US$188.00 · In stock Delivery: <= 1 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 14294-2008: Central-station air handling units Status: Valid GB/T 14294: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 14294-2008 | English | 188 |
Add to Cart
|
1 days [Need to translate]
|
Central-station air handling units
| Valid |
GB/T 14294-2008
|
GB/T 14294-1993 | English | RFQ |
ASK
|
9 days [Need to translate]
|
Central-station air handling units
| Obsolete |
GB/T 14294-1993
|
PDF similar to GB/T 14294-2008
Basic data Standard ID | GB/T 14294-2008 (GB/T14294-2008) | Description (Translated English) | Central-station air handling units | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | P48 | Classification of International Standard | 23.120 | Word Count Estimation | 34,370 | Date of Issue | 2008-11-04 | Date of Implementation | 2009-06-01 | Older Standard (superseded by this standard) | GB 13326-1991; GB/T 14294-1993 | Quoted Standard | GB/T 1236-2000; GB/T 2624.3-2006; GB/T 9068-1988; GB/T 14296; GB/T 16803; JB/T 9064; JG/T 21-1999 | Regulation (derived from) | Announcement of Newly Approved National Standards No. 18 of 2008 (No. 131 overall) | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | Summary | This standard specifies the Chinese Young Pioneers scarf worn by members of the requirements, test methods, inspection rules, packaging, storage and flags. This standard applies to textile fibers red scarf. |
GB/T 14294-2008: Central-station air handling units---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Central-station air handling units
ICS 23.120
P48
National Standards of People's Republic of China
Replacing GB/T 14294-1993, GB 13326-1991
Modular air conditioning units
Posted 2008-11-04
2009-06-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
1 Scope 1
2 Normative references 1
3 Terms and definitions
4 Classification and mark 2
5 material 3
6 Requirement 3
Test Method 5 7
8 9 inspection rules
9 signs, packaging, transportation and storage 10
The basic contents of 10 product samples and instructions 10
Appendix A (normative) modular air conditioning units wind, air pressure and input power 12 Test Method
Appendix B (normative) modular air conditioning units wind, air pressure and power input using field test method 17
Annex C (normative) modular air conditioning units leakage test method 20
Annex D (normative) modular air-conditioning unit casing deformation rate of 22 Test Method
Appendix E (normative) combined cooling capacity of air conditioning units and heat supply 23 Test Method
Annex F (informative) combined cooling capacity of air conditioning units and heat supply using field test 29
Foreword
This standard replaces GB/T 14294-1993 "modular air conditioning units" and GB 13326-1991 "noise air handling units
Limit. "
This standard and GB/T 14294-1993 and GB 13326-1991 main technical differences compared as follows.
--- Performance Indicators. external static pressure when dry conditions is not less than 90% of the rated value; when wet condition rating of not less than 85%; and cooling capacity
Rated heat input of not less than 95%; and increase the housing deformation rate and quantity of water resistance requirements.
--- Unit noise is determined by the amount of wind and fully hydrostatic unit.
--- Test Method for Change. the amount of cooling and heating load test, in addition to loop duct air enthalpy method, increase the room air enthalpy method; unit
Leakage rate increased negative pressure means; the unit amount of wind pressure tests using the clear duct pitot tube and multi-air flow nozzle method; increase housing
Deformation test points positive and negative pressure test.
The Standard Appendix A, Appendix B, Appendix C, Appendix D, Appendix E is a normative appendix, Appendix F for the informative appendix.
The standard proposed by the Ministry of Housing and Urban-Rural Development of the People's Republic of China.
This standard by the National HVAC and purification equipment Standardization Technical Committee.
This standard is drafted by. China Academy of Building Research.
Participated in the drafting of this standard. Shanghai Sinko Air Conditioning Equipment Co., Ltd., Shanghai Yileng Air Conditioning Equipment Co., Ltd.-Hui air conditioning
Equipment Factory, Panasonic Ecology Systems Guangdong Co., Ltd. Beijing Branch, artificial environment Tongfang Co., Ltd. Nanjing days plus air-conditioning Co., Ltd.
(Tianjin factory), air conditioning Fengshen Jiangsu Group Co., Ltd., Zhejiang shield the artificial environment Equipment Co., Ltd., located in Guangdong Shenling
Preparation Co., Texas Pacific Group Co., Ltd., Shenzhen McQuay Air Conditioning Co., Ltd. Kunshan Taiwan Electrical and Mechanical Services Ltd. Jia Chongqing beauty through
With Refrigeration Equipment Co., Ltd. Shandong Europe Kai air conditioning.
The main drafters of this standard. Zouyue Qin, Dai Lisheng, money splendor, then Zheng Lin, Zhao Liang, Wang Qingping, official Jinsheng, Lu Hui, Wei Du Li, Zhang school,
Zhang Yong, Cuiyong Guo Zhang Qi buckle, Zheng Yongqing, Geng Kai.
This standard replaces the standards previously issued as follows.
--- GB/T 14294-1993.
--- GB 13326-1991.
Modular air conditioning units
1 Scope
This standard specifies the air handling units (referred to as the unit) terms and definitions, classification and marking, materials, requirements, test methods, inspection
Rules, marking, packaging, transportation and storage, and other elements of product samples and specification.
This standard applies to the functional segment is a combination unit that can complete air transport, mixing, heating, cooling, dehumidification, humidification, filtration, noise reduction,
Heat recovery unit one or several processing functions.
Refrigerant to the brine, ethylene glycol and direct expansion coil and electric heaters units, reference may be used.
This standard does not apply to own cold, heat, air conditioner (filter), fan coil units, heaters and the like.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 1236-2000 Industrial fans using standardized airways performance test
GB/T 2624.3-2006 with the differential pressure measuring device mounted to round pipe full pipe fluid flow - Part 3. Nozzle
Venturi nozzle
GB/T 9068-1988 Determination of heating, ventilation and air conditioning equipment noise sound power levels - Engineering method
GB/T 14296 Air coolers and air heaters
GB/T 16803 heating, ventilation, air conditioning, cleaning terminology
JB/T 9064 coil pressure test and seal inspection
JG/T 21-1999 air cooler and air heater performance test method
3 Terms and Definitions
GB/T 16803 and determined the following terms and definitions apply to this standard.
3.1
Assembled from a variety of air-handling functional segments made of an air handling equipment. Suitable for resistance greater than or equal 100Pa air-conditioning system.
3.2
Having one or more air handling unit body.
Functional segment units are. air mixing, average current, filtered, cooled, primary and secondary heating, dehumidification, humidification, air blower, return fan, water, consumer
Sound, heat recovery unit body.
3.3
In the standard state of air, the air volume flow per unit time through unit, in units of m3/h or m3/s.
3.4
Unit overcome their resistance at rated air flow, the static pressure difference between the air inlet and outlet unit, the unit is Pa.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 14294-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 14294-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically in 24 hours. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 14294-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 14294-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 14294-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 14294-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|