US$759.00 · In stock Delivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 13849.1-2013: Local telecommunication cables with polyolefin insulation and polyolefin sheath -- Part 1: General Status: Valid GB/T 13849.1: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 13849.1-2013 | English | 759 |
Add to Cart
|
6 days [Need to translate]
|
Local telecommunication cables with polyolefin insulation and polyolefin sheath -- Part 1: General
| Valid |
GB/T 13849.1-2013
|
| GB/T 13849.1-1993 | English | RFQ |
ASK
|
9 days [Need to translate]
|
Local telecommunication cables with polyolefin insulation and polyolefin sheath. Part 1: General
| Obsolete |
GB/T 13849.1-1993
|
| GB/T 13849-1992 | English | RFQ |
ASK
|
3 days [Need to translate]
|
(Polyolefin insulation and polyolefin sheath local communication cable)
| Obsolete |
GB/T 13849-1992
|
PDF similar to GB/T 13849.1-2013
Basic data | Standard ID | GB/T 13849.1-2013 (GB/T13849.1-2013) | | Description (Translated English) | Local telecommunication cables with polyolefin insulation and polyolefin sheath -- Part 1: General | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | K13 | | Classification of International Standard | 29.060.20 | | Word Count Estimation | 33,390 | | Older Standard (superseded by this standard) | GB/T 13849.1-1993 | | Quoted Standard | GB/T 2900.10-2001; GB/T 2951.11-2008; GB/T 2951.12-2008; GB/T 2951.13-2008; GB/T 2951.14-2008; GB/T 2951.41-2008; GB/T 2951.42-2008; GB/T 2952.1-2008; GB/T 2952.3-2008; GB/T 3048.9-2007; GB/T 3048.10-2007; GB/T 3953-2009; GB/T 6995.2-2008; GB/T 6995.3-200 | | Regulation (derived from) | National Standards Bulletin 2013 No. 10 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies: Copper polyolefin insulation moisture barrier polyolefin sheathed local communication cable structure, mechanical properties and electrical performance requirements, test methods, inspection rules and signs packaging. This standar |
GB/T 13849.1-2013: Local telecommunication cables with polyolefin insulation and polyolefin sheath -- Part 1: General ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Local telecommunication cables with polyolefin insulation and polyolefin sheath Part 1. General
ICS 29.060.20
K13
National Standards of People's Republic of China
Replacing GB/T 13849.1-1993
Polyolefin insulation and polyolefin sheath local communication cable
Part 1. General
withpolyolefininsulationandpolyolefinsheath-Part 1. General
Issued on. 2013-07-19
2013-12-02 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Introduction Ⅲ
1 Scope 1
2 Normative references 1
3 Terms and definitions 2
4 symbols, codes and product representation 3
5 conductor 4
6 Insulation 4
Seven pairs of line group (hereinafter referred to as pairs) 5
8 5 cable core
9 The basic unit of the insulated conductors 6 chromatography
10 basic units, ligation (with) super units and chromatographic 6
11 6 other end of the cable
12 to prepare line and business line to 9
13 aluminum - polyethylene sheath - (moisture barrier polyethylene sheath) 9
14 outer sheath 10
15 termite cable structure 11
16 flame retardant cable structure 11
17 11 Electrical Performance
18 mechanical and physical properties and environmental performance 16
19 environmental performance 16
16 20 Delivery length
21 Test Method 17
22 18 Inspection Rules
23 Mark, packing 21
Appendix A (normative) Insulation color Munsell color 22
Annex B (informative) Recommended cable core structural arrangement 23
Annex C (normative) Test method for color transfer 24
Annex D (normative) Test method for insulation resistance to compression 25
Appendix E (normative) Test method for peel strength between aluminum and polyethylene sleeve 26
Annex F (normative) finished cable bending performance test 28
Foreword
GB/T 13849 "polyolefin insulation and polyolefin sheath local communication cable" is divided into five sections.
