US$439.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 17795-2019: Glass wool thermal insulating products for building Status: Valid GB/T 17795: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 17795-2019 | English | 439 |
Add to Cart
|
4 days [Need to translate]
|
Glass wool thermal insulating products for building
| Valid |
GB/T 17795-2019
|
GB/T 17795-2008 | English | 85 |
Add to Cart
|
0--9 seconds. Auto-delivery
|
Glass wool thermal insulating products for building
| Obsolete |
GB/T 17795-2008
|
GB/T 17795-1999 | English | 439 |
Add to Cart
|
4 days [Need to translate]
|
Glass wool thermal insulating products for building
| Obsolete |
GB/T 17795-1999
|
PDF similar to GB/T 17795-2019
Basic data Standard ID | GB/T 17795-2019 (GB/T17795-2019) | Description (Translated English) | Glass wool thermal insulating products for building | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | Q25 | Classification of International Standard | 91.120.10 | Word Count Estimation | 22,292 | Date of Issue | 2019-08-30 | Date of Implementation | 2020-07-01 | Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration |
GB/T 17795-2019: Glass wool thermal insulating products for building---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Glass wool thermal insulating products for building
ICS 91.120.10
Q25
National Standards of People's Republic of China
Replace GB/T 17795-2008
Glass wool products for building insulation
2019-08-30 released
2020-07-01 implementation
State Administration for Market Regulation
Issued by China National Standardization Administration
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard replaces GB/T 17795-2008 "Glass Wool Products for Building Thermal Insulation". Compared with GB/T 17795-2008, except for editability
The main technical changes are as follows.
--- Added the definition of glass wool felt (see 3.1);
---The definition of glass wool board is added (see 3.2);
---Added the definition and classification of glass wool strips (see 3.3 and 4.1.2);
--- Added the definition of formaldehyde-free glass wool products (see 3.4);
--- The definition of the outer cladding of the reflecting surface is deleted (see 3.1 in the.2008 edition);
---Modified the classification of products (see 4.1, see 4.1 of the.2008 edition);
---Modified product marking requirements (see 4.2, see 4.2 of the.2008 edition);
--- Deleted the general requirements (see Chapter 5 of the.2008 edition);
---Modified the size and density allowable deviation requirements (see 5.1.2, see 6.2 of the.2008 edition);
---Added the requirements for slag ball content, moisture content, and mass moisture absorption rate (see 5.1.3, 5.1.4 and 5.1.5);
---Modified the requirements for thermal conductivity and thermal resistance (see Table 4, see Table 1 of the.2008 edition);
---Added requirements for glass wool strips for internal insulation, curtain walls, steel structures, metal surface sandwich panels, and ventilation duct products (see
5.2, 5.3, 5.4, 5.5 and 5.6);
---Added the requirements for the average fiber diameter (5.2.1, 5.3.1, 5.4.1, 5.5.1 and Table 5);
--- Modified the requirements for formaldehyde emission (see 5.2.5 and 5.6.2, see 6.7 of the.2008 edition);
---Added the requirement of water repellency rate (see 5.2.3 and 5.3.3 and 5.6.1);
---Modified the requirements for metal corrosivity (see 5.3.4 and 5.6.4, see 6.6 in the.2008 edition);
---Added anti-mold performance requirements (see Table 5);
---Added optional performance (see 5.7);
---Modified the judgment rules (see 7.4, see 8.4 in the.2008 edition);
---Added anti-fungal test method (see Appendix B).
This standard was proposed by the China Building Materials Federation.
This standard is under the jurisdiction of the National Thermal Insulation Material Standardization Technical Committee (SAC/TC191).
Drafting organizations of this standard. Building Materials Industry Technical Supervision and Research Center, Huamei Energy Conservation Technology Group Glass Wool Products Co., Ltd., Guangzhou
Special Pressure Equipment Inspection and Research Institute, China Building Materials Inspection and Certification Group Co., Ltd., Shanghai Jianke Inspection Co., Ltd., Owens Corning
(China) Investment Co., Ltd., Beijing Building Materials Inspection and Research Institute Co., Ltd., Hebei Green Glass Wool Products Co., Ltd., Chengdu Hanjiang New
Material Technology Co., Ltd., Yingsheng Energy Conservation Group Co., Ltd., Dachang Jinyu Jinhaiyan Glass Wool Co., Ltd., Jiangsu Ecosite New Material
Co., Ltd., Hebei Shenzhou Insulation Building Materials Group Co., Ltd., Hebei Jinwei New Building Materials Co., Ltd., Hebei Gome New Building Materials Co., Ltd.
