2-2014English329 Add to Cart 3 days [Need to translate] Cold-rolled non-oriented electrical steel strip delivered in the semi-processed state Valid GB/T 17951.2-2014
GB/T 17951.2-2002English519 Add to Cart 4 days [Need to translate] Cold-rolled grain non-oriented electrical steel strip (sheet) delivered in the semi-processed state Obsolete GB/T 17951.2-2002

PDF similar to GB/T 17951.2-2014


Standard similar to GB/T 17951.2-2014

GB/T 34215   GB/T 32288   GB/T 2521.1   GB/T 17951   GB/T 38877   

Basic data

Standard ID GB/T 17951.2-2014 (GB/T17951.2-2014)
Description (Translated English) Cold-rolled non-oriented electrical steel strip delivered in the semi-processed state
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard H53
Classification of International Standard 77.040.40
Word Count Estimation 14,187
Date of Issue 6/24/2014
Date of Implementation 4/1/2015
Older Standard (superseded by this standard) GB/T 17951.2-2002
Quoted Standard GB/T 228.1; GB/T 247; GB/T 2521; GB/T 2522; GB/T 2523; GB/T 3655; GB/T 17505; GB/T 18253; GB/T 19289; YB/T 081
Adopted Standard IEC 60404-8-3-2005, MOD
Regulation (derived from) National Standards Bulletin No. 14 of 2014
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This Standard specifies the terms and definitions and a half process cold rolled non-oriented electrical steel, classification, grade, general requirements, technical requirements, test methods, packaging, marking and quality certificate. This Standard ap

GB/T 17951.2-2014: Cold-rolled non-oriented electrical steel strip delivered in the semi-processed state


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Cold-rolled non-oriented electrical steel strip delivered in the semi-processed state ICS 77.040.40 H53 National Standards of People's Republic of China Replacing GB/T 17951.2-2002 Half process cold rolled non-oriented electrical steel (IEC 60404-8-3.2005, Specificationsforindividualmaterials-cold-roled semi-processedstate, MOD) Issued on. 2014-06-24 2015-04-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard replaces GB/T 17951.2-2002 "half process cold rolled non-oriented electrical steel (sheet)." This standard compared with GB/T 17951.2-2002 The main changes are as follows. --- Modify the scope of application; --- Remove the nominal thickness of 0.50mm 50WB500,50WB530,50WB600,50WB700,50WB800 grades; --- Modify the reference heat treatment conditions in the dew point temperature by 35 ℃ adjusted to 20 ℃ ± 2 ℃; --- Increasing the requirements and test methods for the specific average surface roughness; --- Increased testing methods tensile strength and elongation; --- Increasing the insulation coating resistance test method; --- Increasing the numerical rounding rules. This standard uses redrafted law revision adopted IEC 60404-8-3.2005 "half cold rolling process the alloy, non-alloy electrical steel sheet (strip) technology condition". Taking into account China's national conditions, the use of this standard in IEC 60404-8-3.2005 When the following changes. --- About the technical differences have been incorporated into the body and they are involved in terms of the margin of a single vertical line identification. In the data A list of those technical differences and the reasons given in Annex C for reference; --- Grades according to the provisions of GB/T 221 preparation, lists of the Standard Grade with IEC Standard Grade in information in Appendix A of According to the table; --- Lists the provisions of this standard and the control list IEC standard clauses in informative Appendix B; --- Remove the IEC standard foreword; --- Chapter 3. The IEC standard "definition" to "Terms and Definitions"; --- Increase the numerical rounding rules. The standard proposed by China Iron and Steel Association. This standard by the National Steel Standardization Technical Committee (SAC/TC183) centralized. This standard drafting of the main unit. Wuhan Iron and Steel (Group) Corporation, Anshan Iron and Steel Group, Shougang Corporation, Metallurgical Industry Information Standards Institute Study hospital. The main drafters of this standard. Zhu Xiaobo, Liu concentrated Rencui Ying, Ji Chun tube, Sun Maolin, Wang Jun, the first page Ouyang, Li Dong, double yellow, Tao Li, Liu Lixin, IRON AND. This standard replaces the standards previously issued as follows. --- GB/T 17951.2-2002. Half process cold rolled non-oriented electrical steel

1 Scope

This standard specifies the terms and definitions and a half process of cold-rolled non-oriented electrical steel, classification, designation, general requirements, technical requirements, test side Law, packaging, marking and quality certificate. This standard applies to magnetic structure for use in coating or not coating, heat treatment after punching required nominal thickness of 0.50mm, 0.65mm semi-process cold rolled non-oriented electrical steel.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 228.1 tensile testing of metallic materials - Part 1. room temperature test methods (GB/T 228.1-2010, ISO 6892-1. 2009, MOD) General provisions GB/T 247 steel sheet and strip packaging, marking and quality certificate GB/T 2521 cold rolled grain oriented and non-oriented electrical steel (sheet) (GB/T 2521-2008, IEC 60404-8-7.1998, IEC 60404-8-4.1998, MOD) GB/T 2522 electrical steel sheet (strip) surface insulation resistance, coating adhesion test method (GB/T 2522-2007, IEC 60404-11.1999, MOD) GB/T 2523 cold-rolled sheet metal (with) the surface roughness and the peak number of measurement methods (GB/T 2523-2008, SAEJ911- 1998, NEQ) GB/T 3655 with Epstein measuring magnetic properties of electrical steel sheet method (band) (GB/T 3655-2008, IEC 60404-2. 1996, IDT) GB/T 17505 Steel and steel products General technical delivery requirements (GB/T 17505-1998, ISO 404.1992, EQV) GB/T 18253 Steel and steel products inspection document type (GB/T 18253-2000, ISO 10474.1991, EQV) GB/T 19289 electrical steel sheet (strip) density, resistivity and stacking factor of the measurement method (GB/T 19289-2003, IEC 404-13.1995, MOD) Determining rounding and detection values \u200b\u200bYB/T 081 standard metallurgical technical value

3 Terms and Definitions

GB/T in 2521 and defined the following terms apply to this document. 3.1 Semi craft semi-processed Production plants are not final annealing by the user must complete annealing process status. 3.2 The average surface roughness roughnessaverage Arithmetical mean deviation of the roughness profile, that is the arithmetic mean of the roughness profile within sampling length offset absolute units Micron (μm).