US$209.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB 16895.29-2008: [GB/T 16895.29-2008] Electrical installations of buildings -- Part 7-713: Requirements for special installations and locations -- Furniture Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB 16895.29-2008 | English | 209 |
Add to Cart
|
3 days [Need to translate]
|
[GB/T 16895.29-2008] Electrical installations of buildings -- Part 7-713: Requirements for special installations and locations -- Furniture
| Valid |
GB 16895.29-2008
|
PDF similar to GB 16895.29-2008
Basic data | Standard ID | GB 16895.29-2008 (GB16895.29-2008) | | Description (Translated English) | [GB/T 16895.29-2008] Electrical installations of buildings -- Part 7-713: Requirements for special installations and locations -- Furniture | | Sector / Industry | National Standard | | Classification of Chinese Standard | Q77 | | Classification of International Standard | 91.140.50 | | Word Count Estimation | 8,828 | | Date of Issue | 2008-12-15 | | Date of Implementation | 2010-02-01 | | Adopted Standard | IEC 60364-7-713-1996, IDT | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 21 of 2008 (No. 134 overall) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This Chinese standard applies to electrical devices connected to the furniture (and similar furniture) cabling system. For example: with lamps, sockets, electrical switches, wiring systems and other electrical equipment, beds, cabinets, tables and store display cabinets. Requirements of this standard apply to fixed wiring connected to the electrical installations of buildings furniture, but also applies to finished furniture and furniture supply with plug and socket, the furniture in other countries unless otherwise specified in the standard. Furniture, electrical equipment shall be connected within not more than 240V single- phase power supply line, the total load current should not exceed 16A. These requirements do not apply to furniture specially designed for installation in the other provisions of national standards for electrical appliances and electrical equipment, such as: the ease of installation in furniture to the building through a plug and socket connection |
GB 16895.29-2008: [GB/T 16895.29-2008] Electrical installations of buildings -- Part 7-713: Requirements for special installations and locations -- Furniture ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Electrical installations of buildings.Part 7-713. Requirements for special installations and locations.Furniture
ICS 91.140.50
Q77
National Standards of People's Republic of China
GB 16895.29-2008/IEC 60364-7-713.1996
Electrical installations of buildings
Requirements for special installations or locations. Section 7-713
Furniture
(IEC 60364-7-713.1996, IDT)
Posted 2008-12-15
2010-02-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
Introduction Ⅱ
1 713 Furniture
713.1 Overview 1
713.1.1 Scope 1
713.1.2 Normative references 1
713.1.3 Definition 2
Selection and installation of electrical equipment 2 713.5
713.51 General Rule 2
713.52 wiring system 2
713.55 Other equipment 3
GB 16895.29-2008/IEC 60364-7-713.1996
Foreword
GB (/ T) all the technical content of this section 16895 is mandatory.
GB (/ T) 16895 "Electrical installations of buildings" series of national standard is divided into the following five sections.
--- Part 1. Fundamental principles, assessment of general characteristics and definitions
--- Part 4. Security
--- Part 5. Selection and erection of electrical equipment
--- Part 6. Inspection
Requirements for special installations or locations. --- Part 7
This is Part 713 Part 7 special installations or locations requirements.
This section identical with IEC 60364-7-713.1996 (first edition) "Electrical installations of buildings - Part 7. Special installations or locations
Requirements Section 713. Furniture "(in English).
This part of IEC 60364-7-713.1996 on the same technical content, but contains the following editorial changes.
a) the decimal symbol instead of using decimal notation ",". ",";
b) using the "part" instead of the "standard";
c) by deleting the IEC standard "Preface."
This part of the reg number and IEC 60364-7-713.1996 exactly.
This part of the National Standardization Technical Committee of electrical building equipment (SAC/TC205) and focal points.
This section is responsible for drafting unit. electrical machines in Design and Research Institute.
The main drafters of this section. Huang Baosheng, Hexiang Kun, Wang Zengyao.
