US$319.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 14048.8-2016: Low-voltage switchgear and controlgear -- Part 7-2: Ancillary equipment -- Protective conductor terminal blocks for copper conductors Status: Valid GB/T 14048.8: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 14048.8-2016 | English | 319 |
Add to Cart
|
3 days [Need to translate]
|
Low-voltage switchgear and controlgear -- Part 7-2: Ancillary equipment -- Protective conductor terminal blocks for copper conductors
| Valid |
GB/T 14048.8-2016
|
| GB/T 14048.8-2006 | English | 599 |
Add to Cart
|
3 days [Need to translate]
|
Low-voltage switchgear and controlgear -- Part 7-2: Ancillary equipment -- Protective conductor terminal blocks for copper conductors
| Obsolete |
GB/T 14048.8-2006
|
| GB 14048.8-1998 | English | 559 |
Add to Cart
|
4 days [Need to translate]
|
Low-voltage switchgear and controlgear. Ancillary equipment. Section 2: Protective conductor terminal blocks for copper conductors
| Obsolete |
GB 14048.8-1998
|
PDF similar to GB/T 14048.8-2016
Basic data | Standard ID | GB/T 14048.8-2016 (GB/T14048.8-2016) | | Description (Translated English) | Low-voltage switchgear and controlgear -- Part 7-2: Ancillary equipment -- Protective conductor terminal blocks for copper conductors | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | K30 | | Classification of International Standard | 29.130.20 | | Word Count Estimation | 16,180 | | Date of Issue | 2016-04-25 | | Date of Implementation | 2016-11-01 | | Older Standard (superseded by this standard) | GB/T 14048.8-2006 | | Quoted Standard | GB 7251.1-2013; GB 14048.1-2012; GB/T 14048.7-2016; GB/T 19334-2003 | | Adopted Standard | IEC 60947-7-2-2009 | | Regulation (derived from) | National Standard Announcement No | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the requirements for protective conductor terminal blocks for screw-type or non-threaded clamping devices, mainly for industrial use, with a terminal block for PE protection of not more than 120 mm2 (250 kcmil), with PEN protection The terminal block is greater than or equal to 10 mm2 (AWG 8). The protective conductor terminal block is used for the electrical and mechanical connection between the copper conductor and the mounting bracket. This standard is applicable to the protection of prefabricated or non-prefabricated round copper conductors with a cross-sectional area of ??0.2 mm2 to 120 mm2 (AWG 24 kcmil to 250 kcmil) in an AC circuit with a rated voltage not exceeding 1000 V, a frequency up to 1000 Hz and a DC circuit not exceeding 1500 V conductor |
GB/T 14048.8-2016: Low-voltage switchgear and controlgear -- Part 7-2: Ancillary equipment -- Protective conductor terminal blocks for copper conductors ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Low-voltage switchgear and controlgear.Part 7-2. Ancillary equipment.Protective conductor terminal blocks for the
ICS 29.130.20
K30
National Standards of People's Republic of China
Replace GB/T 14048.8-2006
Low voltage switchgear and control equipment
Part 7-2. auxiliary devices for copper conductors
Protection of conductor terminal blocks
Part 7-2. Ancilaryequipment-Protectiveconductorterminal
(IEC 60947-7-2..2009, MOD)
2016-04-25 release.2016-11-01 implementation
General Administration of Quality Supervision, Inspection and Quarantine of the People 's Republic of China
China National Standardization Management Committee released
Directory
Preface I
Basic requirements 1
2 Definition 1
Category 3
4 Features 2
5 Product information 3
6 normal use, installation and transportation conditions 4
Structural requirements and performance requirements
8 Test 5
The maximum short-time withstand current of the mounting rail specified in Appendix A (normative) and the rated heating current of the PEN bus 11
Foreword
GB 14048 "Low-voltage switchgear and control equipment" is divided into the following 21 parts.
