HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (12 Oct 2025)

GB/T 16895.13-2022 English PDF

US$454.00 ยท In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 16895.13-2022: Low-voltage electrical installations - Part 7-701: Requirements for special installations or locations - Locations containing a bath or shower
Status: Valid

GB/T 16895.13: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 16895.13-2022English454 Add to Cart 4 days [Need to translate] Low-voltage electrical installations - Part 7-701: Requirements for special installations or locations - Locations containing a bath or shower Valid GB/T 16895.13-2022
GB 16895.13-2012English479 Add to Cart 3 days [Need to translate] [GB/T 16895.13-2012] Low-voltage electrical installations -- Part 7-701: Requirements for special installations or locations -- Locations containing a bath or shower Obsolete GB 16895.13-2012
GB 16895.13-2002English399 Add to Cart 3 days [Need to translate] Electrical installations of buildings -- Part 7: Requirements for special installations or locations Section 701: Locations containing a bathtub or shower basin Obsolete GB 16895.13-2002

PDF similar to GB/T 16895.13-2022


Standard similar to GB/T 16895.13-2022

GB/T 29319   GB/T 19964   GB/T 30427   GB/T 16895.22   GB/T 16895.7   GB/T 16895.10   

Basic data

Standard ID GB/T 16895.13-2022 (GB/T16895.13-2022)
Description (Translated English) Low-voltage electrical installations - Part 7-701: Requirements for special installations or locations - Locations containing a bath or shower
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard F12;P63
Classification of International Standard 29.020; 91.140.50
Word Count Estimation 22,255
Date of Issue 2022-12-30
Date of Implementation 2023-07-01
Older Standard (superseded by this standard) GB/T 16895.13-2012
Issuing agency(ies) State Administration for Market Regulation, China National Standardization Administration

GB/T 16895.13-2022: Low-voltage electrical installations - Part 7-701: Requirements for special installations or locations - Locations containing a bath or shower


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS 29.020;91.140.50 CCSP63 National Standards of People's Republic of China Replace GB/T 16895.13-2012 Low-voltage electrical installations Part 7-701.Special installations or place requirements for places with tubs or showers (IEC 60364-7-701.2019, IDT) Posted on 2022-12-30 2023-07-01 implementation State Administration for Market Regulation Released by the National Standardization Management Committee

table of contents

Preface III Introduction V 701 Establishments incorporating baths or showers1 701.1 Scope 1 701.2 Normative references1 701.3 Terms and Definitions1 701.30 Evaluation of general characteristics 2 701.4 Safeguarding 3 701.41 Protection against electric shock3 701.411 Protective measures. automatic disconnection of power supply 3 701.414 Protective measures. use safety extra-low voltage (SELV) and protective extra-low voltage (PELV) 3 701.415 Additional protection4 701.5 Selection and installation of electrical equipment4 701.51 General 4 701.512 Working conditions and external influences4 701.52 Wiring systems5 701.522 Selection and installation of wiring systems based on external influences5 701.53 Equipment for safeguarding, isolating, switching, controlling and monitoring6 701.531 Protective equipment for protection against indirect contact by automatic disconnection of power6 701.101 Area Size Example 6 Reference 15 Figure 1 Remaining wall thickness outside the area6 Figure 2 Area Dimensions. Side View of the Tub 7 Figure 3 Area size. top view of bathtub without fixed partition 8 Figure 4 Area Dimensions. Top View of Bathtub with Fixed Partition 9 Figure 5 Zone 0 and Zone 1 Dimensions. Side View of Shower Zone 10 Figure 6 Dimensions of zone 0 and zone 1.side view of shower area with fixed partition 11 Figure 7 Dimensions of zones 0 and 1.a top view of a shower zone with a fixed outlet close to a corner 12 Figure 8 Dimensions of zone 0 and zone 1.the top view of the shower zone, the fixed water outlet of the shower zone is kept at a certain distance from the corner of the wall 12 Figure 9 Dimensions of zone 0 and zone 1.top view of shower zone with fixed partition 13 Figure 10 Example 14 of a shower area with a door

foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1.Structure and Drafting Rules for Standardization Documents" drafting. GB/T 16895 "Low-voltage electrical installations" has released 5 parts, of which Part 4, Part 5 and Part 7 are divided into several sub-parts part. --- Part 1.Basic principles, general characteristic assessment and definitions; --- Part 4.Safety protection; --- Part 5.Selection and installation of electrical equipment; --- Part 6.Inspection; --- Part 7.Requirements for special installations or locations. This document is subpart 7-701 of GB/T 16895 "Low-Voltage Electrical Installations". Part 7 of GB/T 16895 has been published as Subsection. --- Part 7-701.Requirements for special installations or places A place with a tub or shower; --- Part 7-702.Requirements for special installations or places Swimming pools and fountains; --- Part 7-703.Requirements for special installations or places Rooms and cubicles equipped with sauna heaters; --- Part 7-704.Requirements for special installations or locations Electrical installations for construction and demolition locations; --- Part 7-705.Requirements for special installations or places Agricultural and horticultural facilities; --- Part 7-706.Requirements for special installations or places Conductive places with restricted activities; --- Part 7-710.Requirements for special installations or places Medical places; --- Part 7-711.Requirements for special installations or places for exhibitions, displays and exhibition areas; --- Part 7-712.Requirements for special installations or locations Solar photovoltaic (PV) power systems; --- Part 7-713.Requirements furniture for special installations or places; --- Part 7-714.Requirements for special installations or places Outdoor lighting installations; --- Part 7-715.Requirements for special installations or places Extra-low voltage lighting installations; --- Part 7-717.Requirements for special installations or places Mobile or transportable units; --- Part 7-722.Requirements for special installations or places Electric vehicle power supply; --- Part 7-740.Requirements for special installations or places, structures, entertainment facilities and sheds in playgrounds and circuses; --- Part 7-753.Requirements for special installations or places Heating cables and embedded heating systems. This document replaces GB/T 16895.13-2012 "Low-Voltage Electrical Installations Part 7-701.Requirements for Special Installations or Places" Locations for Bathtubs and Showers", compared with GB/T 16895.13-2012, except for structural adjustments and editorial changes, the main technical changes are as follows. --- Changed the scope (see 701.1, 701.1 of the.2012 edition); --- Added related terms and definitions (see 701.3); --- Changed the area description (see 701.30, 701.512, 701.30, 701.512 of the.2012 edition); --- Added equipment clauses for safety protection, isolation, switching, control and monitoring (see 701.53); --- Delete the ground heating system clause (see 701.753 of the.2012 edition). This document is equivalent to IEC 60364-7-701.2019 "Low Voltage Electrical Installations Part 7-701.Requirements for Special Installations or Locations" Locations with bathtubs or showers". The following editorial changes have been made to this document. ---Since Appendix A of IEC 60364-7-701.2019 is related to the application of this document by other countries, it has nothing to do with my country. In this deleted from the file. Please note that some contents of this document may refer to patents. The issuing agency of this document assumes no responsibility for identifying patents. This document is proposed and managed by the National Building Electrical Installation Standardization Technical Committee (SAC/TC205). This document is drafted by. China Machinery and Electronics Design and Research Institute Co., Ltd., Beijing Xingdian International Engineering Management Co., Ltd. The main drafters of this document. Chen Tong, Wang Dianguang, Huang Baosheng, Hou Yubinyu, Zhang Tieming. The release status of previous versions of this document and the documents it replaces are as follows. ---First published as GB 16895.13-2002 in.2002; ---The first revision in.2012 was GB/T 16895.13-2012; --- This is the second revision.