Company, Armacell Thermal Insulation (Guangzhou) Co., Ltd., Hubei Jiafuda Energy-saving Technology Co., Ltd., Huali Glass Wool (Shanghai) Co., Ltd.
Company, Dongying Huadeli New Material Co., Ltd.
The main drafters of this standard. Jin Fujin, Liu Yingzhuo, Gao Hongquan, Peng Chao, Zhao Junming, Xu Ying, Pan Xiaoying, Zhang Zhi, Chen Xintong, Liu Jia,
Zhang Jun, Gao Shuanglin, Wu Huiguo, Sun Jian, Zhu Yuguo, Tian Hui, Gao Tieyan, Gao Yongtao, Gao Shiyi, Zhang Jianqiang, Zhang Yang, Zhang Yong, Wang Yutao,
Sui Chengxin.
The previous versions of the standard replaced by this standard are as follows.
---GB/T 17795-1999, GB/T 17795-2008.
Glass wool products for building insulation
1 Scope
This standard specifies the classification and marking, technical requirements, test methods, inspection rules, signs, and packaging of glass wool products for building thermal insulation.
Loading, transportation and storage.
This standard is applicable to glass wool products for heat insulation and ventilation ducts of building envelopes.
2 Normative references
The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this article
Pieces. For undated references, the latest version (including all amendments) applies to this document.
GB/T 191 Packaging, Storage and Transportation Graphic Mark
GB/T 4132 Thermal insulation materials and related terms
GB/T 5480 Test method for mineral wool and its products
GB 8624-2012 Classification of burning performance of building materials and products
GB/T 10294 Determination of steady-state thermal resistance and related characteristics of thermal insulation materials. Protective hot plate method
GB/T 10295 Determination of steady-state thermal resistance and related characteristics of insulation materials by calorimeter method
GB/T 10299 Test method for hydrophobicity of thermal insulation materials
GB/T 11835-2016 Rock wool, slag wool and their products for thermal insulation
GB/T 13480 Determination of Compressive Performance of Thermal Insulation Products for Building
GB/T 17146 Test method for water vapor transmission performance of building materials and products
GB/T 17393 Specification for Thermal Insulation Materials for Covering Austenitic Stainless Steel
GB/T 20247-2006 Acoustic measurement of sound absorption in reverberation rooms
GB/T 20313 Thermal performance of building materials and products-Determination of moisture content by drying method
GB/T 29899 Test method for emission of volatile organic compounds in wood-based panels and products
GB/T 32379-2015 Determination of formaldehyde emission from mineral wool and its products
JC/T 469 Glass wool products for sound absorption
3 Terms and definitions
The following terms and definitions defined in GB/T 4132 apply to this document.
3.1
Glass wool felt
A flexible felt-like product made by applying a thermosetting adhesive to glass wool.
3.2
Glass wool board
A self-supporting plate-shaped product with a certain rigidity made by applying a thermosetting adhesive to glass wool.
3.3
Glass wool strip
The glass wool board is cut into slats of a certain width and rotated 90° to form a product.
3.4
Formaldehyde-free glass wool products
Glass wool products made of formaldehyde-free binders (such as acrylic resin binders, starch binders, etc.).
3.5
Water vapor penetration resistant outer coating
The outer covering material with the function of blocking water vapor penetration, such as aluminum foil, polypropylene, etc.
4 Classification and marking
4.1 Classification
4.1.1 According to the type of binder, it is divided into ordinary glass wool products and formaldehyde-free glass wool products.
4.1.2 Divided into. internal insulation, curtain wall, steel structure, metal surface sandwich panel, and glass wool products for ventilation ducts.
4.1.3 According to the form, it is divided into. glass wool board (including composite glass wool board used to make air duct), glass wool felt and glass wool strip.
4.1.4 Divided according to the outer covering.
a) Products without outer covering;
b) Products with outer coating.
---Anti-water vapor penetration outer coating, such as aluminum foil, polypropylene, etc.;
---Non-resistant water vapor penetration outer coating, such as glass cloth, non-woven cloth, etc.
