| US$459.00 · In stockDelivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
 GB/T 14049-2008: Aerial insulated cables for rated voltage of 10kV
 Status: Valid
 GB/T 14049: Evolution and historical versions
	
		
			| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |  
			| GB/T 14049-2008 | English | 459 | Add to Cart | 4 days [Need to translate] | Aerial insulated cables for rated voltage of 10kV | Valid | GB/T 14049-2008 |  
			| GB 14049-1993 | English | 679 | Add to Cart | 5 days [Need to translate] | Aerial insulated cables with rated voltages of 10kV and 35kV | Obsolete | GB 14049-1993 |  
	 
       PDF similar to GB/T 14049-2008 
 Basic data             | Standard ID | GB/T 14049-2008 (GB/T14049-2008) |           | Description (Translated English) | Aerial insulated cables for rated voltage of 10kV |           | Sector / Industry | National Standard (Recommended) |           | Classification of Chinese Standard | K13 |           | Classification of International Standard | 29.060.20 |           | Word Count Estimation | 20,217 |           | Date of Issue | 2008-06-30 |           | Date of Implementation | 2009-04-01 |           | Older Standard (superseded by this standard) | GB 14049-1993 |           | Quoted Standard | GB/T 1179-1999; GB/T 2951.1-1997; GB/T 2951.2-1997; GB/T 2951.5-1997; GB/T 3048.4-2007; GB/T 3048.5-2007; GB/T 3048.7-2007; GB/T 3048.8-2007; GB/T 3048.11-2007; GB/T 3048.12-2007; GB/T 3682-2000; GB/T 3953-1983; GB/T 3955-1983; GB/T 4909.2-1985; GB/T 4909.3-1985; GB/T 6995.3-2008; JB/T 8134-1995; JB/T 8137-1999; JB/T 10696.3-2007 |           | Regulation (derived from) | Announcement of Newly Approved National Standards No. 11 of 2008 (No. 124 overall) |           | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |           | Summary | This standard specifies the amount of voltage 10kV AC overhead insulated cable product models, specifications, technical requirements, test methods, inspection rules, packaging, transportation and storage. This standard applies to the amount voltage AC U (Um) to 10 (12) kV overhead power lines with copper, aluminum, aluminum alloy core cross-linked polyethylene and high density polyethylene insulated aerial cables. | GB/T 14049-2008: Aerial insulated cables for rated voltage of 10kV---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Aerial insulated cables for rated voltage of 10kV
ICS 29.060.20
K13
National Standards of People's Republic of China
Replacing GB 14049-1993
Rated voltage overhead insulated cable 10 k Vp
Posted 2008-06-30
2009-04-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
 Table of ContentsIntroduction Ⅲ
1 Scope 1
2 Normative references 1
3 Terms and definitions 1
4 Symbols and code 2
5 using the characteristics of 2
6 Models and Specifications 2
7 3 Technical requirements
8 9 Test Method
9 Acceptance Rule 10
10 packaging, transportation and storage 10
Appendix A (normative) overhead cable insulation material performance requirements of semi-conductive shielding material 11
Appendix B (normative) overhead cable insulation adhesion (slipping) Test Method 13
Annex C (normative) Artificial weathering test method (xenon lamp method) 15ForewordThis standard replaces GB 14049-1993 "rated voltage of 10kV, 35kV overhead insulated cables."
This standard compared with GB 14049-1993, the main changes are as follows.
--- Standard name changed to "rated voltage of 10kV overhead insulated cables";
--- Deleted on the rated voltage 35kV overhead insulated cable entry (1993 Edition Chapter 1, 3.1.3,4.1, Table 2, Table 3,
7.7.2, Table 5, Table 8);
--- Increasing the nominal cross section 400mm2 (Table 2, Table 3);
--- Delete Conductor Stranding pitch diameter ratio and a predetermined twist to the (1993 version 7.2.5);
--- A sign of increased core method (see 7.3.4);
--- Delete shielded cable insulation partial discharge as a routine test project (1993 version 7.7.4);
--- Modify the impulse voltage test value of 10kV overhead line (1993 edition Table 8 Table 8 of this standard);
--- According to GB/T 1.1-2000 modified format.