Introduction

GB/T 16895 (all parts) Safety protection of low-voltage electrical installations, selection, installation and inspection of electrical equipment, and special equipment The safety requirements of the location or place play a guiding role. GB/T 16895 is proposed to consist of six parts. --- Part 1.Basic principles, general characteristics assessment and definition. The purpose is to design, install and inspect low-voltage electrical installations Establish safety rules to avoid possible dangers to persons, domestic animals and property caused by low-voltage electrical installations in reasonable use and damage, and ensure the normal operation of electrical installations. --- Part 4.Safety protection. The purpose is to establish the protection against electric shock, thermal effect, overcurrent and voltage of low-voltage electrical installations. Basic requirements for protection against harassment and electromagnetic disturbance. --- Part 5.Selection and installation of electrical equipment. The purpose is based on the basic requirements of safety protection, to establish the Functional requirements for long-term use and general rules suitable for external influence requirements, as well as establishment of wiring systems, isolation, switching and control Electrical equipment, grounding configurations and protective conductors, low-voltage power generation equipment and auxiliary equipment, safety facilities and their power supply systems, etc. Equipment selection and installation requirements. --- Part 6.Inspection. The purpose is to establish requirements for preliminary and periodic inspections of electrical installations. --- Part 8.Functional aspects. The purpose is to propose a proposal for the evaluation of energy efficiency (EE) in the design, installation and operation of electrical installations. requirements, recommendations and methods. The above-mentioned Parts 1, 4, 5 and 6 are general requirements and regulations (general parts), and generally apply to Used in Part 7 (undated reference), but in special installations and places, Part 7 proposes to supplement, modify or replace GB/T 16895 Some provisions and requirements of Part 1, Part 4, Part 5 and Part 6. The special requirements of this document are to supplement, modify or replace some of the general parts of GB/T 16895 that are still valid when this document is published. some requirements. If there is no reference to a chapter, clause or clause excluding the general part, it means that the corresponding clause of the general part still applies (undated period reference). or replace certain requirements in effect at the time of publication. The numbering of the clauses of this document follows the pattern of GB/T 16895 and shall be referenced accordingly. The numbers following 701 are all The numbers of chapters, articles or clauses of the corresponding parts of GB/T 16895 indicate normative references to these documents (date references). If additional requirements or explanations are required for other parts of the GB/T 16895 series, 701.101, 701.102, 701.103 et al. No. If, after the publication of this document, a new or revised general part is issued with a change number, the general part referenced in this document The clause number of the subsection may no longer be consistent with the latest version of the general part, and should be cited with a date. Low-voltage electrical installations Part 7-701.Special installations or place requirements for places with tubs or showers 701 Establishments with bathtubs or showers 701.1 Scope The special requirements of this document apply to indoor or outdoor electrical installations with bathtubs and/or showers, where the bathtubs and/or The shower is intended to be permanently installed in a specific location. The scope of places equipped with bathtubs and/or showers is. --- The lowest ground finish surface; --- 3m horizontal plane above the lowest ground finish surface; --- a vertical surrounding virtual surface at a distance of 4 m from the fixed outlet of the tub or shower; and --- Adjacent to the wall, floor and ceiling of the place where the bathtub or shower is installed, the minimum thickness of the entity is 6cm. Note 1.When the shower head and hose are movable, the fixed water outlet is located at the water supply end of the hose. The requirements of this document also apply to fixed electrical installations in mobile installations, such as caravans, motorhomes, shower enclosures. This document does not apply to Emergency facilities, such as emergency showers for use in industrial areas or laboratories. Note 2.For places with tubs or showers used for medical treatment, special requirements may be required. Note 3.For prefabricated tubs and/or shower units, see IEC 60335-2-105. 701.2 Normative references The contents of the following documents constitute the essential provisions of this document through normative references in the text. Among them, dated references For documents, only the version corresponding to the date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to this document. GB/T 16895.21-2020 Low-voltage electrical installations Part 4-41.Safety protection Electric shock protection (IEC 60364-4-41. 2017, IDT) 701.3 Terms and Definitions The following terms and definitions apply to this document. The terminology databases maintained by ISO and IEC for standardization can be found at the following URLs. 701.3.1 place location specific place or location. Examples. dedicated rooms, an area of a room (eg attic), outdoor areas. 701.3.2 bathtub bathtub All or most of the human body can be submerged in water, and the water must be drained after each use.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 16895.13-2022_English be delivered?

Answer: Upon your order, we will start to translate GB/T 16895.13-2022_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 16895.13-2022_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 16895.13-2022_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 16895.13-2022?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 16895.13-2022 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.