HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

GB/T 15721.1-2009 English PDF

US$174.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 15721.1-2009: Prosthetics and orthotics -- Limb deficiencies -- Part 1: Method of describing limb deficiencies present at birth
Status: Valid

GB/T 15721.1: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 15721.1-2009English174 Add to Cart 3 days [Need to translate] Prosthetics and orthotics -- Limb deficiencies -- Part 1: Method of describing limb deficiencies present at birth Valid GB/T 15721.1-2009
GB/T 15721.1-1995English439 Add to Cart 3 days [Need to translate] Prosthetics and orthotics--Limb deficiencies. Part 1: Method of describing limb deficiencies present at birth Obsolete GB/T 15721.1-1995

PDF similar to GB/T 15721.1-2009


Standard similar to GB/T 15721.1-2009

WS/T 655   GB/T 36388   WS/T 367   GB/T 15721.3   GB/T 15721.2   GB/T 15721.5   

Basic data

Standard ID GB/T 15721.1-2009 (GB/T15721.1-2009)
Description (Translated English) Prosthetics and orthotics -- Limb deficiencies -- Part 1: Method of describing limb deficiencies present at birth
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard C05
Classification of International Standard 11.180
Word Count Estimation 9,926
Date of Issue 2009-09-30
Date of Implementation 2009-12-01
Older Standard (superseded by this standard) GB/T 15721.1-1995
Quoted Standard GB/T 14191.1; ISO 8549-2-1989
Adopted Standard ISO 8548-1-1989, IDT
Regulation (derived from) National Standard Approval Announcement 2009 No.10 (Total No.150)
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the congenital upper limb, Method of describing lower limb missing. This standard applies described by means of anatomy and radiology presented, because the limb skeletal dysplasia of bone loss, without involving the etiology, Inso infectious diseases.

GB/T 15721.1-2009: Prosthetics and orthotics -- Limb deficiencies -- Part 1: Method of describing limb deficiencies present at birth


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Prosthetics and orthotics Limb deficiencies Part 1. Method of describing limb deficiencies present at birth ICS 11.180 C05 National Standards of People's Republic of China GB/T 15721.1-2009/ISO 8548-1. 1989 Replacing GB/T 15721.1-1995 Prosthetics and orthotics - Limb deficiencies Part 1. congenital limb deficiencies Description Method (ISO 8548-1. 1989, IDT) Posted 2009-09-30 2009-12-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

GB/T 15721 "Prosthetics and orthotics - Limb deficiencies" is divided into five parts. --- Part 1. congenital limb deficiencies described method; --- Part 2. Method of describing lower limb amputation stumps; --- Part 3. Method of describing upper limb amputation stumps; --- Part 4. Description amputation reasons; --- Part 5. description of the clinical symptoms of amputees. This section GB/T 15721 Part 1. This section identical with ISO 8548-1. 1989 "Prosthetics and orthotics - Limb deficiencies - Part 1. congenital limb deficiencies Description Method "(in English). For ease of use, this section made the following editorial changes. a) Remove the preface to the international standards; b) "this International Standard" by "this section." This Part replaces GB/T 15721.1-1995 "Prosthetics and orthotics - Limb deficiencies - Part 1. congenital limb deficiencies Description Method. " Section compared with the GB/T 15721.1-1995, major changes in the following. a) the normative references, the references GB/T 14191.1 "Prosthetics and orthotics academic language - Part 1. In vitro false limbs In vitro and limb orthotics basic terminology "(GB/T 14191.1-2009, ISO 8549-1. 1989, IDT); b) the scope of the standard, the words "This standard applies to anatomy and radiology described by means of the presentation of the" skeleton Missing. Appendix A of this section is an informative annex. This section proposed by the People's Republic of China Ministry of Civil Affairs. This part of the National Rehabilitation and special equipment Standardization Technical Committee on Persons with Disabilities (SAC/TC148) centralized. This section drafted by. China Rehabilitation Devices Association, China Rehabilitation Research Center, the National Research Center for Rehabilitation Technical Aids. The main drafters of this section. Yangcheng Rui, Ding Botan, Liu Qi. This part of the standard replaces the previous editions are. --- GB/T 15721.1-1995. GB/T 15721.1-2009/ISO 8548-1. 1989

Introduction

There have been many kinds of amputation stump to the classification of methods, but none of the generally accepted method in which a variety of reasons. Small clinical Group members in different countries, different patients, which can only study different methods to suit their needs. Hence the need for an international To compare the works of different, different from patient to patient's general approach. A variety of medical staff, including surgeons received training in different (especially Notably those related to rehabilitation), physical therapists and occupational therapists and prosthetists, accept and use a descriptive standard stump party law. This method epidemic experts and government officials responsible for health equally valuable. Methods have been developed should meet the needs of different members of the treatment team, and be able to describe the stumps for ease reflected in the records of the party Type record, this part of GB/T 15721 is intended to define the minimum information described, this information should have taken the computer analysis Carolina capacity. GB/T 15721.1-2009/ISO 8548-1. 1989 Prosthetics and orthotics - Limb deficiencies Part 1. congenital limb deficiencies Description Method

1 Scope

This section GB/T 15721 specifies the congenital upper limb, lower limb deficiencies present description method. This standard applies to anatomy and radiology described by means of the presentation of the due limb skeletal dysplasia of bone is missing; without Factors that cause infectious diseases relates.

2 Normative references

The following documents contain provisions which, through reference GB/T 15721 in this section constitute provisions of this section. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section. GB/T 14191.1 Prosthetics and orthotics academic language - Part 1. Basic terminology external limb prostheses and external orthoses (GB/T 14191.1-2009, ISO 8549-1. 1989, IDT) ISO 8549-2. 1989 Prosthetics and orthotics academic language - Part 2. With external limb prostheses and prosthetic users such relevant the term

3 Terms and Definitions

GB/T 14191.1, ISO 8549-2. 1989 terms and definitions established in this section apply to GB/T 15721 of.

4 Missing description

4.1 Overview First to "Landscape" or "Portrait" describes missing, and further in various forms 4.2 and 4.3 of the description noted. When a patient is missing more than When a limb, should be described separately. 4.2 lateral Missing Press the following description of the missing transverse. a) other side (left or right); b) limb (arm or leg); c) the degree, according to Figure 1. GB/T 15721.1-2009/ISO 8548-1. 1989

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 15721.1-2009_English be delivered?

Answer: Upon your order, we will start to translate GB/T 15721.1-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 15721.1-2009_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 15721.1-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 15721.1-2009?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 15721.1-2009 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.