US$799.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 10066.10-2005: Test methods for electro-heat installations -- Part 10: Direct arc furnaces Status: Obsolete
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 10066.10-2005 | English | 799 |
Add to Cart
|
4 days [Need to translate]
|
Test methods for electro-heat installations -- Part 10: Direct arc furnaces
| Obsolete |
GB/T 10066.10-2005
|
PDF similar to GB/T 10066.10-2005
Basic data | Standard ID | GB/T 10066.10-2005 (GB/T10066.10-2005) | | Description (Translated English) | Test methods for electroheat installations. Part 10: Direct arc furnaces | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | K60 | | Classification of International Standard | 25.180.10 | | Word Count Estimation | 20,223 | | Date of Issue | 2005-08-26 | | Date of Implementation | 2006-04-01 | | Older Standard (superseded by this standard) | GB/T 6542-1986 | | Adopted Standard | IEC 60676-2002, MOD | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 11 of 2005 (No. 85 overall) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People Republic of China, China National Standardization Administration Committee | | Summary | This standard specifies a direct determination of the three-phase arc furnace main parameters and technical operating characteristics of test conditions and methods. This section applies to the rated capacity equal to or greater than 500 kg of the three-phase direct electric arc furnace, including the three-phase AC electric arc furnace, ladle refining furnace DC arc furnace and so on. These furnaces suitable for use in the case of atmospheric or near atmospheric pressure melting and refining the charge liquid solid charge. This is also applicable to different three-phase furnace having one or more arc electrodes. |
GB/T 10066.10-2005: Test methods for electro-heat installations -- Part 10: Direct arc furnaces---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Test methods for electroheat installations.Part 10. Direct arc furnaces
ICS 25.180.10
K60
National Standards of People's Republic of China
Replace GB/T 6542-1986
Test method for electric heating device
Part 10. Direct electric arc furnace
(IEC 60676.2002, Industrial electroheatequipment-
Testmethodsfordirectarcfurnaces, MOD)
Released on.2005-08-26
2006-04-01 implementation
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
China National Standardization Administration issued
Content
Foreword I
1 Scope 1
2 Normative references 1
3 Terms and Definitions 1
4 Test items and general test conditions 5
4.1 General test conditions 5
4.2 Test item 5
4.2.1 Cold Test Project 5
4.2.2 Thermal Test Project 5
5 Test and measurement methods 5
5.1 Measurement of electrical insulation of high current lines 5
5.2 Measurement of cooling water flow and heat loss 6
5.3 Measurement of electrode movement speed 6
5.4 Inspection of furnace rated capacity 6
5.5 Short circuit test during normal operation (not applicable to DC arc furnace) 6
5.6 Determination of main operating parameters during power-on 9
5.7 Measurement of unit electrode loss 10
5.8 Phase sequence inspection 10
Figure 1 High current line (three-phase short circuit) resistance and reactance measurement circuit Figure 11
Figure 2 High current line (single phase short circuit) resistance and reactance measurement circuit Figure 12
Figure 3 Configure a saturable reactor a. c electric arc furnace circuit legend 13
Appendix A (informative appendix) This part of the chapter number is compared with the IEC 60676.2002 chapter number 14
Appendix B (informative) The technical differences between this part and IEC 60676.2002 and their causes 15
Foreword
GB/T 10066 "Test methods for electric heating devices" has 12 parts.
--- Part 1. General part;
--- Part 2. Heart induction furnace;
--- Part 3. Unintentional induction furnace;
--- Part 4. Indirect resistance furnace;
---Part 5. Plasma device (GB/T 13535-1992 "Test method for plasma equipment for electric heating");
--- Part 6. Determination method of output power of industrial microwave heating equipment (GB/T 18662-2002 "Industrial microwave heating equipment
Method for measuring the output power");
---Part 7. Electrothermal devices with electron guns;
---Part 8. Electroslag remelting furnace (GB/T 1020-1989 "Test method for electroslag remelting furnace");
---Part 9. Method for measuring the output power of high-frequency dielectric heating devices (GB/T 14809-2000 "High-frequency dielectric heating equipment transmission
Measuring method of output power");
--- Part 10. Direct electric arc furnace;
--- Part 11. Submerged arc furnace;
--- Part 12. Method for measuring the output power of high-frequency induction heating devices (under development).
Note. Some existing electrothermal devices are tested without a segment number (as shown in parentheses) and will be changed to the segment number specified above when revised.
This part is part 10 of GB/T 10066 and should be used in conjunction with Part 1.
This part of the revision uses IEC 60676.2002 "Industrial Electric Heating Equipment - Test Method for Direct Electric Arc Furnace" (Second Edition, English version).
This section was redrafted in accordance with IEC 60676.2002. For the sake of comparison, the informative Appendix A lists the provisions of this section.
A checklist of IEC 60676.2002 clauses.
In order to maintain consistency with other industrial electrothermal device test method standards, this part was made when IEC 60676.2002 was adopted.
These modifications complement the test project and its test methods. These technical differences are identified by vertical single lines on the side of the terms they are involved in.
Blank space on the page. A list of these technical differences and their causes is given in Appendix B for reference.