The Standard Appendix A, Appendix B and Appendix C are normative appendix.
The standard proposed by China Electrical Equipment Industrial Association.
This standard by the national wire and cable Standardization Technical Committee (SAC/TC213) centralized.
This standard was drafted. Shanghai Electric Cable Research Institute, Jiangsu Far East Group Co., Ltd., Haikou Wit Electric Group Co., Ltd., Fujian Nanping
Sun Cable Co., Ltd., Wuxi Jiangnan Cable Co., Ltd., Yangzhou Shuguang Cable Co., Ltd., Hunan Valin Cable Co., Ltd.
Drafters of this Standard. Sun Jiansheng, Wang Chuanbin, Mongolia Zhong Kui, Van der hair, Liu Jun, Liang Guohua, Zhang Gongzhuo.
This standard replaces the standards previously issued as follows.
--- GB 14049-1993.
Rated voltage overhead insulated cable 10 k Vp1 ScopeThis standard specifies the rated AC voltage of 10kV overhead insulated cables (overhead cable) product models, specifications, technical requirements, test side
Law, inspection rules, packaging, transportation and storage.
This standard applies to AC rated voltage U (Um) 10 (12) kV overhead power lines with copper, aluminum, aluminum alloy core crosslinked poly
Ethylene (XLPE) and high density polyethylene (HDPE) insulated aerial cables.2 Normative referencesThe following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 1179-1999 Round wire concentric gallows empty line (eqv IEC 61089.1991)
GB/T 2951.1-1997 cable insulation and sheathing materials test methods - Part 1. General Test Methods 1. Thick
Degree and dimension measurement - mechanical physical performance test (idt IEC 60811-1-1.1993)
GB/T 2951.2-1997 cable insulation and sheathing materials test methods - Part 1. General test methods - Part 2. Hot
Aging methods (idt IEC 60811-1-2. 1985)
GB/T 2951.5-1997 cable insulation and sheathing materials test methods - Part 2. General test elastomeric compounds Party
Act 1. Ozone resistance test - Hot set test - Mineral oil immersion test (idt IEC 60811-2-1. 1986)
GB/T 3048.4-2007 electrical wire and cable performance test methods - Part 4. Conductor DC resistance test
GB/T 3048.5-2007 electrical wire and cable performance test methods - Part 5. Insulation resistance test
GB/T 3048.7-2007 electrical wire and cable performance test methods - Part 7. Tracking resistance test
GB/T 3048.8-2007 electrical wire and cable performance test methods - Part 8. AC voltage test (IEC 60060-1. 1989,
NEQ)
GB/T 3048.11-2007 wire and cable electrical performance test methods - Part 11. dielectric loss tangent test
GB/T 3048.12-2007 wire and cable electrical performance test methods - Part 12. Partial discharge tests (IEC 60885-3.
1988, MOD)
GB/T 3682-2000 quality thermoplastic melt flow rate and melt volume flow rate measurement (idt ISO 1133.
1997)
GB/T 3953-1983 electrician round copper wire (neqASTMB1. 1970)
GB/T 3955-1983 electrician round aluminum (neqASTMB230. 1977)
GB/T 4909.2-1985 Test methods for bare wires sizing (neqIEC 60251. 1978)
GB/T 4909.3-1985 Test methods for bare wires tensile test (neqIEC 60207. 1966)
GB/T 6995.3-2008 wire and cable identification - Part 3. Wire and cable identification
JB/T 8134-1995 electrician round aluminum and aluminum alloy wire round Mg-Si alloy round wire
JB/T 8137-1999 (all parts) wire and cable delivery plate
JB/T 10696.3-2007 wire and cable mechanical and physical and chemical test methods - Part 3. Bending tests3 Terms and definitions3.1
Rated voltage is the reference voltage cable design and operation, represented by U (Um), in units of kV. U --- cable between two phase conductors
 
 Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 14049-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 14049-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 14049-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 14049-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries Question 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected] . In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 14049-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 14049-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.    |