GB/T 1094.6-2011: Power transformers -- Part 6: Reactors
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 1094.6-2011English2179 Add to Cart 13 days [Need to translate] Power transformers -- Part 6: Reactors Valid GB/T 1094.6-2011

PDF similar to GB/T 1094.6-2011


Standard similar to GB/T 1094.6-2011

GB 1094.1   GB/T 1094.7   GB/T 1094.11   GB/T 1094.14   

Basic data

Standard ID GB/T 1094.6-2011 (GB/T1094.6-2011)
Description (Translated English) Power transformers -- Part 6: Reactors
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K41
Classification of International Standard 29.180
Word Count Estimation 99,925
Date of Issue 2011-07-29
Date of Implementation 2011-12-01
Older Standard (superseded by this standard) GB/T 10229-1988
Quoted Standard GB 1094.1-1996; GB 1094.2; GB 1094.3-2003; GB/T 1094.4-2005; GB 1094.5-2008; GB/T 1094.7; GB/T 1094.10-2003; GB 1094.11-2007; GB/T 4109; GB/T 4797.7; GB/T 7354; GB/T 13499-2002; GB/T 16927.1-1997; GB/T 17211; GB/T 20836; GB/T 20837; GB/T 25092; JB/T 5895; IEC/TR 60943-1998
Adopted Standard IEC 60076-6-2007, MOD
Regulation (derived from) Announcement of Newly Approved National Standards No. 12 of 2011
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard applies to the following reactors: shunt reactors, series reactor, including current limiting reactors, neutral earthing reactor power control reactors, motor starters reactor and the EAF series reactor, filter (tuning) reactance device, capacitor damping reactor, capacitor discharge reactor, grounding transformer (neutral point coupler), Petersen coil, HVDC and industrial flat wave reactor. But these reactors except: Rated capacity of less than 1 kvar single- phase reactor and the rated capacity of less than 5kvar three-phase reactors, various special reactors, for example

GB/T 1094.6-2011: Power transformers -- Part 6: Reactors

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Power transformers.Part 6. Reactors ICS 29.180 K41 National Standards of People's Republic of China Replacing GB/T 10229-1988 Power transformers - Part 6. Reactors (IEC 60076-6.2007, MOD) Issued on. 2011-07-29 2011-12-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Introduction Ⅴ Introduction Ⅶ 1 Scope 1 2 Normative references 1 3 Terms and definitions 2 3.1 Reactor Type 2 3.2 Other definitions 3 4 Symbols and abbreviations 5 5 Conditions 6 5.1 Overview 6 5.2 Earthquake Conditions 7 6 design, testing, and application of the deviation 7 7 Shunt Reactor 8 7.1 Overview 8 7.2 Design 8 7.3 Terms and Definitions 8 7.4 9 ratings 7.5 Temperature Rise 10 7.6 insulation level 10 7.7 Nameplate 10 7.8 Test 11 7.9 Deviation 18 8 limiting reactors and neutral grounding reactor 19 8.1 Overview 19 19 8.2 Design 20 8.3 Terms and Definitions 8.4 21 ratings 8.5 rated to withstand thermal and mechanical short-circuit current short circuit current 24 8.6 Temperature Rise 24 8.7 insulation level 24 8.8 Nameplate 24 8.9 Test 25 Deviation 31 8.10 9 filter reactor connected to the capacitor, damping reactor and the discharge reactor 32 9.1 Overview 32 32 9.2 Design 33 9.3 Terms and Definitions 9.4 34 ratings 9.5 ability to withstand the rated thermal short-circuit current and rated short-circuit current of the machine 36 9.6 withstand inrush current discharge capacity 36 9.7 Temperature Rise 37 9.8 insulation level 37 9.9 Nameplate 37 9.10 Test 38 9.11 deviation 42 10 grounding transformers (neutral couplers) 42 10.1 Overview 42 10.2 Design 43 10.3 Terms and definitions 43 10.4 Rating 44 10.5 Rated short time withstand current capability neutral 45 10.6 Temperature Rise 46 10.7 46 Insulation level 10.8 Nameplate 46 10.9 Test 47 10.10 Deviation 51 11 Petersen Coil 51 11.1 Overview 51 11.2 Design 51 11.3 Terms and definitions 51 11.4 Rating 52 11.5 Temperature Rise 53 11.6 54 Insulation level 11.7 Nameplate 54 11.8 Test 54 11.9 deviation 57 12 flat wave reactor 57 12.1 Overview 57 12.2 Design 57 12.3 Terms and definitions 58 12.4 Rating 59 12.5 Temperature Rise 60 12.6 60 Insulation level 12.7 Nameplate 60 12.8 Test 61 12.9 deviation 67 This section in Appendix A (informative) reg number and IEC 60076-6.2007 68 reg number control Annex B (informative) of this section with IEC 60076-6.2007 technical differences and their causes 70 Annex C (informative) reactor magnetizing characteristic 73 Annex D (informative) Shunt Reactor operation and application-specific information 79 Annex E (informative) three-phase reactor mutual reactance, coupling coefficient and the effective impedance 81 Annex F (informative) gap between the core and magnetic shielding hollow reactor loss of temperature correction 86 Room Annex G (normative) Dry-type reactor turn overvoltage test 87 Appendix H (informative) Short Circuit Test 88 Annex I (informative) resistors --- performance parameters and tests 89 References 91

