US$879.00 ยท In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GA 503-2004: Testing code for fire protection systems Status: Obsolete
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GA 503-2004 | English | 879 |
Add to Cart
|
4 days [Need to translate]
|
Testing code for fire protection systems
| Obsolete |
GA 503-2004
|
PDF similar to GA 503-2004
Standard similar to GA 503-2004 GB/T 9978.1 GB/T 7633 GA/T 537
Basic data | Standard ID | GA 503-2004 (GA503-2004) | | Description (Translated English) | Testing code for fire protection systems | | Sector / Industry | Public Security (Police) Industry Standard | | Classification of Chinese Standard | C82 | | Classification of International Standard | 13.220.20 | | Word Count Estimation | 22,219 | | Date of Issue | 2004-06-09 | | Date of Implementation | 2004-10-01 | | Quoted Standard | GB 4717-1993; GB/T 4718-1996; GB 14003-1992; GB/T 14107-1993; GB 15322-1994; GB 15630-1995; GB 16806-1997; GB 16808-1997; GB 17429-1998; GB 50116-1998; GB 50263-1997; GA 95-1995 | | Summary | This standard specifies the technical requirements for the inspection and testing of fire-fighting installations in buildings and provides methods. This standard is applicable to the inspection and testing of building fire-fighting facilities. |
GA 503-2004: Testing code for fire protection systems---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Testing code for fire protection systems
ICS 13.220.20
C82
People's Republic of China Public Safety Industry Standard
Technical regulations for building fire protection facilities
Released on June 06,.2004
Implementation of.2004-10-01
Ministry of Public Security
Foreword
4.1 to 4.16 and 5.1 of this standard are mandatory provisions, and the rest are recommended provisions.
This standard was proposed by the Fire Department of the Ministry of Public Security.
This standard is under the jurisdiction of the Ninth Technical Committee of the National Fire Protection Standardization Committee (SAC/TC113/SC9).
This standard was drafted. Fire Department of the Ministry of Public Security, Tianjin Fire Research Institute of the Ministry of Public Security.
The main drafters of this standard. Li Shuhui, He Yishen, Liu Jiyang, Ding Yuping, Huang Fengmei, Sudan, Liu Yumei, Feng Aiquan.
Introduction
Building fire protection facilities set up in accordance with relevant national laws and regulations and national engineering construction fire protection technical standards are to prevent fires from occurring and timely
Effective measures to save the initial fire. In order to standardize the inspection and testing of building fire protection facilities, and ensure the normal operation of various fire protection facilities,
The current national fire protection technical standards, the development of this standard. For the construction fire protection facilities not covered by this standard, the inspection and testing may refer to this standard.
Related requirements are carried out.
Technical regulations for building fire protection facilities
1 Scope
This standard specifies the technical requirements for the inspection and testing of fire protection facilities in buildings and provides methods.
This standard applies to the inspection and testing of building fire protection facilities.
2 Normative references
The terms in the following documents become the terms of this standard by reference to this standard. All dated references, followed by all
Modifications (not including errata content) or revisions do not apply to this standard, however, parties to agreements based on this standard are encouraged to study
Is it possible to use the latest version of these files? For undated references, the latest edition applies to this standard.
GB 4717-1993 General technical conditions for fire alarm controller
GB/T 4718-1996 Fire alarm equipment terminology
GB 14003-1992 Technical requirements and test methods for linear beam smoke detectors
GB/T 14107-1993 Basic terminology for fire protection Part II
GB 15322-1994 Technical requirements and test methods for flammable gas detectors
GB 15630-1995 Fire safety sign setting requirements
GB 16806-1997 General technical conditions for fire-fighting linkage control equipment
GB 16808-1997 Technical requirements and test methods for flammable gas alarm controllers
GB 17429-1998 General technical conditions for fire display panels
GB 50116-1998 Design specification for automatic fire alarm system
GB 50263-1997 Specification for construction and acceptance of gas fire extinguishing systems
GA 95-1995 Fire Extinguisher Repair and Retirement
3 Terms and definitions
The following terms and definitions as defined in GB/T 4718-1996 and GB/T 14107-1993 apply to this standard.
3.1
A general term for facilities such as fire alarms, fire fighting, evacuation, fire separation, fire fighting and rescue operations installed in buildings and structures.
4 Technical requirements
4.1 General requirements
4.1.1 The components and equipment of each fire-fighting facility shall conform to the design and selection, and shall have a certificate of ex-factory product, and the fire-fighting product shall have compliance with the law.
Proof of market access rules. The extinguishing agent should be within the validity period.
4.1.2 The permanent nameplates and the signs of the components and equipment of each fire-fighting facility shall be complete and the symbols shall be clear.
Clear and color standards should be correct.
4.1.3 System components, equipment, pipelines, trunking, support and hangers, etc. shall be intact and free from rust. Equipment and piping shall be free of leakage, conductors and electricity.
Cable connection, insulation performance, grounding resistance, etc. should meet the design requirements.
4.1.4 Instruments and instruments used for testing shall be qualified according to the relevant provisions of the State.
4.2 Fire-fighting power distribution facilities
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GA 503-2004_English be delivered?Answer: Upon your order, we will start to translate GA 503-2004_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GA 503-2004_English with my colleagues?Answer: Yes. The purchased PDF of GA 503-2004_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|