US$619.00 · In stock Delivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 14048.7-2016: Low-voltage switchgear and controlgear -- Part 7-1: Ancillary equipment -- Terminal blocks for copper conductors Status: Valid GB/T 14048.7: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 14048.7-2016 | English | 619 |
Add to Cart
|
6 days [Need to translate]
|
Low-voltage switchgear and controlgear -- Part 7-1: Ancillary equipment -- Terminal blocks for copper conductors
| Valid |
GB/T 14048.7-2016
|
| GB/T 14048.7-2006 | English | 799 |
Add to Cart
|
4 days [Need to translate]
|
Low-voltage switchgear and controlgear -- Part 7-1: Ancillary equipment -- Terminal blocks for copper conductors
| Obsolete |
GB/T 14048.7-2006
|
| GB 14048.7-1998 | English | 799 |
Add to Cart
|
5 days [Need to translate]
|
Low-voltage switchgear and controlgear. Ancillary equipment. Section 1: Terminal blocks for copper conductors
| Obsolete |
GB 14048.7-1998
|
PDF similar to GB/T 14048.7-2016
Basic data | Standard ID | GB/T 14048.7-2016 (GB/T14048.7-2016) | | Description (Translated English) | Low-voltage switchgear and controlgear -- Part 7-1: Ancillary equipment -- Terminal blocks for copper conductors | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | K30 | | Classification of International Standard | 29.120.60 | | Word Count Estimation | 31,363 | | Date of Issue | 2016-02-24 | | Date of Implementation | 2016-09-01 | | Older Standard (superseded by this standard) | GB/T 14048.7-2006 | | Regulation (derived from) | National Standard Announcement No | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |
GB/T 14048.7-2016: Low-voltage switchgear and controlgear -- Part 7-1: Ancillary equipment -- Terminal blocks for copper conductors ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Low-voltage switchgear and controlgear - Part 7-1. Ancillary equipment - Terminal blocks for
ICS 29.120.20
K30
National Standards of People's Republic of China
Replace GB/T 14048.7-2006
Low-voltage switchgear and controlgear - Part 7-1.
Auxiliary device copper conductor terminal block
Part 7-1. Ancilaryequipment-Terminalblocksforcopperconductors
(IEC 60947-7-1..2009, MOD)
2016-02-24 released
2016-09-01 implementation
General Administration of Quality Supervision, Inspection and Quarantine of the People 's Republic of China
China National Standardization Management Committee released
Directory
Preface I
Basic requirements 1
2 terms and definitions
Category 3
4 Features 2
5 Product information 4
6 normal use, installation and transportation conditions 4
7 Structure and performance requirements 5
8 Test 6
Appendix A Blank 16
Appendix B (informative) Terms and Conditions relating to manufacturers and user agreements 17
Appendix C Blank 18
Appendix D (normative appendix) Additional requirements for isolated terminal blocks for testing 19
Reference 26
Foreword
GB 14048 "Low-voltage switchgear and control equipment" is divided into the following 21 parts.
- Part 1. General;
- Part 2. Circuit breakers;
- Part 3. switch, isolator, disconnector and fuse combination;
- Part 4-1. Contactors and motor starters Electromechanical contactors and motor starters (including motor protector);
- Part 4-2. Contactors and motor starters - AC semiconductor motor controllers and starters (including soft starters);
- Part 4-3. Contactors and motor starters - AC semiconductor controllers and contactors for non - motor loads;
- Part 5-1 Control circuit Electrical and switching elements Electromechanical control circuit appliances;
- Part 5-2. Control circuit appliances and switching element proximity switches;
- Part 5-3. Control circuit electronics and switching elements - Proximity switches (PDF) with definite function under fault conditions
Claim;
- Part 5-4. Control circuit appliances and switching elements - Evaluation of performance of small capacity contacts - Special tests;
- Part 5-5. Control circuit appliances and switching elements - Electrical emergency braking devices with mechanical latch function;
- Part 5-6. Control circuit appliances and switching elements - DC interface (NAMUR) for proximity sensors and switching amplifiers;
- Part 5-7. Control circuit appliances and switching elements for approaching equipment with analog outputs;
- Part 5-8. Control circuit appliances and switching elements - Three enable switches;
- Part 5-9. Control circuit appliances and switching element flow switches;
- Part 6-1. Multifunctional electrical switchgear;
- Part 6-2. Multifunctional electrical appliances (equipment) control and protection switchgear (equipment) (CPS);
- Part 7-1. Terminal blocks for auxiliary devices for copper conductors;
- Part 7-2. Protective devices - Protection conductors for copper conductors - Terminal blocks;
- Part 7-3. Safety requirements for auxiliary device fuses terminal blocks;
- Part 8. Loaded thermal protection (PTC) control unit for rotating electrical machines.