Foreword

GB 1094 "Power Transformers" currently contains the following sections. --- Part 1. General; --- Part 2. temperature rise; --- Part 3. Insulation levels, dielectric tests and external insulation air gap; --- Part 4. Power transformers and reactors lightning impulse and switching impulse testing guidelines; --- Part 5. ability to withstand short circuit; --- Part 6. Reactors; --- Part 7. oil-immersed power transformer loading guidelines; --- Part 10. Determination of sound levels; --- Part 101. Determination of sound levels - Application guide; --- Part 11. Dry-type transformers. This is Part 6 GB 1094 series of standards. This section prepared in accordance with GB/T 1.1-2009 given rules. Before this part of the standard version, code-named GB/T 10229, IEC standard code corresponding to IEC 60289. Since the relevant IEC power converter Pressure is now the standard code are adjusted to the IEC 60076 series, to be coordinated with the IEC standard code and easy to use, this revision will Standard code according to the new IEC standard series to be adjusted. This Part replaces GB/T 10229-1988 "reactor." This portion of the GB/T 10229-1988 main changes are as follows. a) preparation of the format according to GB/T 1.1-2009 "Standardization Guide Part 1. Standard structure and drafting" and "Standardization Guide Part 2. The use of international standards" GB/T 20000.2-2009 provisions were modified; b) the standard name from the "reactor" to "Power transformers - Part 6. Reactors"; c) increasing the normative references; d) expanding the scope of the reactor; e) increasing the provision of various types of reactors terms and definitions; f) increased the symbols and abbreviations; g) supplementary dry-type reactor conditions of use, increasing the use of other special conditions; h) increasing the design, testing, and application of bias; i) increase the discharge reactor and HVDC technology related content with smoothing reactor, and has all kinds of original standard Technical contents of the reactor were adjusted; j) of each chapter in the original standard "definition" to "Terms and Definitions"; k) Added Appendix. This section uses redrafted law revision using IEC 60076-6.2007 "Power transformers - Part 6. Reactors" (in English). This section lists the reg number and in Appendix A 60076-6 IEC .2007 reg control list numbered. Taking into account China's national conditions, in using IEC 60076-6.2007 when this part has made several modifications. About the technical differences have been incorporated into positive This paper identifies and vertical single line in which they are involved with the provisions margin. These technical differences are given in Appendix B and List the reasons for your reference. This part of IEC 60076-6.2007 includes the following editorial changes. a) "this International Standard" be replaced by "this section"; b) Remove the IEC 60076-6.2007 Foreword; c) use the decimal point. "" instead of a comma as the decimal point "." This part is proposed by the China Electrical Equipment Industrial Association. This part of the National Standardization Technical Committee transformers (SAC/TC44) centralized. This section is drafted. Shenyang Transformer Institute, SUNTEN Ltd., Beijing Power Equipment Plant, TBEA Shenyang Transformer Group Co., Ltd., Baoding Tianwei Electric Co., Ltd., Xi'an Electric Transformer Co., Ltd., State Grid Electric Power Research Institute, Guangzhou Panyu Pearl electrical limited liability company, Siyuan Electric Co., Ltd. The first branch, Ningbo Ning variable Electric Co., Baoding Bao Ling Transformer Co., Ltd., Guangdong Power Grid Power Research Institute, Guangzhou Zhiguang Electric Co., Ltd., TBEA Hengyang Transformer Co., Ltd, and Power Electric Group. The main drafters of this section. Guo Yan, Sun Jun, Liu Yan, Li Xia, Ren Yumin, Zhang joy, Chen, - from the Perspective, Maoqi Wu, Hou Jianguo, Wang Hui, Zheng Quan, Xu Linfeng, easy Zhaolin, Yu Kung, Xuzi Hong, Zhang Xianzhong. This part replaces the GB/T 10229 was first released in 1988, this is the first revision.

