US$154.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 5023.4-2008: Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V -- Part 4: Sheathed cables for fixed wiring Status: Valid GB/T 5023.4: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 5023.4-2008 | English | 154 |
Add to Cart
|
3 days [Need to translate]
|
Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V -- Part 4: Sheathed cables for fixed wiring
| Valid |
GB/T 5023.4-2008
|
GB 5023.4-1997 | English | 199 |
Add to Cart
|
3 days [Need to translate]
|
Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V. Part 4: Sheathed cables for fixed wiring
| Obsolete |
GB 5023.4-1997
|
GB 5023.4-1986 | English | RFQ |
ASK
|
3 days [Need to translate]
|
Polyvinyl chloride insulated cables (wires) for rated voltages up to and including 450/750V insulated wires for internal wiring of equipment
| Obsolete |
GB 5023.4-1986
|
PDF similar to GB/T 5023.4-2008
Basic data Standard ID | GB/T 5023.4-2008 (GB/T5023.4-2008) | Description (Translated English) | Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V -- Part 4: Sheathed cables for fixed wiring | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | K13 | Classification of International Standard | 29.060.20 | Word Count Estimation | 8,872 | Date of Issue | 2008-06-30 | Date of Implementation | 2009-05-01 | Older Standard (superseded by this standard) | GB 5023.4-1997 | Quoted Standard | GB/T 2951.11-2008; GB/T 2951.12-2008; GB/T 2951.14-2008; GB/T 2951.31-2008; GB/T 2951.32-2008; GB/T 3956-1997; GB/T 5023.1; GB/T 5023.2-2008; GB/T 18380.12-2008; IEC 60719-1992 | Adopted Standard | IEC 60227-4-1997, IDT | Regulation (derived from) | Announcement of Newly Approved National Standards No. 11 of 2008 (No. 124 overall) | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | Summary | This standard specifies the rated voltage 300/500V light PVC sheathed cable 's technical requirements. All cables shall comply with GB/T 5023. 1 appropriate requirements prescribed in this section and the special requirements. |
GB/T 5023.4-2008: Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V -- Part 4: Sheathed cables for fixed wiring ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V. Part 4. Sheathed cables for fixed wiring
ICS 29.060.20
K13
National Standards of People's Republic of China
GB/T 5023.4-2008/IEC 60227-4.1997
Replacing GB 5023.4-1997
Rated voltage 450/750 and below Vp
PVC insulated cables
Part 4. Sheathed cables for fixed wiring
(IEC 60227-4.1997, IDT)
Posted 2009-05-01 2008-06-30 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
GB/T 5023 "rated voltage 450/750V and below PVC insulated cables" is divided into seven parts.
--- Part 1. General requirements;
--- Part 2. Test methods;
--- Part 3. Non-sheathed cables for fixed wiring;
--- Part 4. Sheathed cables for fixed wiring;
--- Part 5. Flexible cables (cords);
--- Part 6. Lift cables and cables for flexible connection;
--- Part 7. two-core or multi-core shielded and unshielded cable.
This section GB/T 45023 Part of. This section identical with IEC 60227-4.1997 "rated voltage 450/750V and with
Under PVC insulated cables Part 4. Sheathed cables for fixed wiring "Version 2.1 (in English).
For ease of use, GB/T 5023 made this part of the following editorial changes.
"." --- With a decimal point instead of a comma as the decimal point, "";
--- Remove the IEC 60227-4.1997 Foreword.
This Part replaces GB 5023.4-1997 "rated voltage 450/750V and below PVC insulated cables Part 4. Fixed cloth
Sheathed cable line. "
This section of the main changes compared to GB 5023.4-1997 are as follows.
--- Normative references added to the following documents.
IEC 60719.1992 rated voltage 450/750V and below average round copper conductor cable outer diameter of upper and lower limits of computing
method;
--- Table 1 Table Added note. The 1992 regulations. IEC 60719 calculation of the lower limit of the average non-compliance on the outer diameter of the cable.
This part is proposed by the China Electrical Equipment Industrial Association.
This part of the National Standardization Technical Committee Wire and Cable (SAC/TC213) centralized.
This part of the unit responsible for drafting. Shanghai Electric Cable Research Institute.
Participated in the drafting of this section. Far East Cable Factory, Tianjin Jinshan Electric Wire & Cable Co., Ltd., Jiang Su Shengan Cable Co., Ltd., Nanchang
Cable Co., Ltd., Jiangsu on the cable Group Co., Ltd., Hunan Cable Co., Ltd. Gold can.
The main drafters of this section. Lu Yanhong, Wang Chuanbin, Zheng Guojun, Sun Ping, Ding Xiaoqin, Li Bin, Yi Weimin.
This part of the standard replaces the previous editions are.
--- GB 5023.2-1985;
--- GB 5023.4-1997.
GB/T 5023.4-2008/IEC 60227-4.1997
Rated voltage 450/750 and below Vp
PVC insulated cables
Part 4. Sheathed cables for fixed wiring
1 General
1.1 Scope
GB/T 5023 this part of the detailed provisions of the rated voltage of 300/500V technical requirements for light PVC sheathed cable.
All cables shall comply with applicable requirements and special requirements of this part of GB/T 5023.1 regulations.
1.2 Normative references
The following documents contain provisions which, through GB/T reference in this 5023 constitute provisions of this part. For dated reference documents
Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section
Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this
section.
GB/T 2951.11-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 11. General test side
Law --- --- Measurement of thickness and overall dimensions of mechanical tests (IEC 60811-1-1.2001, IDT)
GB/T 2951.12-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 12. General test side
Law --- Thermal aging methods (IEC 60811-1-2. 1985, IDT)
GB/T 2951.14-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 14. General test side
Law --- Low temperature test (IEC 60811-1-4. 1985, IDT)
GB/T 2951.31-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 31. Polyvinyl chloride mixture
Methods specific high temperature pressure test --- --- resistance to cracking (IEC 60811-3-1. 1985, IDT)
GB/T 2951.32-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 32. Polyvinyl chloride mixture
Special test methods --- --- Loss of mass test - Thermal stability test (IEC 60811-3-2. 1985, IDT)
GB/T 3956-1997 cable conductor (idt, IEC 60228. 1978)
GB/T 5023.1 rated voltage of 450/750 V and below PVC insulated cables - Part 1. General requirements
(GB/T 5023.1-2008, IEC 60227-1.2007, IDT)
GB/T 5023.2-2008 rated voltage of 450/750V or less PVC insulation - Part 2. Test methods
(IEC 60227-2.2003, IDT)
GB/T 18380.12-2008 burning test and optical fiber cables under fire conditions - Part 12. single insulated wire and cable fire
Vertical flame spread test (IEC 60332-1-2.2004, IDT)
IEC 60719.1992 rated voltage 450/750V or less round average outer upper and lower copper conductor cable and calculation method
2 Light PVC sheathed cable
2.1 Model
60227IEC 10 (BVV).
2.2 Rated voltage
300/500V.
GB/T 5023.4-2008/IEC 60227-4.1997
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 5023.4-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 5023.4-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 5023.4-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 5023.4-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 5023.4-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 5023.4-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|