This section is part 7-1 of GB 14048.
This part is drafted in accordance with the rules given in GB/T 1.1-2009.
This part of the replacement GB/T 14048.7-2006 "Low-voltage switchgear and controlgear Part 7-1. auxiliary device copper conductor connection
Line terminal block ". The technical differences between this part and GB/T 14048.7-2006 are.
--- "Additional information" should be added by the manufacturer's content "g) Conventional free air heating current (Ith)" and increased
The annotations of the item;
--- Refer to 7.1.3 "Electrical Clearance and Creepage Distance" and 7.2.2 "Dielectric Properties" on "Terminal blocks without Uimp specified"
Its minimum clearance and creepage distances are described in Appendix A "." The manufacturer does not specify the rated impulse withstand
Voltage Uimp terminal block, the Uimp minimum see GB 14048.1-2012 Appendix H ";
--- 7.1.4 "Identification and marking of terminals" Added "For the identification of terminal blocks, yellow-green mixed colors are not allowed"
Last paragraph;
--- 7.1.5 "Non-normal heat and fire", after the first paragraph to add a sentence "GB 14048.1-2012 7.1.2.2 In addition to note,
Not applicable to this part ";
--- 7.1.6 "rated cross-sectional area and rated connection capacity", in the first paragraph after the addition of a "consistency verification can be based on 8.3.3.4
Test proceeding ";
--- 8.2 "General requirements for testing", add the last paragraph "If one of the terminal blocks can not pass one of the tests
Test, you need to repeat the test on the second set of terminal blocks, then all the terminal blocks should be repeated through the test. If this is the one
Test is a part of the test sequence, then all the test sequence should be repeated ";
--- 8.3.2, 8.3.3.2, 8.4.5 and 8.4.6 on the "thread diameter less than or equal to 2.8mm screw-type clamping parts, tightening torque
In accordance with the provisions of Table C.1 or the manufacturer's specified value "are changed to" tightening torque should be GB 14048.1-2012 in Table 4
Of the specified value, or according to the manufacturer specified higher torque value. ";
--- 8.3.3.4 "Verification of rated cross-sectional area and rated connection capability" Finally added a new section "Theoretical diameter of the largest conductor see
GB 14048.1-2012 in Table 7a (Correspondence between conductor cross-sectional area and diameter) ";
In the original appendix A, appendix B, appendix C, delete appendix A and appendix C, retain appendix B, and add new appendix D
(Normative). Additional requirements for isolating terminal blocks for testing.
This part uses the re-drafting method to modify the use of IEC 60947-7-1..2009 (version 3.0) "Low-voltage switchgear and control equipment
7-1 part. auxiliary device copper conductor terminal block ".
The technical differences between this part and IEC 60947-7-1..2009 are.
