HOME   Cart(3)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (25 Oct 2025)

GB 10010-2009 English PDF

US$209.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB 10010-2009: [GB/T 10010-2009] Plasticized polyvinyl chloride (PVC) tubing for medical uses
Status: Valid

GB 10010: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB 10010-2009English209 Add to Cart 3 days [Need to translate] [GB/T 10010-2009] Plasticized polyvinyl chloride (PVC) tubing for medical uses Valid GB 10010-2009
GB 10010-1988English439 Add to Cart 4 days [Need to translate] Plasticized polyvinyl chloride (PVC) tubing for medical uses Obsolete GB 10010-1988

PDF similar to GB 10010-2009


Standard similar to GB 10010-2009

GB/T 10006   GB/T 10003   GB/T 10004   GB/T 10002.2   GB/T 10002.1   

Basic data

Standard ID GB 10010-2009 (GB10010-2009)
Description (Translated English) [GB/T 10010-2009] Plasticized polyvinyl chloride (PVC) tubing for medical uses
Sector / Industry National Standard
Classification of Chinese Standard G33
Classification of International Standard 83.140.40; 11.040.30
Word Count Estimation 8,824
Date of Issue 2009-09-30
Date of Implementation 2010-06-01
Older Standard (superseded by this standard) GB 10010-1988
Quoted Standard GB/T 191; GB/T 1040.2-2006; GB/T 2411; GB/T 2828.1-2003; GB/T 4615-2008; GB/T 14233.1-1998; GB/T 16886.1
Regulation (derived from) Announcement of Newly Approved National Standards No. 10 of 2009 (No. 150 overall)
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This Chinese standard specifies the requirements for medical soft PVC tubing, test methods, inspection rules, marking, packaging, transport and storage. This standard applies to PVC resin as the main raw materials in medical-related fields, for conveying fluid medium gas, liquid (such as blood, liquid, nutrition, waste liquids, etc.), Shore (A) Hard in the range of 40 to 90 PVC pipe (hereinafter referred to as pipes).

GB 10010-2009: [GB/T 10010-2009] Plasticized polyvinyl chloride (PVC) tubing for medical uses

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Plasticized polyvinyl chloride (PVC) tubing for medical uses ICS 83.140.40; 11.040.30 G33 National Standards of People's Republic of China Replacing GB 10010-1988 Medical soft polyvinyl chloride pipe Published 2009-09-30 2010-06-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China issued

Foreword

3.4, 3.5 of this standard is mandatory, the rest are recommended. This standard replaces GB 10010-1988 "soft PVC medical tubing." This standard GB 10010-1988 The main difference is as follows. --- Removed steam resistance, resistance to dry heat, low temperature performance, density, water absorption, hydrostatic testing, permanent deformation; --- remove chemical properties of the ether-soluble extract zinc content. This standard chemical properties of the pharmaceutical industry standard reference project YY1048-2007 "artificial heart-lung machine during cardiopulmonary bypass pipeline." The standard proposed by China Light Industry Federation. This standard by the National Standardization Technical Committee of plastic products. This standard is drafted. Tianjin Plastics Research Institute. Participated in the drafting of this standard. Kyle Yangzhou Chemical Co., Ltd., Guangdong Sheng Hengchang Chemical Industry Co., Ltd., Jiang Su Kaishou medical equipment Limited. The main drafters. Cao often, horsepower, Qiang Xuan, summer sleeve China, Luo Chong far, Heng Jianhua. This standard supersedes the previous editions are. --- GB 10010-1988. Medical soft polyvinyl chloride pipe Range 1 This standard specifies the requirements of soft PVC medical tubing, test methods, inspection rules, marking, packaging, transportation and storage. This standard applies to a polyvinyl chloride resin as the main raw material, in the relevant medical art, --- for conveying a gas, a liquid (e.g., flowable medium Blood, liquid, nutrient solution, liquid excreta, etc.), Shore (A) hardness in the range of 40 to 90 PVC pipe (hereinafter referred to as pipes).

