HOME   Cart(1)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

GB/T 15076.10-2019 English PDF

US$139.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 15076.10-2019: Methods for chemical analysis of tantalum and niobium -- Part 10: Determination of iron, nickel, chromium, titanium, zirconium, aluminum and manganese contents in niobium -- Direct current arc atomic emission spectrometry
Status: Valid

GB/T 15076.10: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 15076.10-2019English139 Add to Cart 3 days [Need to translate] Methods for chemical analysis of tantalum and niobium -- Part 10: Determination of iron, nickel, chromium, titanium, zirconium, aluminum and manganese contents in niobium -- Direct current arc atomic emission spectrometry Valid GB/T 15076.10-2019
GB/T 15076.10-1994English199 Add to Cart 2 days [Need to translate] Methods for chemical analysis of tantalum and niobium. Determination of iron, nickel, chromium, titanium, zirconium, aluminum and manganese contents in niobium Obsolete GB/T 15076.10-1994

PDF similar to GB/T 15076.10-2019


Standard similar to GB/T 15076.10-2019

GB/T 14635   GB/T 15076.3   GB/T 15076.1   GB/T 15076.6   GB/T 15076.7   GB/T 15076.4   

Basic data

Standard ID GB/T 15076.10-2019 (GB/T15076.10-2019)
Description (Translated English) Methods for chemical analysis of tantalum and niobium -- Part 10: Determination of iron, nickel, chromium, titanium, zirconium, aluminum and manganese contents in niobium -- Direct current arc atomic emission spectrometry
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard H14
Classification of International Standard 77.120.99
Word Count Estimation 7,758
Date of Issue 2019-12-31
Date of Implementation 2020-11-01
Issuing agency(ies) State Administration for Market Regulation, China National Standardization Administration

GB/T 15076.10-2019: Methods for chemical analysis of tantalum and niobium -- Part 10: Determination of iron, nickel, chromium, titanium, zirconium, aluminum and manganese contents in niobium -- Direct current arc atomic emission spectrometry



---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods for chemical analysis of tantalum and niobium-Part 10. Determination of iron, nickel, chromium, titanium, zirconium, aluminum and manganese contents in niobium-Direct current arc atomic emission spectrometry ICS 77.120.99 H14 National Standards of People's Republic of China Replaces GB/T 15076.10-1994 Chemical analysis of tantalum and niobium Part 10. Iron, nickel, chromium, titanium, zirconium, aluminum in niobium And determination of manganese content DC arc atomic emission spectrometry 2019-12-31 release 2020-11-01 implementation State Administration of Market Supervision Published by the National Standardization Administration

