FZ/T 01109-2011: Method for the calculation of productive power for ring-spinning cotton yarns
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
FZ/T 01109-2011English259 Add to Cart 3 days [Need to translate] Method for the calculation of productive power for ring-spinning cotton yarns Valid FZ/T 01109-2011

PDF similar to FZ/T 01109-2011


Standard similar to FZ/T 01109-2011

FZ/T 01118   GB/T 730   FZ/T 01093   FZ/T 08006   FZ/T 07031   

Basic data

Standard ID FZ/T 01109-2011 (FZ/T01109-2011)
Description (Translated English) Method for the calculation of productive power for ring-spinning cotton yarns
Sector / Industry Spinning & Textile Industry Standard (Recommended)
Classification of Chinese Standard W01
Classification of International Standard 59.080.01
Word Count Estimation 11,145
Date of Issue 2011-12-20
Date of Implementation 2012-07-01
Regulation (derived from) Ministry of Industry and Information Technology Bulletin 2011 No. 43
Issuing agency(ies) Ministry of Industry and Information Technology of the People's Republic of China
Summary This standard specifies the production of pure cotton yarn products off power consumption per unit of production standard terms and definitions, ring-spun cotton yarn production processes and calculation methods. This standard applies to the production of cotton spinning enterprises pure cotton yarn ring spinning off standard product power consumption per unit of production calculations, the calculation results as a measure of product consumption level between enterprises and analyze the basis for comparison. This standard does not apply to other new spinning products.

FZ/T 01109-2011: Method for the calculation of productive power for ring-spinning cotton yarns

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Method for the calculation of productive power for ring-spinning cotton yarns ICS 59.080.01 W01 People's Republic of China textile industry standards Ring-spun cotton yarn production of electricity calculation method Issued on. 2011-12-20 2012-07-01 implementation Ministry of Industry and Information Technology of the People's Republic of China released

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. The standard proposed by China Textile Industry Association. This standard by the National Technical Committee of Standardization Technical Committee printing and dyeing cotton textiles (SAC/TC209/SC2) centralized. This standard was drafted. Silk, Textile Co., Ltd., Ningbo Blum Textile Co., Ltd., Shijiazhuang Changshan Textile Co., Ltd., Zibo Lanyan Group Co., Ltd., Sanyang Textile Co., Ltd., Shanghai textile industry technical supervision, China Textile Industry Association. The main drafters of this standard. Wang Hongfa, Patriotic, Liang Shu flowers, Song Guiling, Ye Jian Chun, Wang Jing Yi, Cai Ji DPRK, FUEL whole scene carefully. Ring-spun cotton yarn production of electricity calculation method

1 Scope

This standard specifies the terms and definitions of pure cotton yarn production of standard products off the power consumption per unit of production, raw cotton yarn ring Production processes and calculation methods. This standard applies to products off the standard power consumption per unit of production calculation of pure cotton yarn ring spinning enterprises production, and its results can be As a measure of product analysis and comparison between the consumption level and enterprise basis. This standard does not apply to other new spinning products. This standard does not make a unified variety of products regulated by the provinces, municipalities and autonomous regions on their own.

2 Terms and definitions

The following terms and definitions apply to this document. 2.1 Cotton production of electricity powerforcottonspinningproduction In addition to electricity infrastructure, power consumption and other non-production of electricity, the electricity consumption for cotton yarn production process, in units of kilowatt-hours (kW · h). 2.2 The basic production of electricity powerforessentialproduction Directly used for electricity production process is divided into electricity before spinning, spinning power, automatic winding three basic electricity production of electricity. 2.3 Pure cotton Standard standardcottongreyyarns In carded cotton yarns 14.6tex (40s), combed cotton yarn 14.6tex (40s) were used as pure cotton carded, combed cotton yarn standard Quasi goods. 2.4 Electricity conversion rate conversionfactorofelectricityconsumption In this step, the power consumption per unit of production than with the standard in the process of power consumption per unit of production for products. 2.5 Off standard electricity consumption per unit of production conversionofstandardelectricityconsumptionforperunitoutput In electricity production and actual production of cotton yarn by the process of electricity equivalent to the standard rate, equivalent to the standard output calculated Product power consumption per unit of production (or "product electricity consumption").

3 ring pure cotton yarn production processes

Ring-spun cotton yarn processing sub-carded, combed. Each step of the process as follows. --- Carded cotton yarns steps of. spinning (Qing Hua, carding, drawing, roving), spinning, automatic winding. --- Combed cotton yarn step. before spinning (carding, and pre-strip, strip and roll, combing, drawing, roving), spinning, automatic winding.

4 ring spun cotton yarn off standard electricity consumption calculation method

4.1 pure cotton ring spinning off standard electricity consumption calculation range Off standard electricity consumption calculation range to limit the production of electricity, including the basic production of electricity, air conditioning (dust) and other auxiliary power