--- Part 1. General;
--- Part 2. copper core, solid or foam (foam skin) polyolefin insulation, unfilled, moisture barrier polyethylene sheathed local telecommunication
cable;
--- Part 3. Copper conductor, solid or foam (foam skin) polyolefin insulation, Filled, moisture barrier polyethylene sheathed local telecommunication
cable;
--- Part 4. copper conductor, solid polyolefin insulation (unfilled), self-supporting, moisture barrier polyethylene sheathed local communication cable;
--- Part 5. Copper conductor, solid or foam (foam skin) polyolefin insulation, isolated (inner shield), moisture barrier polyethylene sheathed local
Communication cables.
This section GB/T 13849 Part 1.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This Part replaces GB/T 13849.1-1993 "polyolefin insulation and polyolefin sheathed local telecommunication cables - Part 1. General requirements"
Compared with GB/T 13849.1-1993, the main technical changes are as follows.
--- Modify the "skin foam polyolefin insulation" is defined (see 3.4,1993 version 3.5);
--- Increased conductor 0.7mm and 0.9mm sizes (see 5.1);
--- The "connect the conductors should be acid-free silver alloy solder and flux brazing or welding or cold welding, tensile strength at connection
No connection should not be lower than the adjacent tensile strength at 85% "in the" 85% "to" 90% "(see 5.2,1993 version 5.2);
--- Increasing the solid high density polyethylene and polypropylene, solid "after air oven heat aging performance wound" test conditions and requirements, and
The "cold-formed damage" to "low temperature winding test"; increase the effective length of the heat-shrinkable insulation test for the L = 200mm
Provisions (see Table 1);
--- The "arithmetic average of the stranding pitch of the finished cable to any line in the 3m length measured should not exceed 155mm." The
"No more than 155mm" was changed to "not more than 150mm" (see Chapter 7 edition of 7.3,1993);
--- The aluminum plastic composite tape from the nominal thickness "0.2mm" was changed to "not less than 0.15mm" (see the edition 13.2.1,1993
13.1.1);
--- Increase in finished cable polyethylene sheath removed mechanical and physical properties of high density polyethylene and flame retardant material tensile
Strength, elongation before and after aging, environmental stress cracking resistance requirements and heat shrinkage (see 13.3.4);
--- Increasing the suspension wire requirements (see 13.5);
--- Increasing the outer sheath 53 and 553, detailed provisions of the sheath 33 and Type 43, Type 23 and termite outer layer is loaded (see para. 14
chapter);
--- Increased requirements for flame retardant cable structure (see Chapter 15);
--- The main electrical performance on modified as follows (see Table 6).
• increasing the conductor size 0.7mm, 0.9mm DC resistance, resistance unbalance, capacitance unbalance attenuation requirements;
• Increased foam, foam skin polyolefin insulated cable attenuation index;
• Modify the Working capacitance index (Table 6,1993 version of Table 7 No. 4);
• The "sub-unit line between proximal all combinations of acoustic attenuation MS≥79" changed to between "sub-unit of the line for all combinations
The proximal end of the acoustic attenuation MS≥77 "(Table 6,1993 Version 7.1 Table No. 7);
• Added "dielectric strength test, the AC voltage can also be used, which VAC rms test voltage = VDC/2".
--- Added "mechanical and physical properties and environmental performance of the cable". Fill water permeability of cable, cable filled trickle performance, low temperature
Bending, combustion characteristics of self-supporting cable pull-off force and flame retardant cable requirements (see Table 8);
--- Increased provisions on environmental performance (see Chapter 18);
--- Revised provisions regarding test methods (see Chapter 20, Chapter 17 of the 1993 revision);
--- Modify the main raw material requirements are as follows.
• increase the insulation material properties shall comply with YD/T 760-1995, and to delete the corresponding appendix (see 6.1,
1993 version of Appendix L);
• Increased filling compounds and water blocking, blocking yarn specific performance should be consistent with YD/T 839-2000 and YD/T 1115-
Provisions of 2001 (see 8.2.3 and 14.1.6);
• increase the performance of the double-sided tape and plastic composite aluminum-plastic composite tape should be consistent with YD/T 723.2-2007 and YD/T 723.3-
2007 provisions, and delete the corresponding appendix (see appendix 14.2.4,1993 version 13.2.4 and M);
• increase the polyethylene sheath materials should be consistent with GB/T 15065-2009 provisions (see 13.3.1).
