GB/T 16895.24-2024: Low-voltage electrical installations - Part 7-710: Requirements for special installations or locations - Medical locations
Status: Valid

GB/T 16895.24: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 16895.24-2024English604 Add to Cart 5 days [Need to translate] Low-voltage electrical installations - Part 7-710: Requirements for special installations or locations - Medical locations Valid GB/T 16895.24-2024
GB 16895.24-2005English539 Add to Cart 3 days [Need to translate] [GB/T 16895.24-2005] Electrical installations of buildings -- Part 7-710: Requirements for special installations or locations -- Medical locations Valid GB 16895.24-2005

PDF similar to GB/T 16895.24-2024


Standard similar to GB/T 16895.24-2024

GB/T 17285   GB/T 17045   GB/T 16842   GB/T 16895.25   GB/T 16895.22   GB/T 16895.33   

Basic data

Standard ID GB/T 16895.24-2024 (GB/T16895.24-2024)
Description (Translated English) Low-voltage electrical installations - Part 7-710: Requirements for special installations or locations - Medical locations
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K09;P63
Classification of International Standard 29.020; 91.140.50
Word Count Estimation 30,357
Date of Issue 2024-10-26
Date of Implementation 2025-05-01
Older Standard (superseded by this standard) GB/T 16895.24-2005
Issuing agency(ies) State Administration for Market Regulation, China National Standardization Administration

GB/T 16895.24-2024: Low-voltage electrical installations - Part 7-710: Requirements for special installations or locations - Medical locations


---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT16895.24-2024
ICS 29.020;91.140.50 CCSK09;P63 National Standard of the People's Republic of China Replaces GB/T 16895.24-2005 Low-voltage electrical equipment Part 7-710.Requirements for special installations or locations medical facilities (IEC 60364-7-710.2021, IDT) Released on October 26, 2024, implemented on May 1, 2025 State Administration for Market Regulation The National Standardization Administration issued

