US$594.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 14055.2-2012: Reference neutron radiations -- Part 2: Calibration fundamentals of radiation protection devices related to the basic quantities characterizing the radiation field Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 14055.2-2012 | English | 594 |
Add to Cart
|
3 days [Need to translate]
|
Reference neutron radiations -- Part 2: Calibration fundamentals of radiation protection devices related to the basic quantities characterizing the radiation field
| Valid |
GB/T 14055.2-2012
|
PDF similar to GB/T 14055.2-2012
Basic data | Standard ID | GB/T 14055.2-2012 (GB/T14055.2-2012) | | Description (Translated English) | Reference neutron radiations -- Part 2: Calibration fundamentals of radiation protection devices related to the basic quantities characterizing the radiation field | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | F84 | | Classification of International Standard | 17.240 | | Word Count Estimation | 30,342 | | Older Standard (superseded by this standard) | GB/T 17437-1998 | | Quoted Standard | GB/T 14055.1-2008; ISO 8529-3-1998; ISO 12789; ICRU 33 Report-1980; ICRU 60 Report-1998; BIPM/IEC/IFCC/ISO/IUPAC/IUPAP/OIML-1993 | | Adopted Standard | ISO 8529-2-2000, IDT | | Regulation (derived from) | National Standards Bulletin No. 13 of 2012 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the GB/T 14055. 1-2008 given neutron field produced by neutron source to achieve the conditions of radiation protection instrumentation calibration methods, with particular emphasis on the correction of external influences (eg: the |
GB/T 14055.2-2012: Reference neutron radiations -- Part 2: Calibration fundamentals of radiation protection devices related to the basic quantities characterizing the radiation field ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Reference neutron radiations Part 2. Calibration fundamentals of radiation protection devices related to the basic quantities characterizing the radiation field
ICS 17.240
F84
National Standards of People's Republic of China
Replacing GB/T 17437-1998
Reference neutron radiation
Part 2. Characterization of the radiation field with the relevant basic amount
Radiation protection instrumentation calibration basis
Part 2. Calibrationfundamentalsofradiationprotectiondevicesrelated
(ISO 8529-2.2000, IDT)
Issued on. 2012-11-01 2012-06-29 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
1 Scope 1
2 Normative references 1
3 Terms and definitions
4 reference radiation fields traceable calibration and 3
5 radionuclide neutron source calibration General 4
Fixed 6 radionuclide neutron source scattering effect 6
7 linear OK 12
8 accelerators and reactor neutron source calibration 12
Nine pairs of special consideration personal dosimeter 14
10 15 Uncertainty
Appendix A (informative) Symbols used in this section 18
Annex B (informative) Room scattering contribution accounted for 40% minimum size of the room (Ref. [11]) 20
Annex C (normative) reduced air correction factor 21
Annex D (informative) total air scatter correction 22
Annex E (informative) shadow cone structure and use rules 23
Annex F (informative) to simplify the fitting parameters and variables explaining 24
References 25
Foreword
GB/T 14055 "Reference neutron radiation" is divided into three parts.
--- Part 1. Radiation characteristics and production method;
--- Part 2. Characterization of the radiation field and a substantial amount of the associated radiation protection instrumentation calibration basis;
--- Part 3. place dosimeters and personal dosimeters and determine the calibration energy and angular response.
This section GB/T 14055 Part 2.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This Part replaces GB /17437-1998 "method for determining neutron radiation protection measuring instruments calibrated and its response" T. Headquarters
Points and GB/T 17437-1998 major differences in content are.
a) The name of this section as modified according to a unified series of standards reference neutron radiation;
b) cancel the original standard Chapter 3, "covered by this standard instrument";
c) Terms and definitions canceled the original standard on angular response, join hands to expand radiation field, strongly penetrating radiation, the maximum dose equivalent shell,
By reference to instruments and monitoring instruments entries conventional true value increases the amount of dose equivalent, fluence, test point, the reference point and effective in
Entries heart;
d) an increase in the initial measurement of the corresponding formula and its detailed discussion;
e) increase in spherical geometry correction source and gives a typical example;
f) Data analysis in the original standard polynomial method to expand, given the more general universal fitting, intended to simplify and increase
legitimate;
g) cancel the original standard Appendix A "to test the physical properties of a schematic form", the original Standard Appendix B "recommendation on the phantom" Load
Part 1, section discussed in Part 3 of the standard, the original standard Appendix C "source strength characteristics of the two corner radionuclide neutron source" Load Standard
Points discussed;
h) the standard layout of the original structure has been a major adjustment, according to national standard template format changes.
This section uses the translation method identical with ISO 8529-2.2000 "neutron reference radiation - Part 2. Characterization of the radiation field and a substantial amount of phase
Radiation protection instrumentation calibration off base. "
This part of the National Nuclear Energy Standardization Technical Committee (SAC/TC58) centralized.
This section drafted by. China Institute of Atomic Energy.
The main drafters of this section. Liu Yina, Wang Zhiqiang, Chen Jun, Induced Exo - Chitinase Luo Hailong.
This part of the standard replaces the previous editions are.
--- GB/T 17437-1998.
Reference neutron radiation
Part 2. Characterization of the radiation field with the relevant basic amount
Radiation protection instrumentation calibration basis
1 Scope
This section provides the neutron source neutron field GB/T 14055.1-2008 given generated implement radiation protection instrument calibration conditions
Approach, with particular emphasis on external influences amendments (eg. Correction of the wall from the calibration laboratory of neutron scattering).
Due to the wide application of radionuclide neutron sources, this section focuses on radionuclide neutron source calibration (Chapter 4 ~ 6
Chapter), and for using the accelerator and reactor calibration (8.2 and 8.3) only briefly described.
ISO 8529-3 gives the conversion factors and the general rules and methods for calibration.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 14055.1-2008 neutron reference radiation - Part 1. Radiation characteristics and production method (ISO 8529-1.2001, IDT)
ISO 8529-3.1998 Reference neutron radiation - Part 3. Location and personal dosimeter calibration and determining the neutron energy response
Relationship between the amount and angle of incidence (Referenceneutronradiation-Part 3. Calibrationareaandpersonaldosimeters
anddeterminationofresponseasafunctionofenergyandangleofincidence)
ISO 12789 reference neutron radiation - simulated workplace neutron field characteristics and the production method (Referenceneutron
radiation-Characteristicsandmethodsofproductionofsimulatedworkplaceneutronfields)
No. ICRU33 Report. 1980 Radiation Quantities and units (Radiationquantitiesandunits)
No. ICRU60 Report.1998 the basic amount of ionizing radiation and units (Fundamentalquantitiesandunitsforionizing
radiation)
BIPM/IEC /IFCC/ISO /IUPAC/IUPAP/OIML.1993 General measurement terms and definitions (Internationalvocab-
ularyofbasicandgeneraltermsinmetrology)
3 Terms and Definitions
No. ICRU33 Report. 1980, Report No. ICRU60.1998 and BIPM/IEC /IFCC/ISO /IUPAC/IUPAP/OIML.
Defined in 1993 and the following terms and definitions apply to this document.
Appendix A lists the symbols used in this part.
3.1
Reading reading
The amount of the value of the instrument indication.
3.2
The amount of conventional true value conventionaltruevalueofaquantity
Best estimates are measured.
Note. In general that, for a given purpose conventional true value difference is small enough to be close to the true value.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 14055.2-2012_English be delivered?Answer: Upon your order, we will start to translate GB/T 14055.2-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 14055.2-2012_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 14055.2-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|