- Part 1. General;
- Part 2. Circuit breakers;
- Part 3. switch, isolator, disconnector and fuse combination;
- Part 4-1. Contactors and motor starters Electromechanical contactors and motor starters (including motor protector);
- Part 4-2. Contactors and motor starters - AC semiconductor motor controllers and starters (including soft starters);
- Part 4-3. Contactors and motor starters - AC semiconductor controllers and contactors for non - motor loads;
- Part 5-1 Control circuit Electrical and switching elements Electromechanical control circuit appliances;
- Part 5-2. Control circuit appliances and switching element proximity switches;
- Part 5-3. Control circuit electronics and switching elements - Proximity switches (PDF) with definite function under fault conditions
Claim;
- Part 5-4. Control circuit appliances and switching elements - Evaluation of performance of small capacity contacts - Special tests;
- Part 5-5. Control circuit appliances and switching elements - Electrical emergency braking devices with mechanical latch function;
- Part 5-6. Control circuit appliances and switching elements - DC interface (NAMUR) for proximity sensors and switching amplifiers;
- Part 5-7. Control circuit appliances and switching elements for approaching equipment with analog outputs;
- Part 5-8. Control circuit appliances and switching elements - Three enable switches;
- Part 5-9. Control circuit appliances and switching element flow switches;
- Part 6-1. Multifunctional electrical switchgear;
- Part 6-2. Multifunctional electrical appliances (equipment) control and protection switchgear (equipment) (CPS);
- Part 7-1. Terminal blocks for auxiliary devices for copper conductors;
- Part 7-2. Protective devices - Protection conductors for copper conductors - Terminal blocks;
- Part 7-3. Safety requirements for auxiliary device fuses terminal blocks;
- Part 8. Loaded thermal protection (PTC) control unit for rotating electrical machines.
This section is part 7-2 of the GB 14048 "Low Voltage Switchgear and Controlgear".
This part is drafted in accordance with the rules given in GB/T 1.1-2009.
Replacement of GB/T 14048.8-2006 "Low-voltage switchgear and controlgear - Part 7-2. Supplementary devices for copper conductors
Protection conductor terminal block ". The technical differences between this part and GB/T 14048.8-2006 are.
--- 8.3.3.1 "Clamping parts mechanical strength test" delete paragraph 2 and paragraph 4 of the content;
- 8.4.5 "Temperature rise test" The connection of the conductor in paragraph 4 and the bracket shall be carried out in accordance with Table B.1 (for thread diameter less than or equal to
In the 2.8mm screw-type clamping parts) and GB 14048.1-2006 in Table 4, the torque specified by the manufacturer or the larger
Torque value "to" conductor connection and bracket connection should be in accordance with GB 14048.1-2012 in Table 4 of the tightening torque or
Manufacturer specified higher torque value ";
--- 8.4.6 "Short-time withstand current test" in paragraph 2 "tightening torque according to GB 14048.1-2006 in Table 4 or Appendix B
Table B.1 (for threaded clamps with thread diameters less than or equal to 2.8 mm) or specified by the manufacturer for larger torques
Value "to" tightening torque according to the provisions of Table 4 of GB 14048.1-2012 or the manufacturer specified higher torque value ";
- Delete Appendix B (Normative Appendix). Tightening torque used to verify the mechanical strength of threaded clamps.
This part is modified using IEC 60947-7-2..2009 (version 3.0) "Low-voltage switchgear and controlgear Part 7-2. Auxiliary devices
Pieces of copper conductor to protect the conductor terminal block ".
The technical differences between this section and IEC 60947-7-2..2009 are as follows.