Introduction

The purpose of this section is to be within the range of the reactor to provide technical parameters and experimental basis. This section also should be certain reactor Used to provide important information to help develop the technical specifications of the reactor. This part as much as possible reference to GB 1094 in other parts of the section related to the power transformer. However, since the reactor and the pressure swing It is some essential difference, so they need some special consideration in the reactor specification, testing and applications. This section includes these consider. Chapter 1 of this Part to Chapter 6 applies to all reactors, Chapter 7 to Chapter 12 corresponding to the different types of reactors. general , The chapter Chapter 7 to Chapter 12 corresponds to a class of reactors. Terms defined in this section more than a general definition in Chapter 3 applies to the entire section, Chapter 7 to Chapter 12 of each chapter Regulation Given a certain type of reactor and its definition, and applies only to that chapter. Chapter 7 to Chapter 12 have a unified structure. In this structure, the terms of the rating given reactor technical parameters provided by the user needs Basic Information. Test each chapter defines the terms used in this type of test reactor, and also includes a number of additional projects need To be negotiated when ordering. Appendix C, Appendix D, Appendix E, Appendix F, Appendix H and Appendix I provides further a type reactors use and testing of letter interest. Appendix G describes the room dry-type reactor turn overvoltage test. This section includes the dry and liquid immersion-type reactor, when certain clauses apply only to a particular an electric reactor, also made a clarification. Power transformers - Part 6. Reactors

1 Scope

GB 1094 This section applies to the following reactors. --- Shunt reactors; --- Series reactor, including limiting reactors, neutral grounding reactors, reactor power control, motor starter and arc reactor Furnace series reactors; --- Filter (tuning) reactor; --- Capacitor damping reactor; --- Capacitor discharge reactor; --- Grounding transformers (neutral couplers); --- Arc suppression coil; --- HVDC and industrial smoothing reactors. But these reactors except. --- 1kvar rated capacity of less than single-phase reactors and the rated capacity of less than 5kvar three-phase reactors; --- A variety of special reactors, such as. high-frequency line traps or reactors mounted on railway vehicle. If small reactors or special reactors without the appropriate standard, all or part of the contents of this section apply.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB 1094.1-1996 Power transformers - Part 1. General (eqvIEC 60076-1.1993) GB 1094.2 Power transformers - Part 2. Temperature Rise (GB 1094.2-1996, eqvIEC 60076-2.1993) GB 1094.3-2003 Power transformers Part 3. Insulation levels, dielectric tests and external insulation air gap (eqv IEC 60076-3.2000) GB/T 1094.4-2005 Power transformers - Part 4. Power transformers and reactors lightning impulse and switching impulse testing Then (IEC 60076-4.2002, MOD) GB 1094.5-2008 Power transformers Part 5. Ability to withstand short circuit (IEC 60076-5.2006, MOD) GB/T 1094.7 Power transformers - Part 7. oil-immersed power transformer loading guidelines (GB/T 1094.7-2008, IEC 60076-7.2005, MOD) GB/T 1094.10-2003 Power transformers - Part 10. Determination of sound levels (IEC 60076-10.2001, MOD) GB 1094.11-2007 Power transformers Part 11. Dry-type transformers (IEC 60076-11.2004, MOD) GB/T 4109 is higher than 1000V AC voltage bushings (GB/T 4109-2008, IEC 60137.2003, MOD) GB/T 4797.7 electric and electronic products Classification of environmental conditions of the natural environment earthquake vibration and shock conditions (GB/T 4797.7- 2008, IEC 60721-2-6.1990, IDT) GB/T 7354 partial discharge measurements (GB/T 7354-2003, IEC 60270.2000, IDT) GB/T 13499-2002 power transformer application guide (IEC 60076-8.1997, IDT) GB/T 16927.1-1997 high-voltage test techniques Part 1. General test requirements (eqvIEC 60060-1. 1989)

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 1094.6-2011_English be delivered?

Answer: Upon your order, we will start to translate GB/T 1094.6-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 9 ~ 13 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 1094.6-2011_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 1094.6-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.