Table of Contents

Preface III Introduction V 710 Medical facilities 1 710.1 Scope 1 710.2 Normative references 1 710.3 Terms and Definitions 2 710.30 Evaluation of general characteristics 4 710.31 Purpose, power supply and structure 4 710.41 Safety protection --- protection against electric shock 5 710.42 Safety protection --- thermal effect protection 7 710.44 Safety protection --- voltage disturbance and electromagnetic disturbance protection 7 710.51 Selection and installation of electrical equipment---General rules 7 710.52 Selection and installation of electrical equipment---wiring systems 9 710.53 Selection and installation of electrical equipment - isolation, switching, control, monitoring and safety protection devices 9 710.55 Selection and installation of electrical equipment---other equipment 10 710.56 Selection and installation of electrical equipment --- safety features 11 710.6 Test 13 Appendix A (Informative) Example of Classification and Level of Safety Facilities in Medical Facilities 15 Appendix B (Informative) Guidelines for Electromagnetic Interference (EMI) 16 Appendix C (Informative) List of Notes for Certain Countries 17 Reference 23 Preface This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1.Structure and drafting rules for standardization documents" Drafting. GB/T 16895 "Low Voltage Electrical Installations" has been published in 6 parts, of which Part 4, Part 5, Part 7 and Part 8 are divided into For multiple subsections. --- Part 1.Basic principles, general characteristics evaluation and definitions; --- Part 4.Safety protection; --- Part 5.Selection and installation of electrical equipment; --- Part 6.Inspection; --- Part 7.Requirements for special installations or locations; --- Part 8.Functional aspects. This document is subpart 7-710 of GB/T 16895.The following subparts have been published for part 7 of GB/T 16895. --- Low-voltage electrical installations Part 7-701.Requirements for special installations or locations - Locations with bathtubs or showers; --- Low voltage electrical installations Part 7-702.Requirements for special installations or locations Swimming pools and fountains; --- Electrical installations of buildings - Part 7-703.Requirements for special installations or locations - Rooms and cubicles equipped with sauna heaters; --- Low-voltage electrical installations Part 7-704.Requirements for special installations or locations Electrical installations in construction and demolition locations; --- Low voltage electrical installations Part 7-705.Requirements for special installations or locations Agricultural and horticultural facilities; --- Low voltage electrical installations Part 7-706.Requirements for special installations or locations Conductive locations with restricted activities; --- Low voltage electrical installations Part 7-710.Requirements for special installations or locations Medical locations; --- Low voltage electrical installations Part 7-711.Requirements for special installations or locations Exhibitions, displays and exhibition areas; --- Low voltage electrical installations Part 7-712.Requirements for special installations or locations Solar photovoltaic (PV) power supply systems; --- Electrical installations in buildings - Part 7-713.Requirements for special installations or locations - Furniture; --- Low voltage electrical installations Part 7-714.Requirements for special installations or locations Outdoor lighting installations; --- Electrical installations in buildings - Part 7-715.Requirements for special installations or locations - Extra-low voltage lighting devices; --- Electrical installations in buildings Part 7-717.Requirements for mobile or transportable units for special installations or locations; --- Low voltage electrical installations Part 7-722.Requirements for special installations or locations Electric vehicle power supply; --- Electrical installations in buildings Part 7-740.Requirements for special installations or locations Structures in amusement parks and circuses, entertainment facilities and sheds; --- Part 7-753.Requirements for special