| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GA/T 1190-2014 | English | 359 |
Add to Cart
|
3 days [Need to translate]
|
Guidelines for fire fighting of underground buildings
| Obsolete |
GA/T 1190-2014
|
PDF similar to GA/T 1190-2014
Standard similar to GA/T 1190-2014 GB 4066 GA 578 GB 5135.3 GA/T 998
Basic data | Standard ID | GA/T 1190-2014 (GA/T1190-2014) | | Description (Translated English) | Guidelines for fire fighting of underground buildings | | Sector / Industry | Public Security (Police) Industry Standard (Recommended) | | Classification of Chinese Standard | C83 | | Classification of International Standard | 13.220.10 | | Word Count Estimation | 8,872 | | Quoted Standard | GB 5907; GB/T 11651; GB/T 18664; GA 621 | | Regulation (derived from) | Notice on Publication of Public Safety Industry Standard (Year of 2014); Industry Standard Record Announcement No. 4 of 2015 (No. 184) | | Issuing agency(ies) | Ministry of Public Security | | Summary | This International Standard specifies the terms and definitions, general rules, fire fighting actions and safety of operations of underground fire fighting operations. This standard applies to public security fire brigade underground construction fire fig |
GA/T 1190-2014: Guidelines for fire fighting of underground buildings---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Guidelines for fire fighting of underground buildings
ICS 13.220.10
C83
People's Republic of China Public Security Industry Standards
Underground building fire fighting action guide
Issued on. 2014-09-28
2014-09-28 implementation
People's Republic of China Ministry of Public Security
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard was proposed by the Ministry of Public Security Fire Department.
This standard by the National Standardization Technical Committee fire fighting and rescue Technical Committee (SAC/TC113/SC10) centralized.
This standard is mainly drafted by. Chinese People's Armed Police Force Academy.
This standard participated in the drafting unit. Ministry of Public Security Fire Bureau, Jiangsu Province Public Security Fire Department, Inner Mongolia Autonomous Region Public Security Fire Department, Gansu Province public
Fire Corps.
The main drafters of this standard. Jiang Lianrui, Xiadeng You, Wang Changjiang, given by suppliers, Wang Zhiping, Zhang Qingli, Qi Wenjun, Zhang Zhihui, Weihan Dong,
Gao Ning Yu, Zhu Hui, MING Lixiang Xin, Fan Yingna, Wu Rong, Songshu Yan, Liu Jing.
This standard is the first release.
Underground building fire fighting action guide
1 Scope
This standard specifies the terms and definitions underground building fire fighting operations, general principles, fighting actions and the security.
This standard applies to firefighting force to underground building fire fighting action, a full-time fire brigade can be implemented by reference.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB 5907 Fire basic terms of the first part
GB/T 11651 Personal protective equipment selection specification
GB/T 18664 respirator selection, use and maintenance
GA 621 firefighters equipped with standard personal protective equipment
3 Terms and Definitions
GB 5907 defining the following terms and definitions apply to this document.
3.1
Underground construction undergroundbuilding
Built in soil or rock below the ground level elevation of the building, including the attached build underground buildings and single built underground construction.
3.2
Fire fighting plan firefightingplan
For fire fighting objects may occur, for fire fighting prearranged plan of action.
3.3
Tiered response gradedresponse
Fire fighting combat formation and strength seconded action by fire and emergency rescue grading regulations.
3.4
Cooperative Engagement coordinatedfirefighting
According headquarters of the unified deployment of the parties to the war power of the division responsible for cooperating operations.
3.5
Sports communication movementcommunication
Firefighters on foot or by vehicle passing communication instrument or order.
4 General
4.1 underground building fire fighting action should adhere to the "save first, scientific rescue" the guiding ideology.
4.2 underground building fire fighting action should follow "scenario support, tiered response; science smoke, ensure the communication; major breakthroughs, as reasonably attack"
in principle.
|