Foreword

GB/T 15076 "Chemical Analysis Methods for Tantalum and Niobium" is divided into 16 parts. --- Part 1. Determination of tantalum in niobium by inductively coupled plasma atomic emission spectrometry; --- Part 2. Determination of the amount of niobium in tantalum by inductively coupled plasma atomic emission spectrometry and chromatogravimetry; --- Part 3. Determination of copper content by flame atomic absorption spectrometry; --- Part 4. Determination of iron content 1,10-diazaphenanthrene spectrophotometry; --- Part 5. Determination of the amount of molybdenum and tungsten; inductively coupled plasma atomic emission spectrometry; --- Part 6. Determination of silicon content by inductively coupled plasma atomic emission spectrometry; --- Part 7. Determination of phosphorus content in niobium 4-methyl-pentanone- [2] Extraction and separation of phosphorus molybdenum blue spectrophotometry and inductively coupled plasma Bulk atomic emission spectroscopy; --- Part 8. Determination of carbon and sulfur content High-frequency combustion infrared absorption method; --- Part 9. Determination of iron, chromium, nickel, manganese, titanium, aluminum, copper, tin, lead and zirconium in tantalum by DC arc atomic emission spectrometry; --- Part 10. Determination of iron, nickel, chromium, titanium, zirconium, aluminum and manganese in niobium by DC arc atomic emission spectrometry; --- Part 11. Determination of arsenic, antimony, lead, tin and bismuth in niobium by DC arc atomic emission spectrometry; --- Part 12. Determination of phosphorus content in tantalum Phosphomolybdenum blue spectrophotometric method for extraction and separation of ethyl acetate; --- Part 13. Determination of nitrogen content; inert gas fusion thermal conductivity method; --- Part 14. Determination of oxygen content Inert gas fusion infrared absorption method; --- Part 15. Determination of hydrogen content; inert gas fusion thermal conductivity method; --- Part 16. Determination of sodium and potassium content by flame atomic absorption spectrometry. This part is Part 10 of GB/T 15076. This section is drafted in accordance with the rules given in GB/T 1.1-2009. This section replaces GB/T 15076.10-1994 "Methods for chemical analysis of tantalum and niobium. Determination of iron, nickel, chromium, titanium, zirconium, aluminum and manganese in niobium". Compared with GB/T 15076.10-1994, the main technical changes in this section are as follows. --- Changed the test method from "DC Arc Carrier Fractionation Atomic Emission Spectroscopy" to "DC Arc Atomic Emission Spectroscopy"; --- Expanded the measurement range, the measurement range of zirconium and manganese content was changed from "0.0001% ~ 0.010%" to "0.0001% ~ 0.030% "; the determination range of aluminum content was changed from" 0.0002% ~ 0.010% "to" 0.0002% ~ 0.030% "; The measurement range was changed from "0.0001% ~ 0.020%" to "0.0001% ~ 0.030%" (see Chapter 1, Section 1 of the.1994 edition) chapter); --- Removed the reference standard (see Chapter 2 of the.1994 edition); --- Added sample clauses (see Chapter 5); --- Added precision clause (see Chapter 8); --- Added test report clauses (see Chapter 9). This section is proposed by China Nonferrous Metals Industry Association. This section is under the jurisdiction of the National Nonferrous Metals Standardization Technical Committee (SAC/TC243). This section was drafted. Ningxia Dongfang Tantalum Co., Ltd., Northwest Rare Metal Materials Research Institute Ningxia Co., Ltd., Xi'an Han and Tang Dynasties Analysis and Testing Co., Ltd., Jiujiang Nonferrous Metal Smelting Co., Ltd., Northwest Nonferrous Metal Research Institute, National Standard (Beijing) Inspection and Certification Co., Ltd. The main drafters of this section. Zhang Junfeng, Xu Ninghui, Wang Zhiping, Zhang Renhui, Zhai Tongde, Wang Yubao, Wei Hongnan, Wang Changhua, Sun Hongtao, Zhou Yan. The previous versions of the standards replaced by this section are. --- GB/T 15076.10-1994. Chemical analysis of tantalum and niobium Part 10. Iron, nickel, chromium, titanium, zirconium, aluminum in niobium And determination of manganese content DC arc atomic emission spectrometry

1 Scope

This part of GB/T 15076 specifies the direct current arc atomic emission spectrometry for the determination of iron, nickel, chromium, titanium, zirconium, aluminum and manganese in niobium. This section applies to the determination of iron, nickel, chromium, titanium, zirconium, aluminum and manganese in niobium and niobium hydroxide, niobium oxide and niobium carbide. See measuring range Table 1. Table 1 Elements and determination ranges Element determination range /% Iron, nickel, chromium 0.0003 ~ 0.030 Titanium, zirconium, manganese 0.0001 ~ 0.030 Aluminum 0.0002 ~ 0.030

2 Principle

Burning metal niobium and its hydroxides and carbides into niobium pentoxide, mixing graphite powder and sodium fluoride in a certain proportion Granules, DC arc anode excitation, spectrometry.

3 Reagents or materials

3.1 Niobium pentoxide. wNb2O5≥99.99% (single content of other measured elements wx≤0.00001%), in a muffle furnace Burn for 2h, put in a desiccator and cool to room temperature, set aside. 3.2 Ferric trioxide (wFe2O3 ≥ 99.99%). 3.3 Nickel oxide (wNiO≥99.99%). 3.4 Chromium trioxide (wCr2O3 ≥ 99.99%). 3.5 Titanium dioxide (wTiO2≥99.99%). 3.6 Zirconium dioxide (wZrO2≥99.99%). 3.7 Aluminum oxide (wAl2O3≥99.99%). 3.8 Manganese dioxide (wMnO2≥99.99%). 3.9 Sodium fluoride. excellent grade pure. 3.10 graphite powder. spectrally pure. 3.11 Buffering agent. Weigh 9.40g of graphite powder (3.10), add 0.60g of sodium fluoride (3.9), and homogenize. 3.12 compression mold. made of plexiglass rod cart, the top is 2.9mm × 2mm.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 15076.10-2019_English be delivered?

Answer: Upon your order, we will start to translate GB/T 15076.10-2019_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 15076.10-2019_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 15076.10-2019_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 15076.10-2019?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 15076.10-2019 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.