US$414.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 12162.4-2010: X and gamma reference radiation for calibrating dosimeters and dose rate meters and for determining their response as a function of photon energy -- Part 4: Calibration of area and personal dosimeters in low energy X reference radiation fields Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 12162.4-2010 | English | 414 |
Add to Cart
|
4 days [Need to translate]
|
X and gamma reference radiation for calibrating dosimeters and dose rate meters and for determining their response as a function of photon energy -- Part 4: Calibration of area and personal dosimeters in low energy X reference radiation fields
| Valid |
GB/T 12162.4-2010
|
PDF similar to GB/T 12162.4-2010
Standard similar to GB/T 12162.4-2010 GB/T 13286 NB/T 20318 GB/T 24247 GB/T 44632
Basic data | Standard ID | GB/T 12162.4-2010 (GB/T12162.4-2010) | | Description (Translated English) | X and gamma reference radiation for calibrating dosimeters and dose rate meters and for determining their response as a function of photon energy -- Part 4: Calibration of area and personal dosimeters in low energy X reference radiation fields | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | F85 | | Classification of International Standard | 17.240 | | Word Count Estimation | 21,240 | | Date of Issue | 2010-11-10 | | Date of Implementation | 2011-05-01 | | Quoted Standard | GB/T 12162.1-2000; GB/T 12162.2-2004; GB/T 12162.3-2004; JJF 1059; ICRU 51 | | Adopted Standard | ISO 4037-4-2004, IDT | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 8 of 2010 (total 163) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the reference in the low-energy X-ray radiation field calibration sites and individual dose (rate) instrument and to identify sites and individual dose (rate) instrument energy response and angular response approach. This section provides accurately determine the low-energy photon radiation spectrum from the air kerma to Hp (10) and H "(10) conversion factor, as well as through the appropriate standard instrument calibration based on these methods is directly in this section applies to the low-energy X-ray radiation field calibration reference sites and individual dose (rate) instrument and to identify sites and individual dose (rate) instrument energy response and angular response. |
GB/T 12162.4-2010: X and gamma reference radiation for calibrating dosimeters and dose rate meters and for determining their response as a function of photon energy -- Part 4: Calibration of area and personal dosimeters in low energy X reference radiation fields
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy.Part 4. Calibration of area and personal dosemeters in low energy X reference radiation fields
ICS 17.240
F85
National Standards of People's Republic of China
For calibrating dosemeters and dose rate meter and
Determining their response of X and γ reference radiations
Part 4. low-energy X-ray radiation reference field
Place and personal dosimeters calibration
photonenergy-Part 4. Calibrationofareaandpersonaldosemeters
(ISO 4037-4.2004, IDT)
Issued on. 2010-11-10 2011-05-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Introduction Ⅲ
1 Scope 1
2 Normative references 1
3 Terms and definitions
4 Symbols 2
General Method 5 calibration and determine the response of 3
Generation and low energy X reference radiation characteristics 6 4
6.1 Overview 4
6.2 Voltage 4
6.3 radiation field uniformity and scattered radiation 5
6.4 spectral fluence and conversion factor of 5
7 low energy reference radiation dosimetry 5
7.1 Overview 5
Use standard instrument 7.2 5
8 calibration response and determining the energy and angular response of 5
8.1 Overview 5
Select calibration method 8.2 of 5
8.3 with standard measuring instrument calibration Ka 6
8.4 with a standard measurement instrument calibration ICRU dose equivalents 8
8.5 9 Expression of Uncertainty
Appendix A (normative) air density correction 11
Annex B (informative) Measurement of pulse amplitude spectrum 15
References 17
Foreword
GB/T 12162 "for calibrating dosemeters and dose rate meters and for determining their response of X and γ reference radiations" is divided into four parts.
--- Part 1. Radiation characteristics and production methods;
--- Part 2. Energy range of radiation protection is 8keV ~ 1.3MeV and 4MeV ~ 9MeV reference radiation dose
Measurement;
--- Part 3. place dosimeters and personal dosimeters calibration response to determining its energy and angular response;
--- Part 4. low-energy X-ray radiation reference field sites and personal dosimeters calibration.