--- on the normative reference documents to GB 14048.1-2012 low-voltage switchgear and control equipment Part 1. General
(IEC 60947-1..2011, MOD) instead of IEC 60947-1..2007;
--- AC rated voltage 1140V electrical appliances can refer to this part of the implementation of the electrical performance requirements by the manufacturer and the user association
To determine;
- According to China's environmental and material requirements, supplemented by the relevant requirements of the damp-heat performance (7.1.7) and its test method (8.3.3.6)
And in the Appendix D made the appropriate editorial changes, that is, the clause No. D.7.1.7 changed to D.7.1.8;
--- For ease of understanding, add a note to the definition of "Terminal block", indicating that the terminal block in this section is made up of multiple wiring
Terminal block combination;
--- For ease of understanding, add the markings to the title of the Appendix D "Test Isolated Terminal Blocks" Also called 'Switch Type Terminals
Row "or" isolated terminal strip "and so on.
This part is made by China Electrical Equipment Industry Association.
This part of the national low-voltage electrical appliances Standardization Technical Committee (SAC/TC189) centralized.
This part is responsible for the drafting unit. Shanghai Electric Research Institute.
This part participates in the drafting unit. Phoenix China Investment Co., Ltd., Weidmüller Electric (Shanghai) Co., Ltd., Shanghai Engineering Technology
University of Technology, Zhejiang Province, high and low voltage electrical product quality inspection center, Shanghai electrical equipment testing.
This part of the main drafters. Zhang Lili, Huang Jingye, Wu Qingyun, Zhu Shiming, Wang Chengping, Pan Ying, Lin Jie, Sun Jinfeng
This part of the previous version of the standard to replace the release of the situation.
--- GB 14048.7-1998, GB/T 14048.7-2006.
Low-voltage switchgear and controlgear - Part 7-1.
Auxiliary device copper conductor terminal block
1 basic requirements
1.1 Scope
This part of GB 14048 specifies the installation of an electrical connection for copper conductors for use in industrial or similar applications on a support and
Mechanical connection of threaded or non-threaded terminal block requirements.
This part applies to the rated voltage AC does not exceed 1000V1), frequency to 1000Hz or DC does not exceed 1500V circuit, with
In the connection cross-sectional area of 0.2mm2 ~ 300mm2 (AWG24/600kcmil) with or without special processing of the round copper wire terminal
Sub-row.
1) AC rated voltage 1140V electrical appliances can refer to this part of the implementation. The requirements for electrical performance and other requirements are determined by the manufacturer and the user.
Note. AWG is an abbreviation for "American Wire Gauge"
kcmil = 1000cmil
1cmil = 1 round ear = diameter 1 mil round area
1mil = 1/1000 inch
The following products may use this section as a guide.
--- need to install a special device on the wire terminal block, such as fast connection terminals or connection connections;
- with the edge or tip puncture insulation to achieve direct contact with the wire terminal block, such as insulation transfer connections;
--- Special types of terminal blocks, such as terminal blocks with diodes or rheostats or similar component brackets.
When referring to GB 14048.1-2012, the term "clamping element" is used in this section instead of "terminal".
1.2 Normative references
The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article
Pieces. For undated references, the latest edition (including all modifications) applies to this document.
GB/T 5169.5-2008 Fire hazard testing for electric and electronic products - Part 5. Test flame flame flame test method,
Confirmation of test methods and guidelines (IEC 60695-11-5..2004, IDT)
GB 14048.1-2012 Low - voltage switchgear and controlgear - Part 1. General (IEC 60947-1..2011, MOD)
ISO 4046-4..2002 Glossary of paper, cardboard, pulp and related terms - Part 4. Paper and board grades and conversion products
2 terms and definitions
The terms and definitions defined in GB 14048.1-2012 and the following terms and definitions apply to this document.
2.1
Terminal block terminalblock
An insulating member having one or more terminal blocks which are insulated from each other and intended to be mounted on a holder.
Note. The terminal block (terminalblocks) that appear in this section is a combination of multiple terminal blocks.
2.2
Rated cross-section ratedcross-section
The maximum cross-sectional area of all connectable types of conductors specified by the manufacturer, the wires are hard wires (single-core and multi-strand) and cord
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 14048.7-2016_English be delivered?Answer: Upon your order, we will start to translate GB/T 14048.7-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 14048.7-2016_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 14048.7-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 14048.7-2016?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 14048.7-2016 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|