GB 1588-2024: Medical glass thermometer
Status: Valid

GB 1588: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB 1588-2024English359 Add to Cart 4 days [Need to translate] Medical glass thermometer Valid GB 1588-2024
GB 1588-2001English339 Add to Cart 3 days [Need to translate] Clinical thermometer Valid GB 1588-2001
GB 1588-1989English399 Add to Cart 3 days [Need to translate] Clinical thermometer Obsolete GB 1588-1989

PDF similar to GB 1588-2024


Standard similar to GB 1588-2024

YY/T 1712   GB 9706.227   YY/T 1519   GB/T 21417.1   GB/T 21416   

Basic data

Standard ID GB 1588-2024 (GB1588-2024)
Description (Translated English) Medical glass thermometer
Sector / Industry National Standard
Classification of Chinese Standard C38
Classification of International Standard 11.040.55
Word Count Estimation 18,155
Date of Issue 2024-04-29
Date of Implementation 2026-05-01
Older Standard (superseded by this standard) GB 1588-2001
Issuing agency(ies) State Administration for Market Regulation, China National Standardization Administration

GB 1588-2024: Medical glass thermometer

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS 11:040:55 CCSC38 National Standards of People's Republic of China Replaces GB 1588-2001 Medical glass thermometer Released on 2024-04-29 2026-05-01 implementation State Administration for Market Regulation The National Standardization Administration issued

Table of Contents

Preface III 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 Requirements 1 5 Test methods 6 6 Cycle Inspection 8 7 Markings, Instructions for Use 9

Foreword

This document is in accordance with the provisions of GB/T 1:1-2020 "Guidelines for standardization work Part 1: Structure and drafting rules for standardization documents" Drafting: This document replaces GB 1588-2001 "Glass Thermometers": Compared with GB 1588-2001, except for structural adjustments and editorial changes, In addition, the main technical changes are as follows: --- Changed the scope of application of the standard (see Chapter 1, Chapter 1 of the:2001 edition); --- Deleted the contents of anus (veterinary) and neonatal rod type, and adjusted the requirements for measurement sites (see 4:1:1, 3:1 of the:2001 edition); --- Changed the requirements for basic dimensions (see 4:1:2, 4:1 of the:2001 edition); --- Changed the stress requirements (see 4:2:8, 4:10 of the:2001 edition); --- Unified the requirements for the width of the glaze band of glass tubes (see 4:2:9, 4:2:4 of the:2001 edition); --- Changed the requirements for scale plates (see 4:4, 4:7 of the:2001 edition); --- Changed the requirements for the width of the scale lines of the rod-type glass thermometer (see 4:6:2, 4:9:2 of the:2001 edition); --- The test method for bubbles has been changed (see 5:3, 5:5:2 of the:2001 edition); --- Changed the test method for the difficulty of temperature-sensitive liquid column to be thrown off (see 5:4:4, 5:14 of the:2001 edition); --- Deleted the content of batch inspection (see 6:2 of the:2001 edition); --- Changed the sampling plan for periodic inspection of indications (see 6:3, 6:3:3 of the:2001 edition); --- Deleted the contents of packaging, transportation and storage (see Chapter 8 of the:2001 edition); --- Deleted the content of quality assurance (see Chapter 9 of the:2001 edition): Please note that some of the contents of this document may involve patents: The issuing organization of this document does not assume the responsibility for identifying patents: This document is proposed and coordinated by the State Food and Drug Administration: The previous versions of this document and the documents it replaces are as follows: ---First issued as GB 1588-1979 in 1979, first revised in 1989, second revised in:2001; ---This is the third revision: Medical glass thermometer

1 Scope

This document specifies the requirements, inspection rules, marking, instructions for use of medical glass thermometers and describes the corresponding test methods: This document is applicable to medical glass thermometers (hereinafter referred to as "glass thermometers") for measuring human body temperature, with a temperature measurement point structure and a temperature sensing medium of liquid: It is called a glass thermometer):

2 Normative references

The contents of the following documents constitute the essential clauses of this document through normative references in this document: For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to This document: GB/T 2829 Periodic inspection sampling procedures and tables (applicable to the inspection of process stability)

3 Terms and definitions

The following terms and definitions apply to this document: 3:1 scaleline Lines engraved on a glass rod or scale to indicate temperature values: Note: Also called scale line: 3:2 Scale plate Internal standard glass thermometer is a straight, colored (such as milky white) sheet with scale lines, scale values and other symbols printed inside: Note: Also called scale plate: 3:3 The phenomenon that the temperature-sensing liquid column of a glass thermometer automatically retreats toward the temperature-sensing bulb above the retention point structure: Note: It indicates the stability of the indication of glass thermometer within a certain period of time: 3:4 The phenomenon that the temperature-sensing liquid column of a glass thermometer is difficult to retract under a certain external force: 3:5 Interrupt liquid column The liquid column of the glass thermometer is disconnected above the retention point structure:

4 Requirements

4:1 Type 4:1:1 The type and measuring range of glass thermometers shall comply with the requirements of Table 1:

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB 1588-2024_English be delivered?

Answer: Upon your order, we will start to translate GB 1588-2024_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB 1588-2024_English with my colleagues?

Answer: Yes. The purchased PDF of GB 1588-2024_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB 1588-2024?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 1588-2024 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.