This section GB/T Part of 412,162.
This part of GB/T 12162 other part has a close relationship. GB/T 12162.1-2000 describes a photon reference radiation
Production and characteristics; GB/T 12162.2-2004 describes the reference radiation dosimetry; GB/T 12162.3-2004 depicts a
International Commission on Radiation Units and Measurements (ICRU) the amount of practical radiation protection [1,2,3] and determine the calibration dosimeters and dose rate meter response process
Preface; GB/T 12162.4 described for low-energy X reference radiation field of special methods.
This part identical with ISO 4037-4.2004 "for calibrating dosemeters and dose rate meters and for determining their response of X and γ reference
Radiation - Part 4. low-energy X-ray radiation reference field sites and personal dosimeters calibration. " Compared with the original standard, only a series
Series of modified to comply with the relevant requirements of national standards, the main change is as follows.
--- Delete the original standard foreword and introduction;
--- Other adaptations.
Appendix A of this section is normative appendix, Appendix B is an informative annex.
This part is proposed by the China National Nuclear Corporation.
This part of the National Nuclear Energy Standardization Technical Committee (SAC/TC58) centralized.
This section drafted by. China Institute of Atomic Energy.
The main drafters of this section. Wei Kexin, Song Mingzhe, Liu Qiaofeng, Houjin Bing.
For calibrating dosemeters and dose rate meter and
Determining their response of X and γ reference radiations
Part 4. low-energy X-ray radiation reference field
Place and personal dosimeters calibration
1 Scope
This section GB/T 12162 specifies the reference in the low energy X-ray radiation field calibration options and personal dose (rate) meters and determining field
The individual dose (rate) meter energy response and angular response of the method. This section provides an accurate determination of low energy photon radiation spectrum from the air kerma
Kinetic energy to Hp (10) and H * (10) of the conversion coefficient, and a method of directly by an appropriate instrument calibration standard according to these quantities.
This section applies to low-energy X-ray radiation field calibration reference sites and personal dose (rate) meters and to determine places and personal dose
(Rate) meter energy response and angular response.
2 Normative references
The following documents contain provisions which, through reference GB/T 12162 in this section constitute provisions of this section. For dated reference documents
Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section
Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this
section.
X and γ GB/T 12162.1-2000 for calibrating dosemeters and dose rate meters and for determining their response reference radiation first
Part I. Radiation characteristics and production methods (idtISO 4037-1.1996)
X and γ GB/T 12162.2-2004 for calibrating dosemeters and dose rate meters and for determining their response reference radiation 2
Parts. the energy range of radiation protection is 8keV ~ 1.3 MeV and 4 MeV ~ 9 MeV reference radiation dosimetry
(ISO 4037-2.1997, IDT)
GB/T 12162.3-2004 for calibrating dosemeters and dose rate meters and for determining their response of X and γ reference radiations 3
Part. place dosimeters and personal dosimeters calibrated response and its energy and angular response is determined (ISO 4037-3.1999, IDT)
JJF1059 Measurement Uncertainty and representation
No. ICRU51 report quantities and units of radiation protection dosimetry
3 Terms and Definitions
And the following terms and definitions GB/T 12162.3-2004 established applicable to this section.
3.1
Low-energy X-ray reference radiation lowenergyX-rayreferenceradiation
GB/T 12162.1-2000 and GB/T 12162.3-2004 specified nominal tube voltage lower than 30kV (including 30kV) by
Radiation quality.
Note. These radiation qualities for all filters and fluorescence radiation beam reference reference radiation.
3.2
Spectral fluence spectralfluence
Fluence Φ function of photon energy E distribution.
ΦE = dΦdE
(1)
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 12162.4-2010_English be delivered?Answer: Upon your order, we will start to translate GB/T 12162.4-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 12162.4-2010_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 12162.4-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|