GB/T 13540-2009: Seismic qualification for high voltage switchgear and controlgear
Status: Valid

GB/T 13540: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 13540-2009English489 Add to Cart 4 days [Need to translate] Seismic qualification for high voltage switchgear and controlgear Valid GB/T 13540-2009
GB/T 13540-1992English639 Add to Cart 5 days [Need to translate] Anti-seismic characteristic test for high-voltage switchgear Obsolete GB/T 13540-1992

PDF similar to GB/T 13540-2009


Standard similar to GB/T 13540-2009

GB/T 19212.5   GB/T 10228   GB/T 25095   GB/T 16896.3   GB/T 31104   GB/T 16896.1   

Basic data

Standard ID GB/T 13540-2009 (GB/T13540-2009)
Description (Translated English) Seismic qualification for high voltage switchgear and controlgear
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K40
Classification of International Standard 29.130.10
Word Count Estimation 21,289
Date of Issue 2009-11-30
Date of Implementation 2010-04-01
Older Standard (superseded by this standard) GB/T 13540-1992
Quoted Standard GB 1984; GB 1985; GB/T 2423.43; GB/T 2423.48; GB/T 2424.25; GB 3906; GB 7674; GB/T 11022; GB/T 17467
Adopted Standard IEC 62271-2-2003, MOD
Regulation (derived from) Announcement of Newly Approved National Standards No. 13 of 2009 (No. 153 overall)
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the high-voltage switchgear and control equipment Hangzhou earthquake requirements, and clearly the use of analysis, test or a combination of the principles of validation Hang shock resistance. This standard applies to the nominal voltage of 3 kV and above, frequency 50 Hz, and below the power system running indoor and outdoor installation for all high-voltage switchgear and control equipment, including its rigid connection with the ground support structure.

GB/T 13540-2009: Seismic qualification for high voltage switchgear and controlgear

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Seismic qualification for high voltage switchgear and controlgear ICS 29.130.10 K40 National Standards of People's Republic of China Replacing GB/T 13540-1992 Seismic requirements of high-voltage switchgear and control equipment (IEC 62271-2.2003High-voltageswitchgearandcontrolgear- Part 2. Seismicqualificationforratedvoltagesof72.5kVandabove, MOD) Posted 2009-11-30 2010-04-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Introduction Ⅲ 1 Scope and purpose 1 2 Normative references 1 3 Terms and definitions 4 seismic performance test requirements 1 4.1 General 1 4.2 Preliminary analysis of 5 Earthquake Level 2 2 6 experimental verification 6.1 Overview 2 6.2 Installation 3 6.3 external load 3 6.4 Measurement 3 6.5 Frequency Range 3 6.6 Test Acceleration 3 6.7 Test 3 7 comprehensive validation testing and analysis 4 7.1 Overview 4 7.2 vibration and performance data 4 7.3 Numerical analysis 4 Evaluate the seismic performance of 8 5 Combination 8.1 Stress 5 Criterion 8.2 earthquake accredited test 6 8.3 Performance evaluation test results 6 8.4 allowable stress 6 9 Document 6 Seismic Performance Test Information 9.1 6 9.2 Test Report 6 9.3 Analysis Report 7 Characteristics Appendix A (normative) sample of 10 A. A low level of excitation 10 A. 2 free vibration test 10 Seismic performance and control equipment adequacy criterion switch Annex B (informative) 12 B. 1 Overview 12 B. 2 Recommended installation rules and practice 12 Annex C (normative) Seismic Verification Report 14 C. Example 14 1 Cover C. 2 seismic analysis to verify the contents of the report of example 14 C. Content 3 seismic test verification report Example 15 References 16

Foreword

This revised standard adopts IEC 62271-2.2003 "high-voltage switchgear and control equipment Part 2. Rated voltage 72.5kV and to Seismic requirements on ", while referring to the IEC 62271-207.2007" high-voltage switchgear and control equipment Part 207. Rated voltage Seismic requirements than 52kV gas insulated switchgear equipment "and IEC 62271-300.2006" high-voltage switchgear and control provided Test methods are cited GB/T 2423.43, GB/T 2423.48 and GB/T 2424.25 the three standards, this standard does not make Repeat; --- This standard is mainly used original product "fortification intensity of 8 degrees to 9 degrees strut porcelain high-voltage switchgear" extended to "the amount of Constant voltage 3.6kV and above all high-voltage switchgear and control equipment "(such as. high-voltage AC circuit breakers, high voltage AC isolation And earthing switches, 72.5kV and above gas-insulated metal-enclosed switchgear (GIS), 3.6kV ~ 40.5kV AC Metal-enclosed switchgear, HV/LV prefabricated substations, etc.); --- Applicable seismic ground level from the original horizontal acceleration 3m/s2 (corresponding to the reference seismic intensity Ⅷ ~ Ⅸ degree degrees) outward expansion Exhibition to 2m/s2,3m/s2,5m/s2 (corresponding to the reference seismic intensity were. < Ⅷ degrees, Ⅷ ~ Ⅸ degree degrees,> Ⅸ degree of = range; --- Standards adopted in response spectrum damping ratios of 2%, 5%, 10%, 20% and greater, and the original standard of 3%, 5%, 7%, 10%, 15%. Appendix A of this standard is a normative appendix, Appendix B, Appendix C are informative appendices. The standard proposed by China Electrical Equipment Industrial Association. This standard by the national high-voltage switch equipment Standardization Technical Committee (SAC/TC65) centralized. This standard is drafted by. Xi'an High Voltage Apparatus Research Institute. Participated in the drafting of this standard. Xi'an high-voltage electrical Co., Ltd., Henan high level of electrical Co., Ltd., New Northeast Electric (Shenyang) High Voltage Switchgear Co., Ltd., Zhengzhou Machinery Research Institute, China Electric Power Research Institute, Institute of high-voltage switch, Chint Electric Co. Shares The company, Ningbo Tianan (Group) Co., Ltd. Chuan Kai Electric Co., Ltd., China Siemens Power Transmission and Distribution Medium Voltage unit, Siemens (Hangzhou) High Voltage Switchgear Co. Ltd., ABB (China) Limited, ABB (China) Co., Ltd., Xiamen Branch, Xiamen ABB Huadian high-voltage switch Limited Division, Pacific Changzhou Power Equipment (Group) Co., Ltd. The main drafters of this standard. Yanyu Lin, Tian Enwen, Zhang Yan beads. Participate drafters of this standard. West Wang Yan Guan Xing, Zhang Shu, Liu Yumin, Yang , Liu Jingbo, Li carambola, Wang Jin root, Zhang Xijie, Dong Yan, I star, Zhang Tian Yun, Zhang Deqin, Zhupei Long, Wang Kai thereof, Yao Binbin, Huang Liqun, Xu Xianfeng, Zhang interlocking, Pan Ruiqiong, Yuan Chunping, Wang to grams, Zhang Yan. This standard replaces the standards previously issued as follows. --- GB/T 13540-1992. Seismic requirements of high-voltage switchgear and control equipment

1 Scope and purpose

GB 1984, GB 1985, GB/T 2424.25, GB 3906, GB 7674, GB/T 11022, GB 17467 terms and definitions established Apply to this standard.

4 seismic performance test requirements

4.1 General Seismic performance test shall verify the switching and control equipment, the ability to withstand seismic stress.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 13540-2009_English be delivered?

Answer: Upon your order, we will start to translate GB/T 13540-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 13540-2009_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 13540-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 13540-2009?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 13540-2009 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.