HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

GB/T 15076.9-2008 English PDF

US$169.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 15076.9-2008: Methods for chemical analysis of tantalum and niobium -- Determination of iron, chromium, nickel, manganese, titanium, aluminum, copper, tin, lead and zirconium contents in tantalum
Status: Valid

GB/T 15076.9: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 15076.9-2008English169 Add to Cart 3 days [Need to translate] Methods for chemical analysis of tantalum and niobium -- Determination of iron, chromium, nickel, manganese, titanium, aluminum, copper, tin, lead and zirconium contents in tantalum Valid GB/T 15076.9-2008
GB/T 15076.9-1994English199 Add to Cart 2 days [Need to translate] Methods for chemical analysis of tantalum and niobium-Determination of iron, chromium, nickel, manganese, titanium, aluminum, copper and zirconium contents in tantalum Obsolete GB/T 15076.9-1994

PDF similar to GB/T 15076.9-2008


Standard similar to GB/T 15076.9-2008

GB/T 14635   GB/T 15076.3   GB/T 15076.1   GB/T 15076.6   GB/T 15076.7   GB/T 15076.4   

Basic data

Standard ID GB/T 15076.9-2008 (GB/T15076.9-2008)
Description (Translated English) Methods for chemical analysis of tantalum and niobium -- Determination of iron, chromium, nickel, manganese, titanium, aluminum, copper, tin, lead and zirconium contents in tantalum
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard H14
Classification of International Standard 77.120.99
Word Count Estimation 7,780
Date of Issue 2008-03-31
Date of Implementation 2008-09-01
Older Standard (superseded by this standard) GB/T 15076.9-1994
Regulation (derived from) National Standard Approval Announcement 2008 No.5 (Total No.118)
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the tantalum iron, chromium, Nickel, manganese, determination of lead and zirconium content, titanium, aluminum, copper, tin. This section applies to tantalum oxide and iron, chromium, Nickel, determination of lead and zirconium content, manganese, titanium, aluminum, copper, tin.

GB/T 15076.9-2008: Methods for chemical analysis of tantalum and niobium -- Determination of iron, chromium, nickel, manganese, titanium, aluminum, copper, tin, lead and zirconium contents in tantalum



---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods for chemical analysis of tantalum and niobium. Determination of iron, chromium, nickel, manganese, titanium, aluminum, copper, tin, lead and zirconium contents in tantalum ICS 77.120.99 H14 National Standards of People's Republic of China Replacing GB/T 15076.9-1994 Methods for chemical analysis of tantalum and niobium and tantalum iron, chromium, nickel, manganese, Determination of titanium, aluminum, copper, tin, lead and zirconium quantity Posted 2008-03-31 2008-09-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

