HOME   Cart(1)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

GB/T 15261-2008 English PDF

US$329.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 15261-2008: Measurement methods for acoustic properties of ultrasonically tissue-mimicking materials
Status: Valid

GB/T 15261: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 15261-2008English329 Add to Cart 3 days [Need to translate] Measurement methods for acoustic properties of ultrasonically tissue-mimicking materials Valid GB/T 15261-2008
GB/T 15261-1994English239 Add to Cart 2 days [Need to translate] Methods of measuring the acoustic characteristics of ultrasonically tissue-mimicking materials Obsolete GB/T 15261-1994

PDF similar to GB/T 15261-2008


Standard similar to GB/T 15261-2008

GB 9706.237   GB 9706.4   GB 10152   GB/T 12257   GB/T 11748   

Basic data

Standard ID GB/T 15261-2008 (GB/T15261-2008)
Description (Translated English) Measurement methods for acoustic properties of ultrasonically tissue-mimicking materials
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard C41
Classification of International Standard 17.140.50
Word Count Estimation 14,157
Date of Issue 2008-01-22
Date of Implementation 2008-09-01
Older Standard (superseded by this standard) GB/T 15261-1994
Quoted Standard GB 3101.7-1993; GB/T 3947-1996; GB/T 4472-1984; YY/T 0458-2003
Regulation (derived from) National Standard Approval Announcement 2008 No.2 (Total No.115)
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the method for measuring the acoustic characteristics of ultrasonic imitation tissue material parameters. This standard applies to ultrasound tissue material density and sound velocity imitation within 1MHz ~ 10MHz frequency range, measuring acoustic attenuation coefficient and backscatter coefficient, mainly for the production of such material ultrasound phantom.

GB/T 15261-2008: Measurement methods for acoustic properties of ultrasonically tissue-mimicking materials


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Measurement methods for acoustic properties of ultrasonically tissue-mimicking materials ICS 17.140.50 C41 National Standards of People's Republic of China Replacing GB/T 15261-1994 Methods of measurement of ultrasonic acoustic properties of tissue mimicking material Posted 2008-01-22 2008-09-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

This standard replaces GB/T 15261-1994 "ultrasonic measurement of human tissue material acoustic characteristics of imitation." Compared with the standard GB/T 15261-1994 The main changes are as follows. --- Standard English name more standardized; --- Sample for measurement equipment and technical requirements more rigorous and detailed presentation; --- Consistent with international practice, the standard temperature measurement conditions employed from 25 ℃ to 23 ℃; --- Density measurements instead GB/T 4472-1984 buoyancy and the flask method; --- Measuring sound attenuation coefficient cancel single sample method, only to double sample method; --- Correlation processing sound attenuation coefficient versus frequency by general linear fitting to fitting a straight line through the origin of coordinates and curve fitting Two kinds; --- Increased backscatter coefficient measurement of content; --- Measuring the speed of sound and attenuation coefficient increases uncertainty analysis section; --- Appendix increases the density of water, sound speed and attenuation coefficient versus temperature of the contents; --- An increase in the reference section. The Standard Appendix A, Appendix B, Appendix C, Appendix D, Appendix E are informative appendices. This standard was proposed by the State Food and Drug Administration. This standard by the National Standardization Technical Committee medical appliances (SAC/TC10) centralized. This standard was drafted. Institute of Acoustics. The main drafters of this standard. Cattle Fengqi, Zhu Chenggang, Cheng Yang. This standard was first published in 1994. Methods of measurement of ultrasonic acoustic properties of tissue mimicking material

1 Scope

This standard specifies the method for measuring the acoustic characteristics of ultrasound tissue mimicking material parameters. This standard applies to ultrasound tissue mimicking material density and sound velocity, attenuation coefficient and sound back in the frequency range of 1MHz ~ 10MHz Measuring the scattering coefficient, mainly for the production of such materials ultrasound phantom.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB 3102.7-1993 Quantities and units of acoustics GB/T 3947-1996 Acoustics Terminology GB/T 4472-1984 Chemical density, relative density measurement General YY/T 0458-2003 simulated Doppler blood flow phantom technical requirements (IEC 61685.2001, MOD)

3 Terms and Definitions

GB/T 3947-1996 and established in the following terms and definitions apply to this standard. 3.1 Mimic human soft tissue material in the ultrasonic wave propagation characteristics, referred to as TM material. 3.2 Some imitate ultrasound propagation characteristics of the human body, for to do performance measurement and research testing in medical ultrasound equipment, or simulated physiological structure Visualization passive devices. 3.3 Sound attenuation coefficient rate of change with frequency. Unit. dB per centimeter MHz, dB/(cm · MHz). 3.4 On the incident sound waves into a 180 ° angle to the per unit volume and unit solid angle of the differential scattering cross section. Unit. steradian per centimeter, cm-1 · sr-1.

4 measuring principle

4.1 density measurement 4.1.1 Overview Press morphological classification, ultrasound tissue mimicking material may be a solid, liquid or gel, and the gel and have the overall dispersion of the points, so the density

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 15261-2008_English be delivered?

Answer: Upon your order, we will start to translate GB/T 15261-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 15261-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 15261-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 15261-2008?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 15261-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.