HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (25 Oct 2025)

GB/T 13434-2008 English PDF

US$819.00 · In stock
Delivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 13434-2008: Methods of measuring characteristics for discharge lamps (excluding fluorescent lamps)
Status: Valid

GB/T 13434: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 13434-2008English819 Add to Cart 6 days [Need to translate] Methods of measuring characteristics for discharge lamps (excluding fluorescent lamps) Valid GB/T 13434-2008
GB/T 13434-1992English679 Add to Cart 5 days [Need to translate] Test method for H. P. S. Lamps Obsolete GB/T 13434-1992

PDF similar to GB/T 13434-2008


Standard similar to GB/T 13434-2008

GB/T 43017   GB/T 19258.1   GB 19258   GB/T 45515   GB/T 17263   GB/T 24823   

Basic data

Standard ID GB/T 13434-2008 (GB/T13434-2008)
Description (Translated English) Methods of measuring characteristics for discharge lamps (excluding fluorescent lamps)
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K71
Classification of International Standard 29.140.30
Word Count Estimation 37,317
Date of Issue 2008-04-29
Date of Implementation 2008-12-01
Older Standard (superseded by this standard) GB/T 13434-1992
Quoted Standard GB/T 2900.65; GB/T 3978; GB/T 7922-2003; GB 15039; GB/T 15043-2008; GB/T 18661-2008; QB/T 2512; IEC 61167-1998; CIE 15
Adopted Standard ANSI C78.389-2004, NEQ
Regulation (derived from) Announcement of Newly Approved National Standards No. 6, 2008 (No. 119 overall)
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the high-pressure mercury lamp, high pressure sodium and include dysprosium lamps, sodium thallium, indium and scandium sodium lamp series, including single-ended and double-ended metal halide lamp characteristic measurement method. This standard applies to 50Hz AC power when needed together with the corresponding ballast and trigger, operating at rated supply voltage 92% to 106% of the high-pressure mercury lamp, sodium and including dysprosium lamps, sodium lamps indium and thallium sodium lamp series, including scandium single-ended and double-ended metal halide lamps.

GB/T 13434-2008: Methods of measuring characteristics for discharge lamps (excluding fluorescent lamps)


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods of measuring characteristics for discharge lamps (excluding fluorescent lamps) ICS 29.140.30 K71 National Standards of People's Republic of China Replacing GB/T 13434-1992 Discharge lamps (excluding fluorescent lamps) characteristic measurement method Posted 2008-04-29 2008-12-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Introduction Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 universal measuring environmental conditions 3 5 General measurement requirements 3 6 universal measuring system 3 7 common measurement method and calculation 8 Particular requirements for high pressure mercury lamp 8 Measurement 14 9 Particular requirements for high pressure sodium measurement methods 15 10 metal halide lamp 15 Particular requirements for methods of measurement (Normative) spectrum CIE standard photometric observer see Appendix A, as the function Vp (λ) 20 Annex B (informative) power supply system 21 Annex C (normative) recommended integrating sphere coating and formulation 22 Annex D (normative) color correction and absorption correction coefficient calculation 23 Appendix E (normative) measuring electrical parameters photoreduction Amendment Act 24 Annex F (informative) color parameter measurement schematic block diagram 25 Appendix H (normative appendix) UCS Figure 30 Slope Annex I (normative) correlated color temperature blackbody locus line and the intersection of the coordinates 31

Foreword

This corresponds to the standard American National Standards ANSIC78.389 "high intensity discharge lamps feature measuring method" (2004, in English). The degree of uniformity of standards and ANSIC78.389 not equivalent. This standard replaces GB/T 13434-1992 "Test Method for high-pressure sodium lamp characteristics." Since the implementation date of this standard of QB/T 2053-1994 "fluorescent high pressure mercury lamp optical parameters of measurement methods", QB/T 2515-2001 "The metal halide lighting electrical performance test methods" abolished. This standard compared with GB/T 13434-1993, the main differences are. increased or high pressure mercury lamp self-ballasted fluorescent high-pressure mercury lamp, dysprosium lamp, Startup characteristics including scandium sodium metal halide lamps and high pressure sodium lamp, light, electricity and color measurement methods. The Standard Appendix A, Appendix C, Appendix D, Appendix G, Appendix H, Annex I of normative appendix, Appendix B, Appendix E, Appendix F for the Informative appendix. The standard proposed by China National Light Industry Council. This standard by the National Standardization Technical Committee of electrical lighting (SAC/TC224) centralized. This standard was drafted. National Electric Light Source Quality Supervision and Inspection Center (Shanghai), Nanjing three Lok Lighting Co., Ltd., Shanghai Yaming Lighting Ltd., Philips Yaming Lighting Co., Ltd. (Prosperity Hangzhou) Lighting Appliance Co., Ltd., Beijing Institute of electric light. The main drafters of this standard. Lu Rong tree, Li Zhijun, Xue source, Wu Xiaojun, I'm following the steel, Cai Jianlong, Zhang Tieli, Jiang Shan, Zhao Xiurong. This standard was first published in 1992, this is the first revision. Discharge lamps (excluding fluorescent lamps) characteristic measurement method

1 Scope

This standard specifies the high-pressure mercury lamp, high pressure sodium lamp and include dysprosium, sodium thallium, indium and scandium sodium lamp series, including single-ended and double-ended metal halide Measurement was light characteristics. This standard applies to 50Hz powered by AC power, together with the appropriate ballast and trigger if necessary, operating at rated power supply voltage 92% to 106% of the high-pressure mercury lamp, sodium lamp and including dysprosium, sodium thallium, indium and scandium sodium lamp series, including single-ended and double-ended metal halide lamp (with Hereinafter referred to as the lamp).

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 2900.65 Electrotechnical terminology Lighting (GB/T 2900.65-2004, IEC 60050-845. 1987, MOD) GB/T 3978 standard lighting and illuminating - viewing conditions (GB/T 3978-1994, neqCIES001. 1986) GB/T 7922-2003 lighting color measurement method GB 15039 luminous intensity and luminous flux standard light bulb GB/T 15043-2008 incandescent lamps parameter measurement method GB/T 18661-2008 metal halide lamps (Scandium sodium series) QB/T 2512 cap temperature rise measurement method (QB/T 2512-2001, idt IEC 60360.1998) IEC 61167.1998 metal halide lamp CIE15 colorimetry

3 Terms and Definitions

GB/T 2900.65 determined and the following terms and definitions apply to this standard. 3.1 Aging 100h lamp when the measured optical, electrical and color parameters. 3.2 After switching on the lamp specified supply voltage, lamp voltage reaches the value of time required for a standard product requirements. 3.3 In the light of the two terminals of the lamp start properly and stable ignition of the minimum supply voltage rms. 3.4 Lamp at rated supply voltage from start to reach steady state. 3.5 At rated voltage, the maximum lamp current after the lamp is started when the 5s ~ 15s.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 13434-2008_English be delivered?

Answer: Upon your order, we will start to translate GB/T 13434-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 13434-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 13434-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 13434-2008?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 13434-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.