4.1.5 Glass wool products for ventilation ducts can be divided into. external insulation of ventilation ducts, duct lining, and composite ducts for making ducts.
Glass wool board.
4.2 Product marking
Product marking is composed of three parts. product name, standard number, and product technical characteristics.
The product name should include the type and purpose of the binder.
The technical characteristics of the product include. combustion performance level, nominal thermal resistance R (outer cladding), density, size (L (length) × W (width) × T (thickness), single
Bits are mm].
Example 1.Ordinary glass wool products, combustion grade is A (A1), thermal resistance R is 1.5m2·K/W, with aluminum foil outer coating, density is 32kg/m3, size is
12000mm×600mm×50mm glass wool felt for curtain wall, marked as.
Example 2.Formaldehyde-free glass wool products, the combustion grade is A (A2), the nominal thermal resistance R is 1.3m2·K/W, no outer coating, the density is 48kg/m3, and the size is
1200mm×600mm×40mm glass wool board for external insulation of ventilation ducts, marked as.
Note. No "()" after the thermal resistance R means that the product has no outer coating.
5 Technical requirements
5.1 General requirements
5.1.1 Appearance
The surface of the product should be flat, and there should be no scars, stains, or damage that hinder use. For products with an outer coating, the adhesion of the outer coating and the substrate should be flat
Whole and firm.
5.1.2 Allowable deviation of size and density
The allowable deviation of the size and density of the glass wool felt, slab and strip shall meet the requirements of Table 1, Table 2 and Table 3 respectively.
5.3 For curtain wall
5.3.1 Average fiber diameter
Should not be greater than 7.0μm.
5.3.2 Density
The nominal density of glass wool felt should not be less than 16kg/m3; the nominal density of glass wool board should not be less than 32kg/m3.
5.3.3 Hydrophobicity rate
Should not be less than 98.0%.
5.3.4 Corrosion to metals
When used to cover aluminum and steel, the rank sum test method with 90% confidence is adopted, and the rank sum of the control sample should not be less than 21.
5.3.5 Burning performance level
The burning performance of glass wool products without an outer coating should not be lower than the A (A2) level of GB 8624-2012; the burning performance of products with an outer coating
Negotiated by both parties.
5.4 For steel structure
5.4.1 Average fiber diameter
Should not be greater than 7.0μm.
5.4.2 Density
The nominal density of glass wool felt should not be less than 12kg/m3; the nominal density of glass wool board should not be less than 24kg/m3.
5.4.3 Combustion performance level
The burning performance of glass wool products without an outer coating should not be lower than the A (A2) level of GB 8624-2012; the burning performance of products with an outer coating
Negotiated by both parties.
5.5 Glass wool strips for metal sandwich panels
5.5.1 Average fiber diameter
Should not be greater than 10.0μm.
5.5.2 Density
The nominal density should not be less than 32kg/m3.
5.5.3 Compressive strength
Should not be less than 10kPa.
5.5.4 Combustion performance level
Should not be lower than the A (A2) level of GB 8624-2012.
5.7.3 Moisture permeability
The moisture permeability of products with a water vapor-resistant outer coating should not be greater than 6.0×10-9g/(Pa·s·m2).
6 Test method
6.1 General
When testing density, fiber average diameter, slag ball content, moisture content, mass moisture absorption, thermal conductivity, thermal resistance, and water repellency, such as products
With the outer covering layer, it should be tested after removal, and other items are tested in the original form of the product.
6.2 Appearance
Under bright light conditions, visually inspect about 1.0m away from the sample.
6.3 Dimensions and density
According to the provisions of GB/T 5480.Compress the packaged roll felt, loosen the package and turn it over and place it for 4 hours before testing. Calculating density
When, the outer covering should be removed. The measured thickness of felt products is less than the nominal thickness, then the measured thickness is calculated; if the measured thickness is greater than the nominal thickness, then
Calculated according to the nominal thickness. When calculating the density of the board, the thickness is calculated with the measured value. The area of the felt sample should not be less than 1m2 during the test; plates and strips
Select the original size for the size.
6.4 Shot content
According to the provisions of GB/T 5480.
6.5 Moisture content
According to the provisions of GB/T 20313.Drying temperature (105 ± 2) ℃, weigh 3 groups of samples, the mass of each group is (10 ± 2) g.
6.6 Mass moisture absorption rate
According to the provisions of GB/T 5480.
