HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

GB/T 16582-2008 English PDF

US$154.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 16582-2008: Plastics -- Determination of melting behaviour (melting temperature or melting range) of semi-crystalline polymers by capillary tube and polarizing-microscope methods
Status: Valid

GB/T 16582: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 16582-2008English154 Add to Cart 3 days [Need to translate] Plastics -- Determination of melting behaviour (melting temperature or melting range) of semi-crystalline polymers by capillary tube and polarizing-microscope methods Valid GB/T 16582-2008
GB/T 16582-1996English319 Add to Cart 3 days [Need to translate] Determination of melting point of semi-crystalline polymers--Capillary tube method Obsolete GB/T 16582-1996

PDF similar to GB/T 16582-2008


Standard similar to GB/T 16582-2008

GB/T 16422.4   GB/T 16422.3   GB/T 16578.2   GB/T 12008.7   

Basic data

Standard ID GB/T 16582-2008 (GB/T16582-2008)
Description (Translated English) Plastics -- Determination of melting behaviour (melting temperature or melting range) of semi-crystalline polymers by capillary tube and polarizing-microscope methods
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard G31
Classification of International Standard 83.080.01
Word Count Estimation 8,837
Date of Issue 2008-08-04
Date of Implementation 2009-04-01
Older Standard (superseded by this standard) GB/T 16582-1996; GB/T 4608-1984
Quoted Standard GB/T 2918-1998
Adopted Standard ISO 3146-2000, IDT
Regulation (derived from) National Standard Approval Announcement 2008 No.14 (Total No.127)
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the method for determining the melting behavior of partially crystalline polymers by capillary tube and polarizing microscopy. Method A (capillary method > for all crystalline polymers and blends thereof with method B (polarization microscopy) suitable polymeric birefringent crystalline phase, because the polymer will affect the birefringent crystalline regions, the does not apply to contain pigments and/or additives compounding fill material.

GB/T 16582-2008: Plastics -- Determination of melting behaviour (melting temperature or melting range) of semi-crystalline polymers by capillary tube and polarizing-microscope methods


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Plastics. Determination of melting behaviour (melting temperature or melting range) of semi-crystalline polymers by capillary tube and polarizing-microscope methods ICS 83.080.01 G31 National Standards of People's Republic of China GB/T 16582-2008/ISO 3146.2000 Replacing GB/T 16582-1996, GB/T 4608-1984 Plastic by Capillary and polarizing microscopy Partially crystalline polymer melting behavior (Melting temperature or melting range) (ISO 3146.2000, IDT) Posted 2008-08-04 2009-04-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

This standard is identical with ISO 3146.2000 "Plastics --- measured by capillary microscopy and polarizing partially crystalline polymer melt Behavior (melting temperature or melting range) "(in English). For ease of use, this standard made the following editorial changes. a) to the "international standards" be replaced by "this standard"; b) Delete the ISO 3146.2000 Foreword; c) increase the national standard foreword; d) the "Normative references" international standards with the corresponding equivalents listed in a chapter using this file in place of national standards; e) use of decimal notation. "" instead of the international standard decimal symbol "." This standard replaces GB/T 16582-1996 "partially crystalline polymer melting point Capillary tube method" and GB/T 4608-1984 "Standard Test Method for partially crystalline melting point of the polymer optical method", the GB/T 16582-1996, GB/T 4608-1984 combined, were party Method A and Method B. The standard methods A and GB/T 16582-1996 differences are as follows. --- Increasing the normative references (Chapter 2); --- Thermometer. scale value 1 ℃ to scale value 0.1 ℃ (4.2.3); --- Original standard sample loading height. powder sample, sample loading height of about 5mm ~ 10mm, the standard does not provide now. The standard methods B and GB/T 4608-1984 differences are as follows. --- Original standard thermometer division is 1 ℃, no division is now standard predetermined value; --- Powder sample size and sample size. from 1mg ~ 2mg to 2mg ~ 3mg, powder particle size not exceeding 100μm kind of (5.3.1); --- Thickness of the film formed by heating a sample. from below 0.05mm to 0.01mm ~ 0.04mm (5.3.1); --- Increase mold and plastic pellet sample (5.3.2); --- Increased conditioning (5.3.4); --- Increased precision (5.5). The standard proposed by China Petroleum and Chemical Industry Association. This standard by the National Standardization Technical Committee of plastic (SAC/TC15) centralized. This standard is drafted by. National Quality Supervision and Inspection Center of synthetic resin, Hangzhou Normal University. Participated in the drafting of this standard. National Plastic Products Quality Inspection Center (Beijing), Sinopec hospital north of the National Chemical Building Materials Testing Center (Materials Testing Division), blond Technology Co., Ltd. Drafters of this standard. Bo Yun Ling, Qiu Yu, Ning Zheng, Jiaqi, Xuxiang Qing, Liu Qixiang. This standard replaces the standards previously issued as follows. --- GB/T 4608-1984; --- GB/T 16582-1996. GB/T 16582-2008/ISO 3146.2000 Plastic by Capillary and polarizing microscopy Partially crystalline polymer melting behavior (Melting temperature or melting range)

1 Scope

This standard specifies the method of melting behavior of crystalline polymers by Capillary and polarizing microscopy method. Method A (capillary method) is applicable to all crystalline polymers and their compounding matter. Method B (polarized light microscopy) applicable to the birefringent crystalline phase of the polymer. Because birefringence effects of polymer crystalline regions, the Does not apply to contain pigments and/or filled with a blend of additives. Note 1. A method can also evaluate the softening temperature of the non-crystalline solid. Note 2. The melting temperature measured by different methods usually a few degrees (K) difference. Note 3. Another method GB/T 19466.3-2004 "plastic differential scanning calorimetry (DSC) - Part 3. melting and crystallization temperature and enthalpy Determination, "also applies to the determination of crystalline polymers melting behavior.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 2918-1998 standard plastic sample conditioning and environmental tests (idt ISO 291.1997)

3 Terms and Definitions

The following terms and definitions apply to this standard. 3.1 Crystalline phase and amorphous phase-containing polymer. 3.2 When heated, the crystalline or partly crystalline polymer crystallization characteristics or shape disappearance temperature range. 4 Method A --- capillary method 4.1 Principle The sample was heated at a controlled rate, measuring the temperature began to significantly change the shape and the crystal phase completely disappeared. Temperature changes shape as the melting temperature of the sample, the temperature range between the two, is the melting range. Note. according to the standard or the parties concerned about the consultation, the present method can also be used for non-crystalline material. 4.2 the device (see Figure 1) 4.2.1 melting equipment consists of the following components. a) a cylindrical metal block, the upper part is hollow and forms a small cavity. b) a metal plug, with two or more holes, allowing a thermometer and a piece of metal or a plurality of capillaries loaded. c) means for heating the metal block of the system, e.g., encapsulated in a metal block resistance wire. d) if the use of electric heating, should regulate power input varistor box. GB/T 16582-2008/ISO 3146.2000

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 16582-2008_English be delivered?

Answer: Upon your order, we will start to translate GB/T 16582-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 16582-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 16582-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 16582-2008?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 16582-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.