GB/T 13624-2008: Functional design criteria for safety parameter display system for nuclear power plants
Status: Valid

GB/T 13624: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 13624-2008English209 Add to Cart 3 days [Need to translate] Functional design criteria for safety parameter display system for nuclear power plants Valid GB/T 13624-2008
GB/T 13624-1992English319 Add to Cart 3 days [Need to translate] Functional design criteria for safety parameter display system for nuclear power plants Obsolete GB/T 13624-1992

PDF similar to GB/T 13624-2008


Standard similar to GB/T 13624-2008

GB/T 13286   NB/T 20318   NB/T 20149   GB/T 13631   GB/T 13629   GB/T 13626   

Basic data

Standard ID GB/T 13624-2008 (GB/T13624-2008)
Description (Translated English) Functional design criteria for safety parameter display system for nuclear power plants
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard F83
Classification of International Standard 27.120.20
Word Count Estimation 9,918
Date of Issue 2008-07-02
Date of Implementation 2009-04-01
Older Standard (superseded by this standard) GB/T 13624-1992
Quoted Standard GB/T 13628
Regulation (derived from) Announcement of Newly Approved National Standards No. 11 of 2008 (No. 124 overall)
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the nuclear power plant safety parameter display system function design criteria. This standard applies to nuclear power plant safety parameter display system design.

GB/T 13624-2008: Functional design criteria for safety parameter display system for nuclear power plants


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Functional design criteria for safety parameter display system for nuclear power plants ICS 27.120.20 F83 National Standards of People's Republic of China Replacing GB/T 13624-1992 Nuclear Power Plant Safety Parameter Display System Functional design criteria Posted 2008-07-02 2009-04-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

The reference to the standard IEC 60960 (1988) "Nuclear Power Plant Safety Parameter Display System Functional design criteria." This standard replaces GB/T 13624-1992 "Nuclear Power Plant Functional design criteria for safety parameter display system." This standard compared with GB/T 13624-1992 main changes are as follows. a) Delete Chapter 2 reference standard GB 12172's; b) In Chapter 3, Section 5 and Chapter 6 added content digitization. Appendix A of this standard is an informative annex. The standard proposed by China National Nuclear Corporation. This standard by the National Standardization Technical Committee on nuclear instrumentation. This standard was drafted. China Nuclear Power Institute. The main drafters of this standard. Ling Zhou Xiong Yan. This standard replaces the standards previously issued as follows. --- GB/T 13624-1992. Nuclear Power Plant Safety Parameter Display System Functional design criteria

1 Scope

This standard specifies the nuclear power plant safety parameter display system (SPDS) functional design criteria. This standard applies to the design of nuclear power plant safety parameter display system.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 13628 nuclear reactor protection system for the purpose of non-safety guidelines

3 Total performance requirements

3.1 The basic equipment for the control room operator to provide the reactor in normal, transient and accident conditions necessary for the safe operation of the information. SPDS used to enhance and complement the information. 3.2 SPDS by the meter, a display device and a computer to form a stand-alone system. In the digital design of nuclear power plants in the SPDS functions It can be integrated in the nuclear power plant and computer control systems, as part of the operator support systems, equipment and operator station shared. 3.3 SPDS in a concise manner to provide normal conditions to the control room staff, especially the abnormal condition information is used to help control room staff Quickly and reliably determine the security status of the plant. For example. the integrity of the reactivity control, reactor coolant system, reactor core cooling Cooling and a heat loop system export, radiological monitoring, containment integrity and so on. Although SPDS in normal conditions and abnormal conditions are working, but the main purpose and function is to assist SPDS control room staff in different And accident conditions often determine the security status of the plant and the estimated need for the operator to take corrective action to avoid the loss of core fuel elements Bad and radioactive releases. This occurs when a transient initial accident and the whole process of the accident is particularly important. 3.4 SPDS position control room staff should be easy to observe. The system should be able to provide data in order to quickly and reliably evaluate the safety of the plant status even Continued display information. 3.5 SPDS should be designed to be flexible enough so that it may be further advanced diagnostic concepts, advanced technologies and such assessment Expert systems as advanced systems combined. 3.6 Supplementary information is displayed (for example, consult the rules, trend information, and unconfirmed information, etc.) should be used as an actual branch SPDS Who show consideration.

4 Functional design criteria

Basic requirements 4.1 functional design 4.1.1 SPDS functional design guidelines apply to the control room and emergency response facilities. 4.1.2 SPDS should be designed to select a minimum set of parameters to assess the state of safety of the plant. Parameter selection and display should be able to raise High operator without the need for a comprehensive view of the control room, in a timely manner to assess the ability of the plant to the state. However, according to the commentary SPDS Assessment results, a control room to confirm additional information. 4.1.3 Upon detecting abnormal conditions of nuclear power plants, SPDS should immediately provide information and analysis to help diagnose this abnormal state and beyond Fruit, helping the operator to select the most effective corrective action. Suitable procedures may also be displayed on the display.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 13624-2008_English be delivered?

Answer: Upon your order, we will start to translate GB/T 13624-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 13624-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 13624-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 13624-2008?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 13624-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.