Basic data Standard ID | GA 654-2006 (GA654-2006) | Description (Translated English) | Standard for fire safety managenment of assembly occupancies | Sector / Industry | Public Security (Police) Industry Standard | Classification of Chinese Standard | C80 | Classification of International Standard | 13.220.20 | Word Count Estimation | 18,116 | Date of Issue | 2006-10-25 | Date of Implementation | 2007-01-01 | Quoted Standard | GB/T 5907; GB/T 14107; GB 50045; GB 50084; GB 50098; GB 50116; GB 50140; GB 50222; GBJ 16; JGJ 48; GA 503; GA 587 | Issuing agency(ies) | Ministry of Public Security | Summary | This standard stipulates the fire safety management requirements and measures for the use and management units of crowded places. This standard is applicable to all kinds of crowded places and their buildings fire safety management. |
GA 654-2006: Standard for fire safety managenment of assembly occupancies---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Standard for fire safety managenment of assembly occupancies
ICS 13.220.20
C80
People's Republic of China Public Safety Industry Standard
Fire safety management in crowded places
Released on October 16,.2006
2007-01-01 implementation
Ministry of Public Security
Content
Foreword III
Introduction IV
1 Scope 1
2 Normative references 1
3 Terms and Definitions 1
4 General 2
5 Fire safety responsibilities and duties 2
5.1 General 2
5.2 Responsibilities of property rights units, users or entrusted management units in crowded places 3
5.3 Fire Safety Responsibility 3
5.4 Fire Safety Manager's Responsibilities 3
5.5 Department Fire Safety Responsibility Responsibilities 3
5.6 Fire Control Room Duty Officer Duties 4
5.7 Firefighting Facilities Operation and Maintenance Personnel Responsibilities 4
5.8 Security personnel duties 4
5.9 Electrical welders, electricians, flammable and explosive chemicals operators responsibilities 4
6 Fire Fighting Organization 4
7 Fire safety system and management 4
7.1 General 4
7.2 Fire Safety Meeting 5
7.3 Fire inspection and inspection 5
7.4 Fire Propaganda and Training 5
7.5 Safety evacuation facility management 6
7.6 Fire Fighting Facilities Management 6
7.7 Fire hazard rectification 7
7.8 Electrical fire safety management 7
7.9 Safety management with fire and hot fire 7
7.10 Management of Flammable and Explosive Chemicals 8
7.11 Fire Safety Key Management 8
7.12 Fire Archives 8
8 Fire safety measures 9
8.1 General 9
8.2 Hostel 9
8.3 Store 9
8.4 Public entertainment venues 10
8.5 School 10
8.6 Hospital ward building, nursery school, kindergarten 10
8.7 Sports venues, exhibition halls, exhibition halls of museums, etc. 10
8.8 Personnel-intensive production and processing workshops, staff collective dormitory 10
9 Fire fighting and emergency evacuation plan preparation and exercise 11
9.1 Plan 11
9.2 Organization 11
9.3 Plan Implementation Procedure 11
9.4 Promulgation and improvement of the plan 11
9.5 Fire drill 12
10 Fire Accident Disposal and Aftercare 12
Reference 13
Foreword
4.4 to 4.7, 5.1.2, 6.5, 7.1, 7.5.2, 7.7, 7.10, 8.1.1, 8.1.3 of this standard , 8.2.2, 8.3, 8.4.1, 8.4.3~
8.4.5, 8.5, 8.6.1, 8.8, 10.1 to 10.4 are mandatory provisions, and the rest are recommended provisions.
This standard was proposed by the Fire Department of the Ministry of Public Security.
This standard is under the jurisdiction of the Ninth Technical Committee of the National Fire Protection Standardization Committee (SAC/TC113/SC9).
This standard was drafted. Fire Department of the Ministry of Public Security, Tianjin Fire Research Institute of the Ministry of Public Security.
The main drafters of this standard. Li Shuhui, Liu Jiyang, Yin Lige, Huang Zhenxing, Wang Zongcun, Song Xiaoyong, Luo Yunqing, Wu Dan, Ma Rui, Cai Wei,
Gao Jintian, Xue Duan, Yang Jigong, Xue Gang, Ni Zhaopeng.
Introduction
In recent years, fires and accidents have occurred in crowded and crowded places, causing serious losses to people's lives and property. For practical absorption
Lessons, standardize the fire safety management of such places, and curb the occurrence of mass casualties and fires, according to the "Fire Law of the People's Republic of China", etc.
Relevant laws and regulations, this standard puts forward corresponding fire safety management on the basis of research and analysis of personnel intensive places and their fire characteristics.
Requirements and measures to guide and regulate the fire safety management of such sites and improve their fire safety management.
Personnel intensive places can adopt this standard to regulate their own fire safety management behaviors, establish self-inspection of fire safety, and fire hazards
In addition, the self-management and restraint mechanism of firefighting responsibility is to prevent fires, reduce fire hazards, and protect personal and property safety.
purpose.
This standard is based on investigation and research, summarizing practical experience, reference and absorption of relevant information at home and abroad, and extensively soliciting opinions from multiple parties.
customized.
Fire safety management in crowded places
1 Scope
This standard proposes fire safety management requirements and measures for the use and management of personnel intensive places.
This standard applies to fire safety management of all types of densely populated places and their buildings.
2 Normative references
The terms in the following documents become the terms of this standard by reference to this standard. All dated references, followed by all
Modifications (not including errata content) or revisions do not apply to this standard, however, parties to agreements based on this standard are encouraged to study
Is it possible to use the latest version of these files? For undated references, the latest edition applies to this standard.
GB/T 5907 Basic Terms of Fire Protection Part 1
GB/T 14107 Basic Terms of Fire Fighting Part II
GB 50045 high-rise civil building design fire protection specification
GB 50084 automatic sprinkler system design specification
GB 50098 Civil Air Defense Engineering Design Fire Protection Code
GB 50116 Fire Automatic Alarm System Design Specification
GB 50140 Building Fire Extinguisher Configuration Design Specification
GB 50222 Building interior decoration design fire protection specification
GB J16 Building Design Fire Code
JGJ48 store building design specification
GA 503 Building Fire Protection Facilities Testing Technical Regulations
Maintenance and management of GA 587 building fire protection facilities
3 Terms and definitions
GB/T 5907, GB/T 14107, GB 50045, GB 50084, GB 50098, GB 50116, GB 50140, GB 50222,
GB J16, JGJ48, GA 503, GA 587 established and the following terms and definitions apply to this standard.
3.1
An indoor venue with cultural entertainment, fitness and leisure functions and open to the public. Including theaters, video halls, auditoriums, etc.
Places, dance halls, karaoke halls and other entertainment venues, entertainment nightclubs, music cafes, bars and dining venues, entertainment, play
Places, bowling alleys, roller skating rinks, saunas and other entertainment, fitness, leisure places and Internet access services.
3.2
An indoor place where people gather. Such as. hotels, restaurants and other hotels, restaurants, shopping malls, markets, supermarkets and other shops, stadiums, public exhibitions
Exhibition halls, museum exhibition halls, financial and securities exchanges, public entertainment venues, hospital outpatient buildings, ward buildings, elderly buildings, nurseries,
Kindergarten, school building, library and dormitory, reading room of public library, waiting for passenger station, dock, civil airport, waiting
Ships, waiting rooms (floors), intensive production and processing workshops, staff collective dormitories, etc.
3.3
Close to the building, the operating site for lifting fire trucks and implementing fire fighting and rescue.
|