US$509.00 ยท In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 12116-2012: General specification for electron voltmeter Status: Valid GB/T 12116: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 12116-2012 | English | 509 |
Add to Cart
|
4 days [Need to translate]
|
General specification for electron voltmeter
| Valid |
GB/T 12116-2012
|
| GB/T 12116-1989 | English | 639 |
Add to Cart
|
5 days [Need to translate]
|
Generic specification for electronic analog voltmeters
| Obsolete |
GB/T 12116-1989
|
PDF similar to GB/T 12116-2012
Basic data | Standard ID | GB/T 12116-2012 (GB/T12116-2012) | | Description (Translated English) | General specification for electron voltmeter | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | L85 | | Classification of International Standard | 17.220 | | Word Count Estimation | 22,212 | | Older Standard (superseded by this standard) | GB/T 12116-1989; GB/T 12117-1989 | | Quoted Standard | GB/T 191; GB/T 3047.6; GB/T 6587-2012; GB/T 11463-1989; GB/T 18268.1 | | Regulation (derived from) | National Standards Bulletin No. 41 of 2012 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the terms electronic voltmeter, product classification, requirements, test methods, inspection rules, marking, packaging, transport and storage. 3. 1. 1 This standard applies to the definition of voltmeter, voltmeter, including tho |
GB/T 12116-2012: General specification for electron voltmeter---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS17.220
L85
National Standards of People's Republic of China
Replacing GB/T 12116 ~ 12117-1989
General specification for electronic voltmeter
Issued on. 2013-06-01 2012-12-31 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
This standard rule according to GB/T 1.1-2009 given draft.
This standard replaces GB/T 12116-1989 "electronic analog voltmeters general technical conditions", GB/T 12117-1989 "analog electronic electricity
Pressure gauge General Test Methods. "
This standard and GB/T 12116-1989, GB/T 12117-1989 compared to the main changes are as follows.
--- Original GB/T 12116-1989 "electronic analog voltmeters General technical conditions" and GB/T 12117-1989 "analog electronic electricity
Pressure Test Methods "combined called" electronic voltmeter universal norms ";
--- Increasing the digital display calculation method (see 6.3.1) electronic voltage meter error measurement results;
--- The latest measured voltage standing-wave ratio (VSWR) method replaces the original measure voltage standing-wave ratio (VSWR) method (see
6.3.4);
--- Increasing the interface functions such terms and test methods (see 5.2.8, 6.3.7);
--- GB/T 12116-1989 "electronic analog voltmeters general technical conditions" only provides analog meter measurements indicated this
Amendment to the digital display of measurement results, with automatic range switching and having an interface function voltmeter are included.
The standard proposed by the Ministry of Industry and Information Technology of the People's Republic of China.
This standard by the National Standardization Technical Committee Electronic Measuring Instruments (SAC/TC153) centralized.
This standard was drafted. Chengdu Qianfeng Electronics Instrument Factory.
The main drafters of this standard. Feng Wensheng Chen Lu since Linhuai Xi.
This standard superseded standard previously issued as follows.
--- GB/T 12116-1989;
--- GB/T 12117-1989.
General specification for electronic voltmeter
1 Scope
This standard specifies the electronic voltmeter (hereinafter referred to as voltmeter) terms, product classifications, requirements, test methods, inspection rules, marks, packages
Loading, transportation and storage.
3.1.1 This standard applies to the definition of the voltmeter, including those supporting the application of voltage meter following accessories.
--- Divider;
--- Voltmeter connected in series resistors, inductors or capacitors;
--- Probe;
--- Used to calibrate voltmeters related accessories.
The standards also apply to the sensor or transducer other electricity or electricity into a voltage value, and measuring the voltage values
To measure electricity or other power equipment.
This standard as a product design, identification, production, use, testing technical basis, but also the development of product standards based on the voltmeter.
This standard does not apply to phase-sensitive voltmeter.
For a measuring resistance, voltage, current, capacitance, and other functions of the Meter, this standard applies only to voltage component.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated edition applies to this article
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 191 Packing Pictorial marking
GB/T 3047.6 desktop chassis electronics Series of basic dimensions
GB/T 6587-2012 General specification for electronic measuring instruments
GB/T 11463-1989 electronic measuring instrument reliability test
Part 1 Electrical equipment compatibility requirements GB/T 18268.1 measurement, control and laboratory use. General requirements
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1 generic term voltmeter
3.1.1
Electronic voltmeter electronvoltmeter
Electronic voltmeter means for measuring DC and AC voltage (either or both), and analog meter or a digital display of measurement results
Electronic measuring instruments.
3.1.2
Accessory attachment
Voltmeter to expand the performance characteristics for the purpose of permanent or non-permanent combination voltmeter with a circuit element or device (such as resistors
, Capacitors, filters and coaxial devices, etc.).
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 12116-2012_English be delivered?Answer: Upon your order, we will start to translate GB/T 12116-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 12116-2012_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 12116-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 12116-2012?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 12116-2012 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|