--- according to China's actual, the scope of application increased AC rated voltage 1140V appliances;
--- GB 14048.1-2012 "Low-voltage switchgear and controlgear Part 1. General" (IEC 60947-1..2011,
MOD) instead of the reference document IEC 60947-1..2007;
--- GB/T 14048.7-2016 "Low-voltage switchgear and controlgear - Part 7-1. Connection of auxiliary devices for copper conductors
Terminal block "(IEC 60947-7-1..2009, MOD) instead of reference document IEC 60947-7-1;
--- According to China's environmental and material requirements, supplemented the provisions of the relevant requirements of wet and heat and its test methods;
--- For ease of understanding, note 3 is added to Definition 2.1 "Protective conductor terminal block".
This part is made by China Electrical Equipment Industry Association.
This part of the national low-voltage electrical appliances Standardization Technical Committee (SAC/TC189) centralized.
This part is responsible for the drafting unit. Shanghai Electric Research Institute.
This part participates in the drafting unit. Weidmüller Electric (Shanghai) Co., Ltd., Phoenix China Investment Co., Ltd., Shanghai Electric Appliance
Equipment testing.
The main drafters of this part. Zhang Lili, Huang Jingye, Wu Qingyun, Wang Chengping, Zhu Shiming, Sun Jinfeng.
This part of the previous version of the standard to replace the release of the situation.
--- GB 14048.8-1998, GB/T 14048.8-2006.
Low voltage switchgear and control equipment
Part 7-2. auxiliary devices for copper conductors
Protection of conductor terminal blocks
1 basic requirements
1.1 Scope
This part of GB 14048 specifies the protection conductor terminal blocks for screw-type or non-threaded clamps that are primarily intended for use in industry.
Request, with PE protection function of the terminal block is not greater than 120mm2 (250kcmil), with PEN protection function of the terminal block
Or equal to 10mm2 (AWG8).
Note. AWG is an abbreviation for "American Wire Gauge".
kcmil = 1000cmil
1cmil = 1 round ear = diameter 1 mil round area
1mil = 1/1000 inch.
The protective conductor terminal block is used for electrical and mechanical connections between the copper conductor and the mounting bracket.
This part applies to the rated voltage of not more than 1000V1), the frequency of 1000Hz AC circuit and not more than 1500V DC
Circuit with a cross-sectional area of 0.2mm2 ~ 120mm2 (AWG24kcmil ~ 250kcmil) prefabricated or non-preformed copper conductor
The conductor terminal block, the protective conductor terminal block, and the terminal block specified in GB/T 14048.7-2016 are normally used together.
1) AC rated voltage 1140V electrical appliances can refer to this part of the implementation. The requirements for electrical performance and other requirements are determined by the manufacturer and the user.
The following products may use this section as a guide.
- the need to install a special device on the conductor to protect the conductor terminal block, such as quick connect end or connection connection;
- through the edge or tip piercing the insulation to achieve direct contact with the conductor conductor terminal block, such as insulation transfer even
And so on.
When quoting GB 14048.1-2012, this section substitutes the term "clamping part" instead of "terminal".
1.2 Normative references
The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article
Pieces. For undated references, the latest edition (including all modifications) applies to this document.
GB 7251.1-2013 Low voltage switchgear and controlgear - Part 1. General (IEC 61439-1..2011, IDT)
GB 14048.1-2012 Low - voltage switchgear and controlgear - Part 1. General (IEC 60947-1..2011, MOD)
GB/T 14048.7-2016 Low voltage switchgear and controlgear - Part 7-1. Secondary devices - Terminal blocks for copper conductors
(IEC 60947-7-1..2009, MOD)
GB/T 19334-2003 The size of low-voltage switchgear and control equipment in the complete sets of switchgear and control equipment for electrical equipment
Standard mounting rail for rail support (IEC 60715. 1981, IDT)
2 definition
The following terms and definitions, as defined in GB/T 14048.7-2016 and the following terms and definitions, apply to this document.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 14048.8-2016_English be delivered?Answer: Upon your order, we will start to translate GB/T 14048.8-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 14048.8-2016_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 14048.8-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 14048.8-2016?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 14048.8-2016 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|