GB 16895.29-2008/IEC 60364-7-713.1996
Introduction
GB (/ T) of this section 16895 requires that supplement, modify or replace the GB (/ T) 16895 General requirements for the rest of some
content.
Dedicated 7-713 number connected to the later part of the GB (/ T) 16895 corresponding part numbers or terms of numbers.
GB (/ T) of this chapter is not listed in section 16895, section or article, it means that GB (/ T) 16895 corresponding general requirements still apply
use.
GB 16895.29-2008/IEC 60364-7-713.1996
Electrical installations of buildings
Requirements for special installations or locations. Section 7-713
Furniture
713 Furniture
713.1 Overview
713.1.1 Scope
The special requirements of this section apply to electrical devices connected to the furniture (and similar furniture) cabling system.
For example. equipped with lighting, sockets, electrical switches, wiring systems and other electrical equipment, beds, cabinets, tables and shop display cabinets.
Requirements of this section apply to fixed wiring is connected to the electrical installations of buildings furniture, also applies to the finished furniture and plugs
Power outlet furniture, furniture unless otherwise specified in other national standards.
Electrical equipment should be connected to the furniture within no more than 240V single-phase power lines, the total load current shall not exceed 16A.
These requirements do not apply to other countries specifically designed for installation in furniture in the standards set forth in the electrical appliances and electrical equipment, for example,
Such as. the furniture packed in easy connection to radios, televisions, refrigerators and electrical installations of buildings bench by plug and socket. In some
A special place, you may need to meet other special requirements.
713.1.2 Normative references
The following documents contain provisions which, through reference to "Electrical installations of buildings" in this text, constitute provisions of this section. For dated
Reference documents, after its release date of all of the amendments (not including errata content) or revisions do not apply to this section; however, encourage and
This part of the agreement if the parties to study the latest versions of these documents. For undated reference documents, the most
The new version applies to this section.
GB 4208-2008 housing protection (IP Code) (IEC 60529.2001, IDT)
GB/T 5013.1-2008 rated voltage of 450/750V and below rubber insulated cables - Part 1. General requirements
(IEC 60245-1.2003, IDT)
GB/T 5013.4-2008 rated voltage of 450/750V and below rubber insulated cables Part 4. Cords and flexible cables
(IEC 60245-4.2003, IDT)
GB/T 5023.3-2008 rated voltage of 450/750V and below PVC insulated cables - Part 3. No fixed wiring
Sheathed cables (IEC 60227-3.1997, IDT)
GB/T 5023.5-2008 rated voltage of 450/750V and below PVC insulated cables Part 5. Flexible cables (cords)
(IEC 60227-5.2003, IDT)
GB/T 5169.11-2006 Fire hazard testing for electric and electronic products - Test methods refined glow-wire test and guidance
(IEC 60695-2-10.2000, IDT)
GB 7000.1-2007 Lamps - Part 1. General requirements and tests (IEC 60598-1.2003, IDT)
GB/T 12706-2002 rated voltage 1kV (Um = 1.2kV) ~ 35kV (Um = 40.5kV) extruded insulation power cables and
Accessories (eqv IEC 60502.1997)
GB 16895.1-2008 Electrical installations of buildings - Part 1. Fundamental principles, assessment of general characteristics and definitions (IEC 60364-1.
2005, IDT)
Part 5 GB 16895.6-2000 Electrical installations of buildings. Selection and erection of electrical equipment - Chapter 52. Wiring systems
(Idt IEC 60364-5-52.1993)
GB/T 16895.9-2000 Part 7 Electrical installations of buildings. Requirements for special installations or locations - Section 707. Data at
GB 16895.29-2008/IEC 60364-7-713.1996
Processing equipment electrical equipment grounding requirements (idt IEC 60364-7-707. 1984)
Section 7 GB 16895.13-2002 Electrical installations of buildings. Requirements for special installations or locations - Section 701. equipped with a bathtub
Or electrical devices shower basin locations (idt IEC 60364-7-701. 1984)
Part 5 GB/T 16895.15-2002 Electrical installations of buildings. Selection and erection of electrical equipment - Section 523. Wiring systems
Ampacity (idt IEC 60364-5-523. 1989)
Part 5 GB/T 16895.18-2002 Electrical installations of buildings. Selection and erection of electrical equipment - Chapter 51. Common rules
(Idt IEC 60364-5-51.1997)
Part 5 GB 16895.20-2003 Electrical installations of buildings. Selection and erection of electrical equipment Chapter 55. Other equipment lines
EC Section 551. Low-voltage power equipment (IEC 60364-5-551.1994, IDT)
GB 17466-1998 General requirements for household and similar fixed electrical installations of electrical accessories housing (eqv IEC 60670.