--- Deleted the Chapter 20 provisions of three packs requirements (see Chapter 20 of the 1993 edition).
This part is proposed by the China Electrical Equipment Industrial Association.
This part of the National Standardization Technical Committee Wire and Cable (SAC/TC213) centralized.
This section is responsible for drafting unit. Shanghai Electric Cable Research Institute.
Participated in the drafting of this section. Chengdu Putian Cable Co., Ltd., Jiangsu Tong Ding Optoelectronics Co., Ltd., Wenzhou Yaohua Telecommunication has
Ltd., Zhejiang, a boat Electronic Technology Co., Ltd., Zhejiang Zhaolong Cable Co., Ltd., Zhejiang is lead Optoelectronics Co., Ltd., Jiangsu Heng
Through cable Technology Co., Ltd., Shenzhen City Jiaxiang Technology Co., Ltd.
The main drafters of this section. Xinxiu Dong, Gao Huan, Song Jie, on behalf of Kang, Xiaoren Gui, Wang Sheng, Chen Jiande, Ni Donghua, Luo Ying Bao Huai Ping, Huangdong Lian.
This part of the standard replaces the previous editions are.
--- GB/T 13849.1-1993.
Polyolefin insulation and polyolefin sheath local communication cable
Part 1. General
1 Scope
This section GB/T 13849 specifies the Copper polyolefin insulation moisture barrier polyolefin sheath local communication cable structure, mechanical and physical
Performance and electrical performance requirements, test methods, inspection rules and signs packaging.
This section applies to Copper polyolefin manufacture, acceptance and use of polyolefin insulation moisture barrier sheathed local telecommunication cables.
This section provides cable can be used to transmit audio signals 2B D rate and integrated services digital network and the following digital signals can also be
For transmitting 2048kbit/s digital signals or analog signals below 150kHz. Under certain conditions, it can also be used to transfer
2048kbit/s or more digital signals.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 2900.10-2001 Electrotechnical terminology cable
GB/T 2951.11-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 11. General test side
Law --- --- Measurement of thickness and overall dimensions of mechanical tests
GB/T 2951.12-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 12. General test side
Law --- Thermal aging methods
GB/T 2951.13-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 13. General test side
Density determination method --- --- --- Water absorption tests - Shrinkage test
GB/T 2951.14-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 14. General test side
Low temperature test method ---
GB/T 2951.41-2008 cable and the cable Common test methods for insulating and sheathing materials Part 41. polyethylene and polypropylene
Mixed Methods specific environmental stress cracking resistance test --- --- --- melt index measurement method Direct measurement of combustion of carbon polyethylene
Black and (or) mineral filler content --- thermal gravimetric analysis (TGA) measurements of carbon black content --- microscopy assessment polyethylene carbon black points
Divergence
GB/T 2951.42-2008 cable and the cable Common test methods for insulating and sheathing materials Part 42. polyethylene and polypropylene
Mixture special test methods --- after-treatment temperature tensile strength and elongation at break after heat treatment test --- test --- winding hot air
--- Increased long-term thermal stability test after aging winding test --- --- determine the quality of the copper-catalyzed oxidative degradation test method
GB/T 2952.1-2008 cable outer sheath - Part 1. General
GB/T 2952.3-2008 cable outer sheath - Part 3. Non-metallic sheathed cable General protective layer
GB/T 3048.9-2007 electrical wire and cable performance test methods - Part 9. spark test of insulated cores
GB/T 3048.10-2007 wire and cable electrical performance test methods - Part 10. extruded sheath spark test
GB/T 3953-2009 electrician round copper wire
GB/T 6995.2-2008 wire and cable identification methods - Part 2. Standard colors
GB/T 6995.3-2008 wire and cable identification - Part 3. Wire and cable identification
Basic optical cable test methods. Part 2 GB/T 7424.2-2008 total cable specification
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 13849.1-2013_English be delivered?Answer: Upon your order, we will start to translate GB/T 13849.1-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 13849.1-2013_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 13849.1-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 13849.1-2013?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 13849.1-2013 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|