HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

GB/T 14294-2008 English PDF

US$188.00 · In stock
Delivery: <= 1 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 14294-2008: Central-station air handling units
Status: Valid

GB/T 14294: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 14294-2008English188 Add to Cart 1 days [Need to translate] Central-station air handling units Valid GB/T 14294-2008
GB/T 14294-1993EnglishRFQ ASK 9 days [Need to translate] Central-station air handling units Obsolete GB/T 14294-1993

PDF similar to GB/T 14294-2008


Standard similar to GB/T 14294-2008

GB/T 39976   GB 50243   GB 50738   GB/T 29045   GB/T 14295   GB/T 14296   

Basic data

Standard ID GB/T 14294-2008 (GB/T14294-2008)
Description (Translated English) Central-station air handling units
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard P48
Classification of International Standard 23.120
Word Count Estimation 34,370
Date of Issue 2008-11-04
Date of Implementation 2009-06-01
Older Standard (superseded by this standard) GB 13326-1991; GB/T 14294-1993
Quoted Standard GB/T 1236-2000; GB/T 2624.3-2006; GB/T 9068-1988; GB/T 14296; GB/T 16803; JB/T 9064; JG/T 21-1999
Regulation (derived from) Announcement of Newly Approved National Standards No. 18 of 2008 (No. 131 overall)
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the Chinese Young Pioneers scarf worn by members of the requirements, test methods, inspection rules, packaging, storage and flags. This standard applies to textile fibers red scarf.

GB/T 14294-2008: Central-station air handling units

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Central-station air handling units ICS 23.120 P48 National Standards of People's Republic of China Replacing GB/T 14294-1993, GB 13326-1991 Modular air conditioning units Posted 2008-11-04 2009-06-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Preface Ⅰ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 Classification and mark 2 5 material 3 6 Requirement 3 Test Method 5 7 8 9 inspection rules 9 signs, packaging, transportation and storage 10 The basic contents of 10 product samples and instructions 10 Appendix A (normative) modular air conditioning units wind, air pressure and input power 12 Test Method Appendix B (normative) modular air conditioning units wind, air pressure and power input using field test method 17 Annex C (normative) modular air conditioning units leakage test method 20 Annex D (normative) modular air-conditioning unit casing deformation rate of 22 Test Method Appendix E (normative) combined cooling capacity of air conditioning units and heat supply 23 Test Method Annex F (informative) combined cooling capacity of air conditioning units and heat supply using field test 29

Foreword

This standard replaces GB/T 14294-1993 "modular air conditioning units" and GB 13326-1991 "noise air handling units Limit. " This standard and GB/T 14294-1993 and GB 13326-1991 main technical differences compared as follows. --- Performance Indicators. external static pressure when dry conditions is not less than 90% of the rated value; when wet condition rating of not less than 85%; and cooling capacity Rated heat input of not less than 95%; and increase the housing deformation rate and quantity of water resistance requirements. --- Unit noise is determined by the amount of wind and fully hydrostatic unit. --- Test Method for Change. the amount of cooling and heating load test, in addition to loop duct air enthalpy method, increase the room air enthalpy method; unit Leakage rate increased negative pressure means; the unit amount of wind pressure tests using the clear duct pitot tube and multi-air flow nozzle method; increase housing Deformation test points positive and negative pressure test. The Standard Appendix A, Appendix B, Appendix C, Appendix D, Appendix E is a normative appendix, Appendix F for the informative appendix. The standard proposed by the Ministry of Housing and Urban-Rural Development of the People's Republic of China. This standard by the National HVAC and purification equipment Standardization Technical Committee. This standard is drafted by. China Academy of Building Research. Participated in the drafting of this standard. Shanghai Sinko Air Conditioning Equipment Co., Ltd., Shanghai Yileng Air Conditioning Equipment Co., Ltd.-Hui air conditioning Equipment Factory, Panasonic Ecology Systems Guangdong Co., Ltd. Beijing Branch, artificial environment Tongfang Co., Ltd. Nanjing days plus air-conditioning Co., Ltd. (Tianjin factory), air conditioning Fengshen Jiangsu Group Co., Ltd., Zhejiang shield the artificial environment Equipment Co., Ltd., located in Guangdong Shenling Preparation Co., Texas Pacific Group Co., Ltd., Shenzhen McQuay Air Conditioning Co., Ltd. Kunshan Taiwan Electrical and Mechanical Services Ltd. Jia Chongqing beauty through With Refrigeration Equipment Co., Ltd. Shandong Europe Kai air conditioning. The main drafters of this standard. Zouyue Qin, Dai Lisheng, money splendor, then Zheng Lin, Zhao Liang, Wang Qingping, official Jinsheng, Lu Hui, Wei Du Li, Zhang school, Zhang Yong, Cuiyong Guo Zhang Qi buckle, Zheng Yongqing, Geng Kai. This standard replaces the standards previously issued as follows. --- GB/T 14294-1993. --- GB 13326-1991. Modular air conditioning units

1 Scope

This standard specifies the air handling units (referred to as the unit) terms and definitions, classification and marking, materials, requirements, test methods, inspection Rules, marking, packaging, transportation and storage, and other elements of product samples and specification. This standard applies to the functional segment is a combination unit that can complete air transport, mixing, heating, cooling, dehumidification, humidification, filtration, noise reduction, Heat recovery unit one or several processing functions. Refrigerant to the brine, ethylene glycol and direct expansion coil and electric heaters units, reference may be used. This standard does not apply to own cold, heat, air conditioner (filter), fan coil units, heaters and the like.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 1236-2000 Industrial fans using standardized airways performance test GB/T 2624.3-2006 with the differential pressure measuring device mounted to round pipe full pipe fluid flow - Part 3. Nozzle Venturi nozzle GB/T 9068-1988 Determination of heating, ventilation and air conditioning equipment noise sound power levels - Engineering method GB/T 14296 Air coolers and air heaters GB/T 16803 heating, ventilation, air conditioning, cleaning terminology JB/T 9064 coil pressure test and seal inspection JG/T 21-1999 air cooler and air heater performance test method

3 Terms and Definitions

GB/T 16803 and determined the following terms and definitions apply to this standard. 3.1 Assembled from a variety of air-handling functional segments made of an air handling equipment. Suitable for resistance greater than or equal 100Pa air-conditioning system. 3.2 Having one or more air handling unit body. Functional segment units are. air mixing, average current, filtered, cooled, primary and secondary heating, dehumidification, humidification, air blower, return fan, water, consumer Sound, heat recovery unit body. 3.3 In the standard state of air, the air volume flow per unit time through unit, in units of m3/h or m3/s. 3.4 Unit overcome their resistance at rated air flow, the static pressure difference between the air inlet and outlet unit, the unit is Pa.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 14294-2008_English be delivered?

Answer: Upon your order, we will start to translate GB/T 14294-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically in 24 hours. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 14294-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 14294-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 14294-2008?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 14294-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.