installations or locations. Heating cables and embedded heating systems. This document replaces GB/T 16895.24-2005 "Electrical installations of buildings - Part 7-710.Requirements for special installations or locations" Compared with GB/T 16895.24-2005, in addition to structural adjustments and editorial changes, the main technical changes are as follows. --- Changed the scope of application (see 710.1, 710.1 of the.2005 edition); --- Changed the terms "medical places", "patients", "medical electrical equipment", "applied parts", "medical electrical systems", "patient environment", "class 0 places" Terms and definitions for "medical IT system", "main distribution panel", "category 1 location", "category 2 location", "medical IT system", and "main distribution panel" (see 710.3.1 to 710.3.11, 2005 edition, 710.3.1 to 710.3.11); --- Added the terms and definitions of "safety facility power supply", "medical insulation monitor", "insulation fault location system" and "uninterruptible power supply" (See 710.3.12, 710.3.13, 710.3.14, 710.3.15); --- Added purpose, power supply and structure (see 710.31); --- Increased safety protection --- electric shock protection (see 710.41); --- Changed 710.413 to 710.411 (see 710.411, 710.413 of the.2005 edition); --- Increased requirements for insulation fault location systems (see 710.411.6.3.101); --- Changed the protection against fire caused by electrical equipment, including arc fault detection devices (see 710.421, 710.422 of the.2005 edition); --- Increased safety protection --- voltage disturbance and electromagnetic disturbance protection (see 710.44); --- Changed the general rules to cover distribution boards and electrical operating areas (see 710.51, 710.51 of the.2005 edition); --- Changed the separate subclauses for diagrams, documents and operating instructions in identification (see 710.514, 710.514.5 of the.2005 edition); --- Added electric shock protection equipment, protection of electrical appliances, isolation and switching, monitoring (see 710.531, 710.535, 710.536, 710.537); --- Changed the selection and installation of electrical equipment --- other equipment (see 710.55, 710.55 of the.2005 edition); --- Added selection and installation of electrical equipment---safety facilities (see 710.56); --- Changed the inspection content (see 710.6, 710.6 of the.2005 edition); --- Deleted level 0.15 of medical facility safety facilities (see Appendix A of the.2005 edition). This document is equivalent to IEC 60364-7-710.2021 "Low-voltage electrical installations - Part 7-710.Requirements for special installations or locations" Treatment Places. Please note that some of the contents of this document may involve patents. The issuing organization of this document does not assume the responsibility for identifying patents. This document is proposed and coordinated by the National Technical Committee for Standardization of Electrical Installations in Buildings (SAC/TC205). This document was drafted by. Beijing Xingdian International Engineering Management Co., Ltd., China Machinery International Engineering Design and Research Institute Co., Ltd., Zhejiang Chint Electric Co., Ltd., China Machinery and Electronics Design and Research Institute Co., Ltd., China Municipal Engineering Northwest Design and Research Institute Co., Ltd., Schneider Electric De Electric (China) Co., Ltd., Siemens (China) Co., Ltd., Schneider Wangao (Tianjin) Electrical Equipment Co., Ltd., Shanghai Architectural Design Institute Co., Ltd., Kunming Architectural Design and Research Institute Co., Ltd., and China Construction Design and Research Institute Co., Ltd. The main drafters of this document are. Jiao Jianlei, Wang Jianhua, Huang Baosheng, Xu Xiaodong, Zhen Zhuo, Qian Zhongyang, Tang Ying, Li Hui, Chen Xiliang, Chen Jiefu, Xi Wei, Zhang Tieming, Liu Zhao, Hou Yubinyu, Hou Shuai, Zhang Chunyan, and Han Zhanqiang. The previous versions of this document and the documents it replaces are as follows. ---First published as GB 16895.24-2005 in.2005, and changed to GB/T 16895.24-2005 in.2017; ---This is the first revision.