2 Normative references

Terms of the following documents become provisions of this standard by reference in this standard. For dated reference documents, all later Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to agreements based on this standard Whether the latest versions of these documents. For undated references, the latest version applies to this standard. GB/T 191 Packaging Pictorial flag (GB/T 191-2008, ISO 780.1997, MOD) GB /Plastics Determination of tensile properties T 1040.2-2006 Part 2. Test conditions for molding and extrusion plastics (ISO 527-2. 1993, IDT) GB/T 2411 plastic and hard rubber hardness measured indentation hardness (Shore hardness) (GB/T 2411-2008, ISO 868. 2003, IDT) GB/T 2828.1-2003 Sampling procedures - Part 1. Test batches by sampling the reception quality limit (the AQL) search Plan (ISO 2859-1.1999, IDT) GB/T 4615-2008 residual vinyl chloride monomer content by gas chromatography (ISO 6401. 1985, NEQ) GB/T 14233.1-1998 medical infusion, transfusion, injection equipment methods - Part 1. Method for chemical analysis Biological Evaluation GB/T 16886.1 medical devices - Part 1. Evaluation and Testing (GB/T 16886.1-2001, idt ISO 10993- 1.1997) 3.1 Size Pipe size specifications agreed upon by both parties, the limit deviation shall be as specified in Table 1. Table 1 limit deviations pipe Project limit deviation Outside diameter the inside diameter of Wall thickness ± 15% Length of ± 5% Note. There are special requirements, agreed upon by both supply and demand. 3.2 Sensory Plasticized tubing should be good, the same smell, no bubbles, no kink, deformation, the inner and outer wall should be smooth and clean, pollution-free. 3.3 Physical and mechanical properties Physical and mechanical properties of the pipe should be in accordance with Table 2. Table 2. Physical and Mechanical Properties Item Index Tensile strength/MPa ≥12.4 Tensile strain at break /% ≥300 Compression set /% ≤40 Shore (A) hardness N ± 3 NOTE. Different different Shore hardness pipe required, N is the nominal pipe Shore (A) hardness. 3.4 Chemical properties 3.4.1 reducing substances The difference between the volume of the test liquid with the potassium permanganate solution 20mL same batch consumed blank solution [Ba (KMnO4) = 0.002mol/L] of No more than 1.5mL. 3.4.2 heavy metal The total content of heavy metals in the test liquid shall not exceed 1.0μg/mL, cadmium, tin should not be detected. 3.4.3 pH Comparative test liquid and blank solution, the pH value of the difference may not exceed 1.0. 3.4.4 evaporation residue 50mL total evaporation residue test liquid should not exceed 2.0mg. 3.4.5 vinyl chloride monomer Vinyl chloride monomer content should be less than 1.0μg/g. 3.5 biological properties Biological properties of the pipe should meet the requirements of the appropriate biological evaluation of the country. Test Method 4 4.1 Pipe Size and limit deviations The outer diameter of the pipe, the inner diameter, wall thickness or projector using precision instruments to measure not less than 0.01mm, and the length is 1mm with indexing Gage measurements. 4.2 Sensory Check in indoor natural light. 4.3 Physical and mechanical properties 4.3.1 Environment for conditioning and testing Sample shall be (23 ± 2) ℃, 45% relative humidity environment of 55% for at least 4h, and tested under these conditions. 4.3.2 tensile strength, tensile strain at break 8mm diameter is smaller than or equal to the pipe, the pipe taken directly to the test, the total length of the sample is 120mm, the effective length of 50mm; inner diameter Pipe greater than 8mm, using GB/T 1040.2-2006 A. FIG. 5A specimen type 2; test speed of 100mm/min, the remaining press GB/T 1040.2-2006 provisions. 4.3.3 Compression set 4.3.3.1 appliances Splints, pads, not less than 0.02mm vernier caliper. 4.3.3.2 Sample Sample groups of three sections, each 50mm. 4.3.3.3 Test procedure The outer diameter of the measurement specimen, the specimen is clamped in the clamp pad having a thickness of one-half the outer diameter of the spacer is allowed to stand at 23 ℃ ± 2 ℃ environment 24h, remove the sample, placed IH, measuring the outer diameter direction of compression, calculated according to formula (1) compression set, the results were the best of the three samples A large value, accurate to 0.1%. Q = D0-D1D0 × 100 (1) Where. Q --- compression set,%; The outer diameter D0 --- pressure before the sample in millimeters (mm); After compression direction Dl --- pressed sample diameter, in millimeters (mm). 4.3.4 Shore 4.3.4.1 Sample Preparation After mixing pipe material or pulverized material in the mill and ℃ temperature of (165 ± 5) mixing plastic 5min ~ 10min, and then at a temperature of (165 ± 5) ℃ hydraulic pressure in the press is not preheated, heated and pressurized, the pressing pressure of the order of cooling the mold 15min ~ 20min. Test piece should be flat, the thickness is not less than 5mm. 4.3.4.2 Test procedure Tested according to the provisions of GB/T 2411's. 4.4 Chemical properties 4.4.1 Preparation of test solution A sample was cut into 1cm long segment, into a glass container, and outside the sample by the total surface area (cm2) and the ratio of water (mL) for 2/1 Example add water, capped, placed 24h at 37 ℃ ± 1 ℃, the sample was separated from the liquid, cooled to room temperature, as the test solution. Take the same volume of water in a glass container, with the blank solution was prepared. 4.4.2 reducing substances Tested according to the provisions of GB/T 14233.1-1998 in 5.2.2. 4.4.3 heavy metal The total content of heavy metals tested according to the provisions of GB/T 14233.1-1998 in 5.6.1. In determination of cadmium, tin inspection predetermined GB/T 14233.1-1998 in 5.9.1. 4.4.4 pH Tested according to the provisions of GB/T 14233.1-1998 in 5.4.1. 4.4.5 evaporation residue Tested according to the provisions of GB/T 14233.1-1998 in 5.5. 4.4.6 vinyl chloride monomer Tested according to the provisions of GB/T 4615-2008's. 4.5 biological properties Biological properties were evaluated according to the provisions GB/T 16886.1's.

