US$329.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 10799-2008: Rigid cellular plastics -- Determination of the volume percentage of open cells and of closed cells Status: Valid GB/T 10799: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 10799-2008 | English | 329 |
Add to Cart
|
3 days [Need to translate]
|
Rigid cellular plastics -- Determination of the volume percentage of open cells and of closed cells
| Valid |
GB/T 10799-2008
|
| GB/T 10799-1989 | English | 559 |
Add to Cart
|
4 days [Need to translate]
|
Cellular plastics--Determination of volume percentage of open and closed cells of rigid materials
| Obsolete |
GB/T 10799-1989
|
PDF similar to GB/T 10799-2008
Basic data | Standard ID | GB/T 10799-2008 (GB/T10799-2008) | | Description (Translated English) | Rigid cellular plastics -- Determination of the volume percentage of open cells and of closed cells | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | G30 | | Classification of International Standard | 83.100 | | Word Count Estimation | 14,169 | | Date of Issue | 2008-01-04 | | Date of Implementation | 2008-09-01 | | Older Standard (superseded by this standard) | GB/T 10799-1989 | | Adopted Standard | ISO 4590-2002, MOD; ASTM D6226-2005, MOD | | Regulation (derived from) | National Standard Approval Announcement 2008 No.1 (Total No.114) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the rigid closed cell foam openings and volume determination of the percentage. This standard applies to contain a polymer membrane or cell wall is divided into many small cell foam, the cell may be openings (interlinked) or (not connected), or a composite of these types of closed cell. |
GB/T 10799-2008: Rigid cellular plastics -- Determination of the volume percentage of open cells and of closed cells ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Rigid cellular plastics. Determination of the volume percentage of open cells and of closed cells
ICS 83.100
G30
National Standards of People's Republic of China
Replacing GB/T 10799-1989
Rigid Foam
Determination of the volume percentage of open and closed cells
Posted 2008-01-04
2008-09-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
This standard is GB/T 10799-1989 "rigid foam volume percentage of open and closed test method" amendment, the original test
Li made reference to the international standard ISO 4590.2002 "rigid foam volume percentage of open and closed cells measured" reference test method
ASTMD6226-05 "rigid foam Test Method for opening percentage."
This standard replaces GB/T 10799-1989.
This standard compared with GB/T 10799-1989 main changes are as follows.
--- Test instrument and method of operation change. GB/T 10799-1989, respectively, using pressure variation method and volume expansion measurement method
The amount of impermeable volume, the use of instruments and methods of operation are not the same; only the measurement of the standard volumetric expansion method impermeable volume.
--- Test sample size change. GB/T 10799-1989 volume expansion method in the detection of sample size. length × width × thickness
(100mm × 30mm × 30mm); this standard, the standard sample is two cubes, dimensions. 2.5cm × 2.5cm ×
2.5cm. Another alternative is the two cylindrical shape, whose cross-sectional size of 6.25cm2, height 2.5cm.
--- Open, closed porosity change in calculation methodology. GB/T 10799-1989 detection data plotted by extrapolation; this standard directly
To detect data calculated by relevant formulas.
--- The method of cutting the surface of the cell formation change correction. GB/T 10799-1989 to surface area and volume of various geometric
At least three sets of samples, each take three samples, the apparent opening measurement sample volume fraction, and then plotted extrapolated correction; this
Standard, directly to a single test sample with a blade parallel to the surface of each of the two samples cut along three sides of each cube. Third
Two cubes produced a total of 16 smaller cubes, the surface area exposed and the number of openings bubble generated by cutting
Add as a double, then this measure is calculated to obtain a correction value.
Appendix B of this standard is a normative appendix, Appendix A is an information appendix.
The standard proposed by China National Light Industry Council.
This standard by the National Standardization Technical Committee of plastic products.
This standard was drafted. Jiangsu Province Product Quality Supervision and Inspection Institute, Beijing Technology and Business University.
The main drafters of this standard. Wang Yan, Zhu Yuhong, Zhou Xiaoling, Gan Chao, Chen Qian.
This standard replaces the standards previously issued as follows.
--- GB/T 10799-1989.
Rigid Foam
Determination of the volume percentage of open and closed cells
1 Scope
This standard specifies the rigid foam volume of open and closed cell percentage determination.
This standard applies to containing the polymer membrane or the cell wall is divided into many small cell foam, the cell may be perforated (phase
Pass) or closed (non-communicating) or these types of compound.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 6342-1996 foam rubber - Determination of linear dimensions (idt ISO 1923. 1981)
Accuracy GB/T 6379.4-2006 Measurement methods and results (trueness and precision) - Part 4. Determine the standard measurement direction
The basic method of method accuracy (ISO 5725-4.1994, IDT)
GB/T 8810-2005 rigid foam water absorption (ISO 2896.2001, MOD)
GB/T 12811-1991 rigid foam average cell size of the test method
ISO 4590.2002 Rigid foams of open and closed volume percentage of test methods
3 Terms and definitions, symbols
3.1 Terms and Definitions
The following terms and definitions apply to this standard.
3.1.1
Closed cell, and not other cell communication.
3.1.2
The cell wall is not completely closed, and the other cell, directly or indirectly connected.
3.1.3
The internal volume of the gas can not be adopted, including the solid polymer volume (cell walls, pillars), filling volume, the use of solid particles or fibers
Victoria closed cell volume caused by the individual and aggregate due to the rupture of the cell walls are interconnected but a group of small cell size and external communication is not.
3.1.4
Including the internal volume of the cell material and water seepage caused by cutting the surface of various irregular openings volume.
The following symbols apply to this standard.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 10799-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 10799-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 10799-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 10799-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 10799-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 10799-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|