For ease of use, the following editorial changes have been made to this part of IEC 60676.2002.
a) the word “this standard” is replaced by the words “this part”;
b) remove the preface and preamble of international standards;
c) Change "Industrial electric heating equipment - Test method for direct electric arc furnace" as "Test method for electric heating devices - Part 10. Direct electric
Arc Furnace, the English name corresponds to the modification;
d) The standard chapter number is corresponding to the chapter number of the test method standard of other types of industrial electric heating devices;
e) classify the test items in cold and hot conditions;
f) In the article, the words “quality” and “weight” are changed to “quality”.
This part replaces GB/T 6542-1986 "Test Method for Direct Electric Arc Furnace", and the main technical changes compared with the latter are as follows.
a) In “3 Terms and Definitions”, the following terms have been added in accordance with IEC 60676.2002.
---Electric arc furnace device;
---Arc furnace shell;
---The rated capacity of the furnace;
--- rated capacity of the furnace;
--- The minimum cumulative proportion of scrap required to complete the maximum charge at one time;
---The furnace high voltage switch;
--- rated capacity of electric arc furnace transformer;
--- The melting power that the electric arc furnace transformer can provide;
---Saturated reactor;
---DC reactor; (only for DC arc furnace)
---Controllable rectifier; (only for DC arc furnace)
---Arc furnace electrode;
---Electric arc furnace electrode holder;
---High current line;
---Net power-on time;
---productivity;
--- Phase sequence.
The following terms have been modified.
---Electric arc furnace;
---Electric arc furnace transformer;
--- Primary side asymmetry coefficient; (not applicable to DC arc furnace)
--- The active power of the main circuit of the electric arc furnace equipment;
---Unit melting power consumption;
---The main circuit power factor of the electric arc furnace device;
---Cooling water flow;
---Run short circuit;
---The electric arc furnace device is cold;
---The furnace is hot.
b) According to GB/T 10066.1-2004 "Testing methods for electric heating equipment - Part 1. General part", the original test items are cold and hot.
State classification.
c) Supplementary provisions for general test conditions.
---Specify the test conditions according to the cold and hot state;
--- Increased requirements for process, charge and measuring instruments.
d) Revised the measurement of the original water consumption.
--- Change the water consumption measurement to the measurement of cooling water flow and loss.
e) Added Appendix A and Appendix B.
Appendix A and Appendix B of this part are informative annexes.
This part was proposed by China Electrical Equipment Industry Association.
This part is under the jurisdiction of the National Technical Committee for Standardization of Industrial Electric Heating Equipment.
This section drafted by. Xi'an Electric Furnace Research Institute.
The main drafters of this section. Hu Shuliang, Pan Binyun, Liu Xiping.
The previous versions of the standards replaced by this section are. GB/T 6542-1986.
Test method for electric heating device
Part 10. Direct electric arc furnace
1 Scope
This part of GB/T 10066 specifies the test conditions and methods for determining the main parameters and technical operating characteristics of a three-phase direct arc furnace.
This section applies to three-phase direct arc furnaces with rated capacity equal to or greater than 500kg, including three-phase AC electric arc furnace, ladle refining furnace,
DC electric arc furnace, etc. These furnaces are suitable for melting solid charge and refining liquid charge at or near atmospheric pressure.
This section also applies to electric arc furnaces with one or more electrodes that are different from three-phase furnaces.
An electric arc furnace that melts ferrous metals (such as steel, iron) and non-ferrous metals (such as copper) can also be used as a holding furnace for liquid charge discharging.
Pre-heating and insulation.
The purpose of this section is to standardize the test conditions and methods for determining the main parameters and technical operating characteristics of an electric arc furnace.
Note 1. These tests are performed independently of the compensation equipment.
This section does not contain all the test methods that may be performed for EAF technology and economic evaluation.
Note 2. Supplemental test conditions are negotiated between the manufacturer and the user.
For the testing of some special equipment for DC arc furnaces, such as the test of controlled rectifiers, see GB/T 3859.1-1993.
2 Normative references
The provisions in the following documents become the provisions of this part by reference to this part of GB/T 10066. Quotations with dated
, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouragement is achieved under this section
The parties to the agreement study whether the latest versions of these documents can be used. For undated references, the latest edition applies to this
section.
GB/T 2900.23 Electrical terminology industrial electric heating equipment (neqGB/T 2900.23-1995, IEC 60050 (841). 1983
GB/T 3859.1-1993 Specification for basic requirements for semiconductor converters (eqv IEC 60146-1-1.1991)
GB/T 10066.1-2004 Test methods for electric heating equipment - Part 1. General part (IEC 60398..1999, Industrial
Electroheatinginstalations-Generaltestmethods, MOD)
3 Terms and definitions
The terms and definitions established in GB/T 2900.23 and the following definitions apply to this section.
3.1
A furnace with an electric arc as its main source of heat.
3.2
The arc is maintained in an electric arc furnace between the charge and one or more electrodes.
3.3
Complete arc furnace installation with all electrical equipment, containing.
a) The main circuit includes.
---High voltage equipment;
---AC reactor (if used);
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 10066.10-2005_English be delivered?Answer: Upon your order, we will start to translate GB/T 10066.10-2005_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 10066.10-2005_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 10066.10-2005_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|