5 Inspection Rules

5.1 Inspection Classification 5.1.1 factory inspection Sensory factory inspection items, size, tensile strength, tensile strain, (A) Hardness, Shore chemical properties of the reducing substance, The total content of heavy metals, pH. 5.1.2 Type inspection Type test items 3.1 to 3.4, conduct a test every year under normal circumstances. The following circumstances shall be type tested. a) new products or old products to the plant when; B) after formal production, such as raw materials, a larger change process, it may affect product performance; c) Discontinued more than six months to restore production; D) When the factory test results and the last type test results are quite different; e) the national quality supervision agency made when required for type testing. 5.1.3 Biological performance test Under normal circumstances biology test performance test once every four years. One of the following circumstances should be tested biological properties. a) new products or old products to the plant when; B) after the official production, such as raw materials, processes are major changes, it may affect product performance. 5.2 Batching and Sampling 5.2.1 Batch With the same materials, the same specifications of the formulation and production process, from the same batch as a pipe, each batch does not exceed 20000m, When less than 20000m, continuous 7d pipe produced batch. 5.2.2 Sampling Sensory, size press test GB/T 2828.1-2003 predetermined, normally checked using a sampling program, taking general inspection level Ⅱ, reception quality limit (AQL) 4.0, Table 3 sampling plan. Physical and mechanical properties of the pipe, chemical and biological properties of the test, should be Appearance, size inspection sample a sufficient number of random samples. Table 3 sampling plan in meters Batch range The sample size Receiving a number Ac Rejection number Re 3 ~ 15301 16 to 25,501 26 to 50,812 51 ~ 901312 91 ~ 1502023 151 ~ 2803234 281 ~ 5005056 501 ~ 12008078 1201 ~ 32001251011 3201 ~ 100002001415 10001 ~ 350003152122 5.3 determine the rules Sensory, size determined according to Table 3. Test results Mechanical tubing physical and chemical properties, the items while if it failed, should double the original random sample batch of The project re-inspection, re-inspection results are satisfactory, then this batch of qualified pipe. Biological properties of the pipe when the unqualified items, then this batch Pipe failure. 6 signs, packaging, transportation and storage 6.1 mark Each package bag should have inspection certificate, inspection date and code inspector. It should be product specifications, quantity, nominal hardness, factory batch number, manufacturer name, trademarks and other marks on the inner bag products. Shall be marked on the packaging of the product. a) Product name, model number; b) factory batch number; c) production plant name and address; d) gross weight; e) Volume; F) "Handle with care", "fear wet", "heat intolerance" and the like should meet the requirements shown signs GB/T 191 a. 6.2 Packaging 6.2.1 package Polyethylene film product is appropriate for double-sealed packaging. 6.2.2 packaging The packaging is appropriate carton, quality should not exceed 16kg. 6.3 Transport When handling the product to be handled with care during transport should be sunscreen, anti-rain, anti-stress, and maintain the integrity of the packaging. 6.4 Storage It should be placed in a cool, dry, well-ventilated, non-corrosive gases warehouse storage, away from walls and floor at least 200mm, storage For one year.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB 10010-2009_English be delivered?

Answer: Upon your order, we will start to translate GB 10010-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB 10010-2009_English with my colleagues?

Answer: Yes. The purchased PDF of GB 10010-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB 10010-2009?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 10010-2009 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.