1989)
713.1.3 definitions
713.1.3.1
Items for work or leisure activities in the domestic, commercial and industrial properties in movable or fixed, such as desks, chairs, tables and work
Workbench, cabinets and beds.
Selection and installation of electrical equipment 713.5
713.51 General rules
Electrical equipment and accessories for furniture cabling system should be selected and installed in accordance with environmental conditions, particularly in the mechanical stress and fire risk
Insurance aspects.
713.52 cabling system
Connection 713.52.1 fixed electrical installations of buildings and furniture between.
Connecting the fixed electrical installations and building wiring between the furniture should be a fixed connection or plug and socket connection.
Select 713.52.2 cabling system
Furniture, electrical devices connected to the wiring system should meet the following requirements.
a) If a fixed connection should be selected in line with GB/T 12706-2002, GB/T 5023.3-2008 or GB/T 5013.1-
2008 rigid cable;
b) If a plug and socket connection should be selected in line with GB/T 5013.4-2008 rubber insulated flexible cables and cords or multi-core character
Flexible multi-core cables and cords together GB 5023.5-2008 PVC insulated.
Any line may move within the furniture should be consistent with GB/T 5013.4-2008 or GB/T 5023.5-2008 flexible cable
Multi-core cord.
Conductor cross-section 713.52.3
Conductor should be copper, and the section is not less than 1.5mm2.
If you do not supply power to the outlet and whose length does not exceed 10m, copper core cross section flexible cables and cords can be reduced to 0.75mm2.
Installation 713.52.4 cabling system
Cables and cords should be properly against mechanical damage. They should be securely placed on the furniture or in the manufacture of furniture to do the cable guide
Pipe, cable tray, cable ducts or cable trench.
Cables and cords should prevent tension or torsion. Furniture and entering at the junction near the device should be fitted to reduce the stress.
Select 713.52.5 Annex
Accessory wiring system should be consistent with GB concealed Junction Box 17466-1998 requirements, including.
--- High mechanical strength;
--- Annex should be fixed on the furniture;
--- In line with GB/T 5169.11-2006 heat resistance (850 ℃ glow wire test);
GB 16895.29-2008/IEC 60364-7-713.1996
--- In line with GB 4208-2008 level of IP3X protective housing to prevent foreign matter from entering the solid.
713.55 Other equipment
713.55.1 lamps and other electrical equipment
Lighting equipment and other provisions shall 713.55.1.1 to 713.55.1.3 selection and installation.
713.55.1.1 lamp housings and other equipment to reach the maximum temperature shall not exceed the following values.
--- Normal operation 90 ℃; and
Under fault conditions --- 115 ℃.
In addition, it must comply with the provisions within the manufacturer's instructions on the installation location and safe distance from the combustible portion.
713.55.1.2 If the lamp structure does not prevent the use of excessive wattage bulbs, above or below in furniture lamps shall be marked with the lamp
The maximum wattage allowed.
713.55.1.3 When electrical equipment prone to the heat may cause ignition temperature in the enclosed space, should be installed by the door shut
Closing control switch that allows reliably disconnecting the machine when the door is closed. This is the case for example, lamps installed in the folding bed.
GB 16895.29-2008/IEC 60364-7-713.1996
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB 16895.29-2008_English be delivered?Answer: Upon your order, we will start to translate GB 16895.29-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB 16895.29-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB 16895.29-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|