introduction

GB/T 16895 (all parts) proposes the safety protection of low-voltage electrical installations in general installations or places and special installations or places, The selection, installation and inspection requirements of electrical equipment have positive guiding significance for the safe use of low-voltage electrical equipment. GB/T 16895 is intended to consist of six parts. --- Part 1.Basic principles, general characteristics evaluation and definitions. The purpose is to provide a basis for the design, installation and inspection of low voltage electrical installations. Establish safety rules to avoid damage to people, livestock and property during the installation and use of low-voltage electrical equipment, and ensure that electrical Correct installation and operation of the device. --- Part 4.Safety protection. Contains 4-41, 4-42, 4-43, 4-44 sub-parts, the purpose is to respectively describe the safety of electrical devices during installation and use. Specific safety protection requirements are put forward for four types of electrical hazards. electric shock, thermal effect, overcurrent, voltage interference and electromagnetic interference. --- Part 5.Selection and installation of electrical equipment. Contains 5-51, 5-52, 5-53, 5-54, 5-55, 5-56, 5-57 subparts, purpose It is a wiring system that is used for safety protection, isolation, switching, control and monitoring of electrical appliances according to the function of the equipment and the installation environment. Grounding and protective conductors, low-voltage generating equipment, auxiliary equipment, lamps and lighting fixtures, safety devices and stationary batteries Selection and installation required. --- Part 6.Inspection. The purpose is to put forward specific requirements for the initial inspection and periodic inspection of electrical installations to ensure the long-term safe operation of the equipment. Provide quality assurance. --- Part 7.Requirements for special installations or locations. Contains 7-701, 7-702, 7-703, 7-704, 7-705, 7-706, 7-710, 7-711, Subparts 7-712, 7-713, 7-714, 7-715, 7-717, 7-722, 7-740, and 7-753 are intended to address specific requirements for various types of special installations or locations. The various sub-parts of Part 7 are relatively independent and have no direct connection with each other. --- Part 8.Functional aspects. Contains subparts 8-81, 8-82, and 8-83.The purpose is to describe the functional aspects of electrical equipment during design, installation, and operation. It proposes requirements, recommendations and methods for the assessment of energy efficiency (EE), defines prosumer distribution equipment and specifies its operating modes. The above-mentioned Parts 1, 4, 5 and 6 are general parts (general parts), most of which are applicable to Part 7. Some specific requirements in this document supplement, modify or replace certain requirements of the general part of GB/T 16895 that are valid at the time of publication of this document. The absence of any exclusions from these general terms and conditions means that these general terms and conditions apply (undated references). These requirements have been replaced by those still in force at the time of publication of this document. The numbering of clauses in this document follows the pattern of GB/T 16895 and the corresponding referenced documents. The number following the specific number of this document is The number of the clause in the corresponding part or other parts of GB/T 16895.In addition to the requirements or explanations of other parts of GB/T 16895, such as If additional requirements or explanations are needed, the clauses are numbered as 710.101, 710.102, 710.103, etc. If the revision of the general part is updated or modified after the publication of this document, the general part number mentioned in this document shall be updated or modified. The clause numbers may no longer correspond to the latest edition of the General Part. Please pay attention to the version numbers of the referenced documents. The particular requirements of this document apply to electrical installations in medical locations. In medical settings, patients may be exposed to the effects of medical electrical (ME) equipment. Safety measures for staff. a) The body impedance is reduced due to frequent cuts or breaks in the skin; b) risks associated with loss of power, particularly to life-support equipment; c) Increased risk of electric shock due to the presence of fluids such as blood, saline, and water (e.g. for irrigation). a) and b) affect patients, while c) affects both patients and healthcare professionals. For every activity and function in a healthcare setting, there are specific safety requirements to consider, including protection against electric shock and continuity of power supply. Safety can be achieved by applying the safe operation and maintenance requirements of medical electrical equipment in this document. Low-voltage electrical equipment Part 7-710.Requirements for special installations or locations medical facilities 710 Medical Facilities 710.1 Scope The specific requirements of this document apply to electrical installations in medical settings to ensure the safety of patients and medical personnel. These requirements are aimed at. --- Hospitals, clinics or similar institutions (including similar transportable and mobile places); At the same time, after evaluation according to 710.30, it may also include. --- Nursing homes and health clinics; --- Dedicated places for patients in nursing homes and elderly care centers to receive medical care; ---Medical centers, outpatient clinics (departments), emergency rooms; ---Other outpatient institutions (industrial, sports and other); ---Internal medicine and dentistry clinics; ---Infirmary at the workplace; --- Other places where medical equipment is used; ---Veterinary clinic; ---Utilize existing facilities and convert them into rooms for medical use. This list is not exhaustive. The requirements of this document do not apply to medical (diagnostic) electrical equipment and medical (diagnostic) electrical system products. NOTE. IEC 60601 (all parts) covers medical electrical equipment and medical electrical system products. 710.2 Normative references The contents of the following documents constitute the essential clauses of this document through normative references in this document. For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to This document. GB/T 16895.1-2008 Low voltage electrical installations Part 1.Basic principles, general characteristics, evaluation and definitions (IEC 60364-1. 2005, IDT) GB/T 16895.2-2017 Low-voltage electrical installations Part 4-42.Safety protection against thermal effects (IEC 60364-4-42. 2010, IDT) GB/T 16895.6-2014 Low-voltage electrical installations Part 5-52.Selection and installation of wiring systems for electrical equipment (IEC 60364-5-52.2009, IDT) GB/T 16895.10-2021 Low-voltage electrical installations Part 4-44.Protection against voltage disturbances and electromagnetic disturbances (IEC 60364-4-44.2007 IEC 60364-4-44.2007/AMD1.2015 IEC 60364-4-44.2007/AMD2.2018,IDT) GB/T 16895.18-2010 Electrical installations of buildings Part 5-51.General rules for selection and installation of electrical equipment (IEC 60364-5-51.2005, IDT) GB/T 16895.21-2020 Low-voltage electrical installations Part 4-41 Safety Protection Protection against electric shock (IEC 60364-4-41. 2017, IDT) GB/T 16895.22-2022 Low voltage electrical installations Part 5-53.Selection and installation of electrical equipment for safety protection, isolation Electrical appliances for disconnection, switching, control and monitoring (IEC 60364-5-53.2020, MOD) Note. There is no technical difference between the content cited in GB/T 16895.22-2022 and the content cited in IEC 60364-5-53.2020.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 16895.24-2024_English be delivered?

Answer: Upon your order, we will start to translate GB/T 16895.24-2024_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 16895.24-2024_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 16895.24-2024_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 16895.24-2024?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 16895.24-2024 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.