6.7 Construction performance
Follow the provisions of Appendix A.
6.8 Thermal conductivity and thermal resistance
According to GB/T 10294 or GB/T 10295, GB/T 10294 is the arbitration test method. Thermal conductivity of glass wool strip
During the test, the inspection is carried out according to the shape of the glass wool strip. When the width is not enough, it can be spliced to meet the test requirements.
6.9 Average fiber diameter
According to the provisions of GB/T 5480.
6.10 Hydrophobicity rate
According to the provisions of GB/T 10299.
6.11 Combustion performance
According to the provisions of GB 8624-2012.
6.12 Formaldehyde emission
Carry out according to the 1m3 climate box method stipulated in GB/T 32379-2015.
6.13 TVOC release
According to the regulations of GB/T 29899, use 1m3 small release chamber, temperature (23±0.5)℃, relative humidity (50±3)%, production
The product load rate is 1, single side is not sealed, and the air exchange rate is 1 time/h.
6.14 Corrosion to metals
When used for covering austenitic stainless steel, it shall be carried out according to the provisions of GB/T 17393; when used for covering aluminum, copper and steel, it shall be carried out according to GB/T 11835-
The.2016 Appendix F regulations are carried out.
6.15 Compressive strength
According to the provisions of GB/T 13480.The sample size should be 100mm×100mm. If the sample width is less than 100mm, try
The size of the sample is a square with the width of the glass wool strip as the side length, and the thickness is the thickness of the sample, and then the test is carried out. Adopt 50Pa pre-pressure, continuous
Compress the sample until it yields to obtain a compressive strength value.
6.16 Noise reduction coefficient
Carry out according to the regulations of GB/T 20247-2006, and carry out the installation according to the A method of appendix B. Air duct lining board or used to make wind
The test surface of the composite glass wool board of the tube is the use surface in the air duct. For other glass wool products, any side can be tested when there is no outer covering; when there is an outer covering,
The test surface is determined by the client.
6.17 Anti-fungal performance
Perform the test according to the method specified in Appendix B.
6.18 Moisture permeability
Carry out according to the dry method in GB/T 17146, the test conditions are (23±0.5)℃, relative humidity (75±3)%, and the outer coating is facing
The higher humidity side. When the thickness of the product exceeds 30mm, it can be cut to 30mm for testing, but the outer coating should not be damaged.
7 Inspection rules
7.1 Inspection classification
7.1.1 Factory inspection
When the product leaves the factory, it should undergo a factory inspection.
7.1.2 Type inspection
Type inspection should be carried out in one of the following situations.
B.6 Test process
B.6.1 Preparation of culture medium plate
Choose a glass petri dish of ϕ150mm, pour enough PDA into the sterilized petri dish, the thickness of the medium is 3mm~6mm,
Set aside for use (use within 48h).
B.6.2 Vaccination
B.6.2.1 Mold activity control
Place the sterile filter paper flat on the solidified medium, and spray the spore suspension with a sprayer containing the newly prepared mixed spore suspension to make it filled
Spray evenly on the medium and filter paper.
Incubate for 7 days at a temperature of 28°C and a relative humidity of 90% or more. There should be obvious bacterial growth on the filter paper strip, otherwise the test is considered to be no
If it is effective, the test should be repeated.
B.6.2.2 Sample test
Spread the sample on the culture medium with the test side facing up. Spray the spore suspension evenly on the surface of the entire sample and the surrounding medium, each
The test sample should be inoculated with about 0.5 mL of spore suspension. Do 3 parallel tests for each sample.
The above samples are cultured for 28 days at a temperature of (30±2) ℃ and a relative humidity of not less than 90%. If the mold area of the sample is greater than 10%, it can be
End the experiment early.
B.7 Observation of results
After the test is over, take out the sample from the incubator, and directly observe the growth of mold, bacteria, and hypha on the surface of the sample with a 40-fold magnifying glass.
According to the following grades to evaluate and express the degree of mold growth.
Level 0---not long, that is, no mold growth under 40 times magnification;
Level 1-Trace growth, but the growth coverage area is not more than 10%;
Level 2 --- Growth coverage area is greater than 10%.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 17795-2019_English be delivered?Answer: Upon your order, we will start to translate GB/T 17795-2019_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 17795-2019_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 17795-2019_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 17795-2019?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 17795-2019 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|