GB/T 15076 "Methods for chemical analysis of tantalum and niobium" is divided into 16 parts. --- GB/T 15076.1 Methods for chemical analysis of tantalum and niobium, tantalum and niobium - Determination of the amount of --- Determination of GB/T 15076.2 Methods for chemical analysis of tantalum and niobium and tantalum niobium content --- Determination of GB/T 15076.3 chemical analysis of tantalum and niobium copper content --- Determination of GB/T 15076.4 chemical analysis of tantalum and niobium iron content --- GB T 15076.5 Methods for chemical analysis of molybdenum, tantalum, niobium and tungsten contents - / Determination --- GB/T 15076.6 chemical analysis of tantalum and niobium and tantalum silicon content --- GB/T 15076.7 chemical analysis of tantalum and niobium and niobium determination of phosphorus content Determination --- GB/T 15076.8 Methods for chemical analysis of tantalum and niobium carbon and sulfur content --- Determination of GB/T 15076.9 chemical analysis of tantalum and niobium and tantalum iron, chromium, nickel, manganese, titanium, aluminum, copper, tin, lead and zirconium quantity --- Determination of GB/T 15076.10 chemical analysis of tantalum and niobium and niobium iron, nickel, chromium, titanium, zirconium, aluminum and manganese contents --- GB/T 15076.11 chemical analysis of tantalum and niobium and niobium arsenic, antimony, lead, tin and bismuth contents --- Determination of GB/T 15076.12 chemical analysis of tantalum and niobium and tantalum of phosphorus content Determination --- GB/T 15076.13 chemical analysis of tantalum and niobium tantalum nitrogen content --- Determination of GB/T 15076.14 chemical analysis of tantalum and niobium for oxygen Determination --- GB/T 15076.15 chemical analysis of tantalum and niobium amount of hydrogen --- Determination of GB/T 15076.16 Methods for chemical analysis of tantalum and niobium amount of sodium and potassium contents of Part is divided into 9 parts. This Part replaces measured GB/T 15076.9-1994 "Methods for chemical analysis of tantalum and niobium and tantalum iron, chromium, nickel, manganese, titanium, aluminum, copper and zirconium quantity set". This section compared with the GB/T 15076.9-1994, have the following main changes. --- Increase the determination of lead, tin content; --- Change the measurement range. measurement range iron from 0.00050% to 0.020% revised to 0.00030% - 0.040%; chromium, nickel It measured by the scope of 0.00020% ~ 0.010% revised to 0.00030% - 0.040%; measuring manganese range from 0.00010% ~ 0.010% revised to 0.00010% - 0.040%; titanium measuring range from 0.00020% to 0.010% ~ ~ modified to 0.00010% 0.040%; zirconium measurement range from 0.00010% ~ 0.0030% revised to 0.00010% - 0.040%; measurement range from aluminum 0.00010% ~ 0.0030% revised to 0.00010% to 0.020%; copper measuring range from 0.00005% ~ 0.0010% revised to 0.00010% to 0.020%; --- Complements the precision and quality assurance and control provisions; --- Text format has been re-edited. This part is proposed by the China Nonferrous Metals Industry Association. The non-ferrous metal part by the National Standardization Technical Committee. Ningxia Orient Tantalum Industry Co., Ltd. in this section by the China Nonferrous Metals Industry Institute of Standards Metrology and Quality is responsible for drafting. The main drafters of this section. Chenming Lun, Liu Chunyu, Liaoxing Lian, Su Yanping, Huo Hongfeng. This part of the standard replaces the previous editions are. --- GB/T 15076.9-1994. Methods for chemical analysis of tantalum and niobium Determination of iron, tantalum, chromium, nickel, manganese, titanium, aluminum, copper, tin, lead and zirconium quantity

1 Scope

This section provides tantalum iron, chromium, nickel, manganese, titanium, aluminum, copper, tin, lead, and determination of zirconium content. This section applies to the determination of tantalum and oxide of iron, chromium, nickel, manganese, titanium, aluminum, copper, tin, lead, and zirconium content. Determination of the range in Table 1. Table 1 Element measurement range /% Aluminum, copper 0.00010 0.020 Manganese, titanium, tin, lead, zirconium 0.00010 to 0.040 Iron, chromium, nickel 0.00030 to 0.040

2 Method summary

The tantalum metal and burning compound is converted to an oxide, with a certain proportion of carbon and sodium chloride mixture as carrier, DC arc anode Excitation spectral quantitatively.

3 Reagents and materials

Unless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled water or equivalent purity. 3.1 tantalum pentoxide. the tantalum powder (purity ≥99.99%) at 1000 ℃ burning made matrix stored separately. 3.2 ferric oxide. pure spectrum. 3.3 chromium oxide. pure spectrum. 3.4 nickel oxide. pure spectrum. 3.5 manganese tetroxide. pure spectrum. 3.6 Titanium dioxide. pure spectrum. 3.7 aluminum oxide. pure spectrum. 3.8 copper oxide. pure spectrum. 3.9 SNO. pure spectrum. 3.10 Lead dioxide. pure spectrum. Zirconium dioxide 3.11. pure spectrum. 3.12 germanium dioxide. pure spectrum. 3.13 Sodium chloride. pure class distinctions, at 500 ℃ burning 2h. 3.14 Palladium. purity of more than 99.95%. 3.15 graphite powder. pure spectrum. 3.17 vector preparation 3.17.1 The 0.250g palladium metal placed in a small beaker, add 40mL aqua regia, after the complete dissolution of palladium transferred to 100mL volumetric flask, to Dilute with water to volume, and mix the solution 1mL containing 2.5mg of palladium.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 15076.9-2008_English be delivered?

Answer: Upon your order, we will start to translate GB/T 15076.9-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 15076.9-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 15076.9-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 15076.9-2008?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 15076.9-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.